You are weighing up solar, or your existing panels seem to be producing less than they used to, and you want to know how much to trust the technology. The cells themselves are very dependable, but the system around them has weak points worth knowing.

As an Amazon Associate, Akermin earns from qualifying purchases. Product links on this page are affiliate links.

Yes, PV cells are among the most reliable parts of any home energy system. Crystalline silicon modules have no moving parts, lose output slowly, commonly around half a percent a year, and are usually backed by performance warranties lasting decades. When a solar system underperforms, the cause is far more often dirt, shading, a failed connector, a cracked cell from impact or handling, or an inverter fault than the cells simply wearing out. You can check a panel’s health by measuring its open-circuit voltage and short-circuit current against the label, or with an I-V curve tracer, and a thermal camera reveals hot spots that point to damaged cells.

Why a solar cell lasts so long

A PV cell is a thin wafer of silicon treated so that one side is rich in electrons and the other is short of them, forming a junction. When light hits it, photons free electrons, and the junction pushes them out through the metal contacts as direct current. Nothing moves, heats much beyond the panel’s operating temperature, or gets consumed. That is the basic reason cells are so durable.

The module around the cells is what protects that durability: a glass front, an encapsulant layer that bonds the cells to the glass, a backsheet or second glass layer, an aluminium frame, and a junction box with bypass diodes. Most long-term ageing happens in these layers. Ultraviolet light slowly yellows some encapsulants, moisture can creep in at edges over many years, and repeated heating and cooling stresses the soldered ribbons between cells. Manufacturers usually guarantee that output will remain above a stated percentage of its original rating after a long period, which reflects how gradual this ageing is.

What actually goes wrong in the field

Problem How it shows up Typical cause Fix
Soiling Gradual loss, worse in dry dusty seasons Dust, pollen, bird droppings Clean following the maker’s guidance
New shading Sharp drop at certain times of day Tree growth, new building, aerial Trim, relocate, or add module-level electronics
Connector or cable fault One string low or dead, possibly scorch marks Poorly crimped or mismatched connectors, water ingress Installer replaces connectors
Cracked cells Hot spots on a thermal image, reduced current Hail, foot traffic, rough handling Panel replacement if loss is significant
Bypass diode failure Voltage about a third low on one panel Heat, lightning surges Junction box repair or panel replacement
Potential induced degradation Panels at one end of a string lose output Voltage stress in some system designs Installer diagnosis, sometimes reversible
Delamination or browning Visible bubbles or discoloured patches Encapsulant ageing, manufacturing defect Warranty claim
Inverter fault Whole system low or off, error code Electronics ageing, heat Inverter repair or replacement

Inverters are the component most likely to need replacing during a system’s life, because they contain capacitors and power electronics that age with heat. Monitoring the inverter’s daily output is the simplest early warning for everything in the table. Why solar panel output changes during the day explains which variations are normal.

Checking a panel’s health yourself

For a single panel or a small off-grid system you can access safely at ground level, two basic measurements reveal most faults.

  1. Read the label. Note the rated open-circuit voltage (Voc), short-circuit current (Isc), and the voltage and current at maximum power.
  2. Disconnect the panel from its controller or load using the system’s isolator, in line with the installer’s instructions.
  3. Measure Voc with a multimeter rated for the DC voltage involved. On a clear day, a healthy panel reads close to its label value, a little lower when hot, because silicon cell voltage falls by roughly a third of a percent for every degree Celsius above the rating temperature.
  4. Measure Isc only if your meter’s current range is fused above the panel’s label Isc, or with a DC clamp meter around a rated shorting lead. Make and break the short with the panel covered or through a rated DC switch, never by pulling a probe under load, because breaking DC current draws an arc. Current scales with sunlight, so a reading of about 80 percent of the label under bright midday sun is in the right range.
  5. Compare panels. Identical panels in the same sun should read within a few percent of each other. One far below the rest points to that panel.

The difference between Voc and working voltage often confuses people; open-circuit versus operating voltage covers it, and how to measure solar panel output gives the full procedure.

Going deeper: I-V curves and thermal images

Spot readings miss some faults. An I-V curve tracer sweeps the panel from short circuit to open circuit and plots the full current-voltage curve. Steps or dips in the curve reveal shaded or cracked cells and failed bypass diodes, and comparing the measured maximum power with the rated value, corrected for sunlight and temperature, shows how much the panel has degraded. Handheld analysers such as the PROVA 218 PV Analyzer list I-V curve testing and readings of voltage and current at maximum power. Professional installers use multifunction testers like the Fluke SMFT-1000, which is described as meeting IEC 62446-1 for system commissioning tests and can compare on-site curves with the manufacturer’s data.

A thermal camera pointed at a panel working under good sun shows cracked cells, bad solder joints and failing diodes as warmer patches, because damaged areas dissipate power as heat instead of passing it on. Measure from the ground or a safe position; never walk on panels.

Sunlight strength matters for every comparison. Readings taken under thin cloud can look like a fault when they are not; solar irradiance versus panel output explains how to account for it.

Safety limits and when to call the installer

Solar panels generate voltage whenever light falls on them. You cannot switch a panel off in daylight, and a string of panels on a home roof can produce several hundred volts DC, which is more dangerous than household AC because a DC arc does not self-extinguish easily. Rules to follow:

  • Do not unplug solar connectors under load; a DC arc can burn and start fires. Use the system’s isolator first.
  • Do not climb onto a roof to test panels. Rooftop and grid-connected systems are a job for a qualified solar installer or electrician.
  • Use only meters and leads rated for the DC voltage and category involved.
  • Scorch marks, melted connectors, a burning smell, or an inverter showing an earth or insulation fault are reasons to isolate the system if you can do so safely and call the installer promptly.

If a panel is under warranty and you have measurements showing it far below its siblings, photograph the label, note the readings, the weather and the time, and pass them to the installer. That record makes a warranty claim much easier.

Start with your inverter data

Open your inverter or monitoring app and compare this month’s output with the same month in earlier records, on a few similarly sunny days. A small steady decline is normal ageing; a sudden step down points to shading, soiling, a connector or one damaged panel, and that is when the measurements above are worth doing or booking.

Frequently Asked Questions

How long do PV cells last?

Well-made crystalline silicon modules are designed for decades of service, and performance warranties commonly run for a similar period. They usually keep producing beyond that at a reduced level rather than failing suddenly.

How much do solar panels degrade each year?

Typical crystalline silicon modules lose somewhere around half a percent of output per year, with some faster in the first year. The exact figure is in the panel's warranty and datasheet.

Can hail destroy solar cells?

Panels are tested for hail impact and usually survive ordinary hail. Very large hail can crack glass or cells, which shows up as hot spots on a thermal image or lower current from that panel.

Do solar cells work less well when hot?

Yes. Cell voltage falls as temperature rises, so panels often produce less power on a scorching day than on a cool bright one. This is normal physics, not a fault.

What fails first in a solar system?

The inverter is usually the first major component to need replacement, followed by connectors and cabling issues. The cells themselves are typically the most durable part.