As an Amazon Associate, Akermin earns from qualifying purchases. Product links on this page are affiliate links.

KLEIN TOOLS · Klein Tools CL445 HVAC Clamp Meter, Auto-Ranging | TRMS, NCVT, Measures Voltage, Current, Temperature, Micro Amps, InRush and More
View on AmazonPrice and availability are shown on Amazon and can change at any time.
An auto ranging True RMS clamp meter sold for heating and cooling work. Through the jaw it reads alternating current, captures inrush and detects voltage without contact. Through the test leads it reads AC and DC voltage, resistance, continuity, frequency, duty cycle, DC microamps, diode drop and capacitance, and through a thermocouple it reads temperature. The dual backlit display shows volts and amps together. The function that justifies the HVAC label is the DC microamp range, and it is buried mid sentence. Not a single range, accuracy or category figure appears anywhere in the bullets.
Microamps is a furnace measurement hiding in a list
The first bullet is one enormous sentence. Inside it, between diode test and capacitance, sit two words that most buyers will skim past: DC microamps.
That range exists for one job above all others. A gas furnace proves its flame electrically. The flame itself conducts between the sensor rod and the grounded burner, and because the conduction is asymmetric it rectifies the alternating signal the board applies, so what returns is a small direct current. The control board watches that current and keeps the gas valve open only while it is there.
The current is tiny, in millionths of an amp. A layer of oxide on the sensor rod, a weak flame, a poor burner ground or a drifting board will all pull it down, and when it falls below what the board wants the appliance locks out. To the homeowner that is an intermittent fault. To anyone with a microamp range it is a number you read and compare.
No other function on this meter is as specific to the work. Current, voltage, resistance and capacitance appear on every clamp meter sold. A microamp range on the direct current side appears on meters designed by someone who has stood in front of a furnace at the fourth call back. Our guide on choosing a clamp meter for HVAC treats it as a gating feature for exactly that reason.
Capacitance belongs in the same conversation. Run and start capacitors on compressors and condenser fans fail gradually, and a measured microfarad figure against the one printed on the can is a direct verdict rather than an inference from how the motor sounds.
The first bullet quietly sorts functions by what has to be in your hand
Most listings in this category print one undifferentiated pile of measurements. This one groups them by how you take the reading: via clamp, via test leads, via thermocouple.
That structure is more useful than it looks, because it tells you what the jaw alone can do. Walk up to running equipment with nothing connected and you can clamp a conductor for current, capture inrush on a start, and sweep for live wires. Everything else on the list needs leads on metal, which means either the equipment is off or you are making a deliberate contact decision.
It also tells you, by omission, what the jaw cannot do. Direct current does not appear under the clamp, or anywhere else in the bullets. A reader who assumed an HVAC clamp meter reads DC amps around a conductor will find nothing on this page supporting it.
And the thermocouple line is honest in the same quiet way. Temperature is listed as arriving via thermocouple, which signals a plug in bead probe rather than an infrared spot on the body. A bead in an air stream reads the air. An infrared window on the case reads whatever surface it is aimed at, which on a duct is the sheet metal and not the air inside it. For measuring supply and return temperatures across a coil, the contact probe is the right answer.
Inrush is a different measurement from current
An ordinary current reading is an average over a window long enough to produce a stable display. That is exactly what you want on a running system and exactly what you cannot use on a starting one.
When a motor or a compressor starts, it is momentarily a near short circuit with windings and no rotation. Current rushes in until the rotor is turning fast enough to generate an opposing voltage. The surge can be a multiple of the running figure and it collapses within a fraction of a second, long before an averaging display settles.
An inrush mode changes the instrument into a trigger and a latch. It waits for current to appear, samples the first short window, and holds the result for you to read after the event. The difference in diagnosis is substantial. A compressor with a failing start capacitor, a stiff bearing or a locked rotor shows it in the starting current rather than the running current, and a breaker that nuisance trips on start tells you nothing while the unit is running happily. We collect the options in our guide to clamp meters with inrush capture.
A full function list with no numbers attached
| Item | Published in the listing |
|---|---|
| Readings via the jaw | AC current, inrush, non contact voltage detection |
| Readings via the leads | AC and DC voltage, resistance, continuity, frequency, duty cycle, DC microamps, diode test, capacitance |
| Readings via accessory | Temperature by thermocouple |
| Ranging | Auto ranging |
| Measurement type | True root mean square |
| Display | Backlit, voltage and current shown simultaneously |
| Hands free options | Side test lead holder, magnetic hanger as catalogue number 69445 or 69417 |
| AC current range | Not stated in the listing bullets |
| Voltage range, AC or DC | Not stated in the listing bullets |
| Inrush capture window | Not stated in the listing bullets |
| Microamp range and resolution | Not stated in the listing bullets |
| Capacitance range | Not stated in the listing bullets |
| Temperature span | Not stated in the listing bullets |
| Accuracy, any function | Not stated in the listing bullets |
| Measurement category rating | Not stated in the listing bullets |
| Jaw opening | Not stated in the listing bullets |
| Power source | Not stated in the listing bullets |
This is an unusual shape of listing. The function list is thorough to the point of being hard to read, and then not one quantity is attached to any of it. You know the meter measures capacitance. You do not know up to how many microfarads, which decides whether it can check a compressor run capacitor at all.
The absence that matters most is the category rating, because unlike the others it is a safety figure rather than a capability figure. A category rating describes how far up an installation the instrument is designed to survive a transient overvoltage, and the right figure depends on whether you are at a plug, at a distribution board, or at the service entrance. Our explainer on measurement category ratings sets out why the number and the voltage have to be read together. Get it from the datasheet before this goes into a live panel.
One published detail deserves credit for being checkable rather than vague. The magnetic hanger is identified by catalogue number, as an optional accessory, which is a specific and verifiable statement. Compare that with the usual formula of describing a tool as professional grade.
The technician this fits, and the one it will frustrate
The function set is aimed squarely at gas heating and air conditioning service. Microamps for flame proving, capacitance for motor capacitors, inrush for starting faults, thermocouple temperature for air across a coil, frequency and duty cycle for variable speed control signals, and a non contact sensor in the jaw so the first move at a unit is a safe one. The simultaneous volts and amps display suits watching a running system rather than taking one reading at a time.
It will frustrate two people. Anyone whose work includes direct current circuits will find no DC current function listed, which on a growing share of equipment is a genuine gap. And anyone who sizes instruments from a specification table will get nowhere with these bullets, because they contain no table to size from. Treat the page as a statement of what the meter does and go elsewhere for how far it does it.
Recommended Tools
Products shown because their documented specifications fit this guide. Price and availability are on Amazon and can change.
Frequently Asked Questions
Why does an HVAC meter need a DC microamp range?
Because that is the scale a gas furnace flame signal lives on. A flame conducts a tiny current between the sensor rod and the burner assembly and rectifies it, so the control board sees a small direct current when the flame is present and nothing when it is not. The board decides whether to keep the gas valve open on the strength of that signal. Measuring it in series with the flame sensor lead tells you whether a nuisance lockout is a dirty sensor, a weak flame, a bad ground or a failing board, and the units involved are millionths of an amp.
Can the jaw measure DC current?
The bullets list AC current, inrush and non contact voltage detection under the clamp, and list no DC current function anywhere on the page. So on the published information the jaw is for alternating current. That is worth knowing before buying for work on any circuit where the current you want is direct, because a jaw that cannot read it leaves you breaking into the circuit with a different instrument.
What is inrush and why does it need its own mode?
Inrush is the brief surge a motor or compressor draws in the instant it starts, before it is turning fast enough to generate back electromotive force to oppose the supply. It can be several times the running current and it is over in a fraction of a second, so an ordinary averaging display never shows it. An inrush mode arms the meter to capture and hold that first window. It is how you tell whether a breaker is tripping because the motor is dragging on start or because the circuit is simply undersized.
What does True RMS change in practice?
True root mean square measurement calculates the heating equivalent of a waveform whatever shape it is. A cheaper averaging meter is calibrated on the assumption that it is looking at a clean sine wave and reads low on anything else. Modern air conditioning equipment is full of switching electronics that distort the current waveform badly, so on an HVAC meter a True RMS front end is not a luxury feature, it is the difference between a reading and a guess.
What is the non contact voltage function inside the jaw for?
It senses the alternating field around a live conductor without touching metal, so you can confirm a wire is energised before you commit to putting probes on it. Building it into the clamp jaw rather than the body means the first thing you bring near the conductor is the sensor, which fits the order you actually work in. It is a presence indicator and not a measurement, so it tells you live or not live, never how many volts.
What measurement category is it rated to?
Not stated in the listing bullets, and neither is any voltage range, current range, jaw opening, accuracy figure or temperature span. The bullets are a complete function list with no numbers attached to any of it. For a meter going into live equipment, the category rating is the figure that describes where in an installation the instrument is built to survive a transient, so find it on the datasheet before deciding.
Affiliate disclosure: Akermin earns a commission from qualifying Amazon purchases made through links on this page. Our editorial picks are based on documented specifications and owner feedback, not commissions.