Skip to content
AkerminMeasure. Monitor. Improve. Compare Products
Learning Center

Can a CO2 Detector Detect CO?

You own a carbon dioxide monitor and wonder whether it also protects you from carbon monoxide, or you are deciding which one to buy. The gases sound alike, but the sensors are completely different.

As an Amazon Associate, Akermin earns from qualifying purchases. Product links on this page are affiliate links.

A CO2 detector cannot detect CO and should never be relied on for it. Carbon dioxide monitors use an infrared sensor tuned to the wavelength CO2 absorbs, and carbon monoxide absorbs at a different wavelength, so it is effectively invisible to them; the dangerous level of CO is also tiny, tens to hundreds of ppm, against CO2 readings in the thousands. Cheaper estimated-CO2 monitors may twitch when CO is present, but not reliably or at the right levels. Any home with fuel-burning appliances, an attached garage or a generator needs a listed carbon monoxide alarm in addition to any CO2 monitor.

Two gases, two jobs

Carbon dioxide (CO2) is the gas we exhale and the product of complete combustion. Indoors, its level mainly tells you how well a room is ventilated. Outdoor air contains a little over 420 ppm, and occupied rooms commonly run from 600 to 2,000 ppm. It becomes a direct health hazard only at much higher concentrations, around 5,000 ppm for long workplace exposure and above.

Carbon monoxide (CO) comes from incomplete combustion in boilers, furnaces, stoves, fireplaces, generators and vehicles. It is poisonous at very low concentrations, because it binds to haemoglobin and blocks oxygen delivery. Prolonged exposure at a few tens of ppm causes symptoms in many people, and a few hundred ppm can be life-threatening within hours.

Those numbers show why one sensor cannot do both jobs. A CO2 monitor’s normal range spans thousands of ppm with an accuracy of perhaps tens of ppm; a CO hazard is a few dozen extra molecules per million of a completely different gas. The basics are on what CO2 is and why it matters.

Why the sensor ignores carbon monoxide

Most good CO2 monitors use NDIR sensing. A small infrared source shines through a chamber of sampled air onto a detector behind an optical filter. The filter passes only a narrow band around 4.26 micrometres, where CO2 molecules absorb strongly. More CO2 means less light reaches the detector.

Carbon monoxide absorbs infrared at around 4.6 micrometres, outside that filter’s band. So CO passing through the chamber barely changes the signal. That selectivity is the reason NDIR CO2 sensors are accurate: water vapour, perfume and most other gases do not fool them either. The same feature means they are blind to CO. The full mechanism is explained in how CO2 monitors work.

Device Sensor Detects CO2? Detects CO?
NDIR CO2 monitor Infrared, CO2 band Yes, accurately No
eCO2 air quality monitor Metal-oxide gas sensor Estimates only May react, unreliably; not a safety device
Household CO alarm Electrochemical CO cell No Yes, to a safety standard
CO meter for technicians Electrochemical CO cell No Yes, with live readings
Combination monitor with both sensors NDIR plus electrochemical Yes Yes, if the CO part is listed as an alarm
Natural gas or propane detector Catalytic or metal-oxide No Only if it has a separate CO sensor

Electrochemical CO cells are selective in the other direction. They oxidise carbon monoxide at an electrode, and carbon dioxide, being already fully oxidised, does not react. So a CO alarm stays at zero in a crowded, stuffy room, and a CO2 monitor stays calm during a dangerous CO leak. Each instrument is good precisely because it ignores the other gas.

What about estimated CO2 monitors?

Many inexpensive air quality monitors display eCO2 or equivalent CO2. These use a heated metal-oxide sensor that responds to a broad mix of reducing gases, then convert the signal into a CO2-like number using assumptions about how much exhaled breath accompanies the volatile compounds people give off. The difference is set out in NDIR vs metal-oxide CO2 sensors.

Because metal-oxide sensors respond to many gases, carbon monoxide can nudge the reading. But the response is not calibrated, not specific, and is swamped by cooking, cleaning products and alcohol. A rising eCO2 number could be a CO leak, a cup of coffee being brewed, or hand sanitiser. These devices are not tested to any carbon monoxide safety standard and do not sound at the time-weighted thresholds CO alarms follow. Treat them as air quality indicators only.

How to tell what your device actually measures

  1. Read the label and the box. A CO alarm says carbon monoxide alarm and, in North America, usually carries a UL 2034 listing; in Europe, EN 50291. A CO2 monitor says carbon dioxide or CO2.
  2. Look at the display. A CO2 monitor shows hundreds or thousands of ppm all the time. A CO alarm usually shows zero or nothing until CO is present.
  3. Check the sensor type in the manual or listing. NDIR means CO2. Electrochemical usually means CO. MOX or metal-oxide with eCO2 means an estimate.
  4. Look for both on combination units. Some smart air monitors include a separate CO sensor; confirm that part is certified as an alarm, not just a reading.

For instance, a monitor like the VETOUCH 3-in-1 CO2 monitor or the SwitchBot CO2 detector is designed to track carbon dioxide, temperature and humidity; it is not a CO alarm. A dedicated CO alarm is a separate purchase.

What to install, and where

  • A listed CO alarm on every level of the home and outside each sleeping area, kept a few metres from fuel-burning appliances, and replaced at the end of its rated life, usually 5 to 10 years from manufacture.
  • A CO2 monitor where ventilation matters: bedrooms, home offices, classrooms, meeting rooms, grow rooms. Use NDIR for numbers you can trust; the guide on choosing a CO2 monitor for home use covers what to look for.
  • A combustible gas detector if you want warning of natural gas or propane leaks, which neither CO nor CO2 sensors provide.

If a CO alarm ever goes into full alarm, typically four loud beeps and a pause, leave the building with everyone, call emergency services or your gas utility from outside, and do not return until it has been checked. If several people feel headache, dizziness or nausea at home that eases outdoors, treat it as possible CO exposure even if your CO2 monitor looks normal; a normal CO2 reading says nothing about carbon monoxide.

A practical pairing for a typical home looks like this: sealed 10-year CO alarms in the hallway outside the bedrooms and one on each other level including the basement, and one NDIR CO2 monitor in the room where people spend the most time with the door shut, usually the main bedroom or the home office. The CO alarms stay silent for years if all is well, which is how they should behave. The CO2 monitor changes all day, and its job is to remind you to open a window, not to save your life.

Check what is on your wall

Pick up each gas device in your home today and read its label. If none of them says carbon monoxide and you have any gas, oil, wood or charcoal appliance, an attached garage, or use a generator, buy a listed CO alarm for each level and each sleeping area this week, and keep your CO2 monitor for what it does well: telling you when to open a window.

Frequently Asked Questions

Is a carbon dioxide detector the same as a carbon monoxide detector?

No. They detect different gases with different sensors and serve different purposes. A CO2 monitor tracks ventilation; a CO alarm protects against poisoning from combustion appliances.

Will a CO2 monitor show a high reading during a CO leak?

Not because of the CO. A faulty appliance might also release extra CO2, so the reading could rise somewhat, but that is not a reliable warning and many CO leaks would go unnoticed.

Can a carbon monoxide alarm detect CO2?

No. Electrochemical CO cells are designed to respond to carbon monoxide and ignore carbon dioxide. If you want to monitor ventilation, you need a separate CO2 monitor.

Are there devices that detect both?

Yes, some combination monitors contain an NDIR CO2 sensor and an electrochemical CO sensor. Check that the CO function is certified as an alarm before relying on it for safety.

Do I need a CO2 monitor if I have a CO alarm?

Not for safety in a typical home. A CO2 monitor is optional and useful for comfort and ventilation, while a CO alarm is the essential safety device wherever fuel is burned.