Skip to content
AkerminMeasure. Monitor. Improve. Compare Products
Learning Center

Thermal Camera vs Borescope: Seeing Heat or Seeing Inside

You have a problem you cannot see. One instrument shows where heat is leaking or building up, the other shows what is physically inside a wall, pipe or engine. They answer different questions, and buying the wrong one wastes both money and time.

As an Amazon Associate, Akermin earns from qualifying purchases. Product links on this page are affiliate links.

If the fault is a temperature anomaly you cannot see with your eyes, such as a hot joint, a cold draught or a missing insulation patch, you need a thermal camera. The MiLESEEY TR20 and the Bosch GTC600C both record a thermal image with a stated temperature reading, and the AMPBANK M192 turns a phone into the same kind of tool. If the fault is physical and hidden behind a surface, such as a crack, a blockage or a foreign object, you need a borescope such as the Soliluxelink articulating unit. Neither instrument replaces the other. A thermal camera cannot see through a wall; it sees the temperature of the wall. A borescope cannot measure temperature; it sees the surface it is pointed at.

What each instrument physically measures

A thermal camera measures infrared radiation emitted by a surface and converts it to a temperature map. It does not see through materials. It sees the temperature of the first opaque surface in its field of view. If a wall is colder at one patch because insulation is missing behind it, the camera shows that patch as a cold spot. The camera is reading the wall, not the cavity. The physics is straightforward: every object above absolute zero emits infrared, and the camera’s microbolometer array turns that radiation into a value per pixel. The listing for the MiLESEEY TR20 states a 320 by 240 detector and a noise equivalent temperature difference (NETD) of under 40 millikelvin, which means it can resolve temperature differences smaller than a twentieth of a degree. That sensitivity is what lets you see a faint stud pattern or a small water leak that has cooled a patch of ceiling.

A borescope is a camera on a cable. It has no thermal capability. It measures nothing. It shows you a lit image of whatever surface the lens is pointed at. The Soliluxelink articulating borescope uses a semi-rigid 16.4 ft cable that holds its shape, an IP67 camera head and eight adjustable LEDs. The value is physical access. You can push the head through a spark plug hole, down a drain or behind a cabinet and see the obstruction, the crack or the corrosion. The image is visible light, so you are seeing exactly what a tiny camera sees, not a temperature pattern.

The fault decides the tool, not the budget

The most common buying mistake is to treat these as alternatives at the same price point. They are not. Ask what the fault is made of. If the fault is a temperature difference, a thermal camera is the correct instrument. Examples: a circuit breaker that is warmer than its neighbours under load, a ceiling that is cold over a missing insulation batt, a radiator that is hot at the top and cold at the bottom, a window frame that is colder than the surrounding wall. In each case the surface temperature is the evidence, and a thermal camera records it in a single frame. The Bosch GTC600C stores up to 500 thermal images and allows voice notes, which matters when you are documenting a survey across many rooms and need to remember which image belongs to which wall.

If the fault is physical, a thermal camera will only show you a secondary effect, and often not a useful one. A blocked pipe may show a temperature difference if hot water is flowing and the blockage changes the surface pattern, but a crack in a plastic housing, a broken gear tooth or a nest in a vent will not reliably produce a thermal signature. That is when you need to see inside. The borescope inspection camera is the instrument for physical access. The Soliluxelink is an articulating model, which means the tip can be steered rather than just pushed, and that matters when the cavity turns a corner.

There is an overlap zone. A thermal camera can find a hot spot on a pipe, and a borescope can then be sent into the pipe to see the corrosion that caused it. The two instruments are complementary in a full diagnostic workflow. They are not substitutes.

Resolution, sensitivity and what the numbers actually mean

Thermal camera buyers fixate on pixel count, and it does matter, but sensitivity matters more for finding small anomalies. The MiLESEEY TR20 publishes 320 by 240 infrared resolution and NETD under 40 mK. The AMPBANK M192 publishes 192 by 192 native resolution with super-resolution processing to 384 by 384, and 40 mK sensitivity. The Bosch GTC600C does not publish its detector resolution or NETD in the listing bullets, so a buyer comparing on specification alone cannot place it on the same scale. That is not a criticism of the instrument; it is a limit of the published data. If detector resolution is the deciding factor for you, the listing does not give you the number.

What does resolution do in practice? A 320 by 240 detector gives 76,800 temperature pixels. A 192 by 192 detector gives 36,864. When you are looking at a wall from across a room, the higher-resolution detector puts more pixels on the suspect patch, so a small cold spot occupies more pixels and is easier to distinguish from noise. Super-resolution, as used on the AMPBANK M192, interpolates between measured pixels using motion or pattern data. It sharpens the display but does not create new temperature measurements. Treat it as a presentation improvement, not a sensitivity improvement.

Borescope resolution is simpler. The Soliluxelink states 1080P HD on a 4.3 inch IPS screen. That is visible-light resolution, and it tells you how much detail you can see on the surface you are inspecting. It says nothing about temperature. A borescope has no temperature measurement at all unless the listing explicitly states one, and this listing does not.

Where each instrument stops being the right answer

A thermal camera stops being useful when the surface you can see is not coupled to the fault. If a wall is covered by a cabinet, a thermal camera cannot see the wall. If a pipe is buried in concrete, the surface temperature at the floor may be too diffuse to localise the leak. If the fault is a loose connection inside a sealed enclosure, the heat may not reach the enclosure surface in a detectable pattern. In those cases the thermal camera is not wrong, it is just looking at the wrong surface. The honest answer is that you need access, and that means opening the enclosure or using a borescope.

A borescope stops being useful when the fault has no visible physical form. A borescope cannot tell you whether a wire is live, whether a joint is overheating or whether a wall is wet inside. It can show you discolouration or corrosion, but it cannot measure temperature or moisture. If you send a borescope into a cavity and see nothing, that does not mean the cavity is healthy. It means the fault is not visible in the illuminated image. That is the moment to switch to a thermal camera or a moisture meter.

Neither instrument is a safety device. A thermal camera is not a gas detector and does not measure carbon monoxide. A borescope is not a confined space monitor. If you are entering a space, you need the appropriate gas detection and entry procedures, not an inspection camera.

A practical comparison table

Instrument What it measures Access required Best for Key limit
MiLESEEY TR20 Surface temperature, 320×240 IR, NETD under 40 mK, range -4 to 1022 F, accuracy plus or minus 2 percent Line of sight to the surface Electrical hot spots, insulation gaps, HVAC imbalance Cannot see through covers or into cavities
Bosch GTC600C Thermal image, stores 500 images, voice notes Line of sight to the surface Documented surveys with spoken annotations Detector resolution and NETD not stated in the listing bullets
Soliluxelink articulating borescope Visible-light image, 1080P, 4.3 inch screen, IP67 head, 8 LEDs Physical entry into the cavity Blockages, cracks, corrosion, foreign objects No temperature measurement
AMPBANK M192 Surface temperature, 192×192 native to 384×384 super-resolution, 25 Hz, 40 mK, range -4 to 842 F Line of sight to the surface, plus a USB-C phone or tablet Phone-based thermal surveys, quick checks Requires a host device; not compatible with Mac

The table makes the split clear. The two thermal cameras and the phone module answer a temperature question. The borescope answers a physical access question. The only row where the limit is about published data rather than physics is the Bosch, and that is a reason to ask the manufacturer for the missing figures before you buy on specification.

How to decide in the shop

Decide what evidence would prove your hypothesis. If the evidence is a temperature difference on a surface you can see, buy a thermal camera. If the evidence is a physical feature inside a cavity you cannot see, buy a borescope. If you need both, buy the one that matches the first fault you expect to meet, and add the other when the work justifies it. Do not buy a thermal camera to look inside a wall, and do not buy a borescope to find a hot joint. They are different senses, and the fault tells you which sense you need.

Frequently Asked Questions

Can a thermal camera see through walls?

No. A thermal camera reads the temperature of the first opaque surface in front of it. It can show a cold patch on a wall caused by missing insulation behind it, but it cannot show the cavity itself. If you need to see inside the cavity, you need a borescope or physical access.

Can a borescope measure temperature?

Not unless the listing explicitly states a temperature measurement function. The Soliluxelink articulating borescope in this comparison does not publish a temperature range or accuracy, so treat it as a visible-light inspection tool only. A borescope shows you what a camera sees, not how hot it is.

Which is better for finding a water leak?

A thermal camera is often the faster tool because evaporating water cools the surface around the leak, creating a cold anomaly. But the camera only sees the surface. If the leak is behind a sealed panel or inside a pipe, the thermal signature may not reach a visible surface, and a borescope may be needed to inspect the cavity directly. Neither instrument confirms moisture content; a moisture meter does that.

Do I need both instruments?

Only if your work regularly produces both kinds of fault. An electrician diagnosing hot joints can work with a thermal camera alone. A plumber clearing blockages can work with a borescope alone. A building surveyor who documents insulation defects and also inspects cavities will eventually want both, but buying both at once is rarely necessary for a single fault.

Is a phone thermal camera as good as a dedicated thermal camera?

The AMPBANK M192 publishes 192 by 192 native resolution with super-resolution to 384 by 384, 25 Hz and 40 mK sensitivity. The MiLESEEY TR20 publishes 320 by 240 native resolution and under 40 mK. On the published figures the dedicated unit has more native pixels, which helps when resolving small targets at distance. The phone module wins on portability and on using a screen you already carry. Whether the difference matters depends on the size of the target and the distance you work from.

What does NETD mean and why does it matter?

NETD is noise equivalent temperature difference, a measure of the smallest temperature change the detector can distinguish from its own noise. A lower number means better sensitivity. The MiLESEEY TR20 and the AMPBANK M192 both state 40 mK, which is a good figure for general inspection work. The Bosch GTC600C does not state NETD in the listing bullets, so it cannot be compared on that figure from the published data alone.