It depends on the job. A thermistor used to measure temperature carries a tiny current and should warm itself by only a fraction of a degree; if it gets noticeably hot, the circuit is wrong. Power thermistors are different: an NTC inrush current limiter in a power supply runs hot continuously, often too hot to touch, because its low resistance depends on staying warm, and PTC heater elements and resettable fuses heat up by design. A thermistor that is discoloured, cracked, smells burnt or is hotter than its neighbours in a measurement circuit is a fault and the equipment should be powered down.
Self-heating: the physics behind it
A thermistor is a resistor, so any current through it produces heat equal to current squared times resistance. That heat raises its temperature until it loses heat to its surroundings as fast as it is produced. The datasheet figure that captures this is the dissipation constant, in milliwatts per degree Celsius: how much power it takes to raise the thermistor 1 °C above its surroundings.
The temperature rise is simply the power divided by the dissipation constant. Small epoxy beads in still air often have dissipation constants on the order of one or a few milliwatts per degree; the same bead in moving air or stirred liquid sheds heat much faster.
Worked example: a 10 kilohm measuring thermistor sits in a divider with a 10 kilohm resistor across 5 V. At 25 °C the current is 5 V divided by 20,000 ohms, 0.25 mA. Power in the thermistor is 0.00025 squared times 10,000, about 0.6 mW. With a dissipation constant of 1.5 mW per °C, it warms by about 0.4 °C. With the divider fed from 3.3 V, the power is less than half and so is the error. That is why measurement circuits keep current low, and why our article comparing thermocouples and thermistors lists self-heating as one of the thermistor’s few drawbacks.
Which thermistors are meant to run hot
| Type | Where you find it | Normal temperature in use | Why |
|---|---|---|---|
| NTC measuring thermistor | Thermostats, probes, fridges, battery packs | Same as its surroundings, within a fraction of a degree | Tiny current |
| NTC inrush current limiter | Mains input of power supplies, motor drives, lamps | Hot, often well above boiling at full load | Must stay hot to keep resistance low |
| PTC resettable fuse | USB ports, battery packs, speaker lines | Near ambient normally, hot when tripped | Heats itself into high resistance on overload |
| PTC heater element | Small fan heaters, hair dryers, defrost and seat heaters | Hot, self-limiting at its design temperature | Resistance climbs steeply at a set temperature |
| PTC motor starter or degaussing element | Fridge compressors, older CRT displays | Hot after start, stays warm | Heats to switch itself out of circuit |
The inrush limiter is the one people most often find hot. When a power supply is switched on, its capacitors would draw a huge surge. A cold NTC disc has a few ohms of resistance and limits that surge. Current then heats the disc, its resistance falls to a fraction of an ohm, and it wastes little power. It stays hot for as long as the equipment runs. Datasheets for these parts list maximum operating temperatures far above what is comfortable to touch.
Checking whether the heat you see is normal
Before touching anything inside equipment, unplug it. Many power supplies hold dangerous voltage on capacitors after being switched off, and the inrush limiter sits right beside the mains input.
- Identify the part. A disc marked with a resistance and current code near the mains input is usually an inrush limiter. A small bead on a pair of fine wires taped to a pipe, battery or heatsink is a sensor.
- Look before measuring. Discolouration of the board around it, cracked coating, bulging, a burnt smell or melted sleeving are signs of overheating beyond its rating.
- Measure without contact. With the equipment running in its normal enclosure and covers fitted, an infrared thermometer or thermal camera through a vent or on an external surface shows whether one part is much hotter than its neighbours. For small parts, a thermocouple probe gives a truer reading than IR.
- Compare with the rating. The part’s datasheet gives its maximum operating temperature. An inrush limiter running near that limit at normal load suggests it is undersized, the cooling is blocked, or the equipment is drawing more current than it should.
- For a sensor, compare with ambient. If a measuring thermistor reads several degrees above a reference thermometer in still air but agrees in a stirred water bath, self-heating is the likely cause. Lower the current or allow airflow.
When a hot thermistor means a fault
- Inrush limiter cracking or burning. Common causes are switching on and off repeatedly before it cools, which removes its protection, a shorted component downstream drawing too much current, or blocked ventilation. Replace it with the same rating and find the cause.
- PTC fuse tripping repeatedly. A resettable fuse that gets hot and cuts out is doing its job: something is drawing too much current. Remove the load and look for a short or a failing device before resetting.
- PTC heater with uneven or very high temperature. The self-limiting element may have degraded or its airflow is blocked. Unplug and have the appliance checked.
- Measuring thermistor running warm. The circuit is pushing too much current, or the wrong part has been fitted. Self-heating error rises with the square of voltage.
- Battery pack thermistor reading high. Believe it until proven otherwise. A hot lithium battery is a fire risk; stop charging, move it away from combustibles if safe, and follow the device maker’s safety guidance.
Also remember that sensors need time to settle after being moved or powered; a slow approach to the final reading is not self-heating. Our note on why temperature sensors need time to stabilise explains how to tell the difference.
Keeping self-heating out of your own readings
If you are building or calibrating a thermistor measurement, a few habits keep the error negligible:
- Use the highest resistance thermistor and divider resistor that the input circuit can read accurately; current falls as resistance rises.
- Power the divider from a lower voltage, or switch it on only during each reading.
- Mount the sensor in good thermal contact with what it measures, using thermal paste or a well, rather than hanging in still air.
- When calibrating, use a stirred liquid bath so the sensor’s own heat is carried away.
- Check the datasheet’s dissipation constant and work out the expected rise; aim for well under the accuracy you need.
Identify the part before you worry
Unplug the equipment, find the hot component, and read its markings or look up the board’s parts list to see whether it is an inrush limiter, a PTC device or a measuring sensor. If it is a power thermistor with no discolouration and the equipment works normally, the heat is expected; if it is a sensor or shows burn marks, treat it as a fault and fix the cause.
Frequently Asked Questions
Is it normal for the NTC near my power supply input to be very hot?
Yes. Inrush current limiters run hot continuously because their low resistance depends on staying warm. It should not be discoloured, cracked or smelling burnt, and the rest of the supply should run normally.
Can a hot thermistor start a fire?
A correctly rated part in good equipment should not. An overloaded inrush limiter or a failing PTC heater can overheat surrounding materials, so burn marks or a smell of hot plastic mean the equipment should be unplugged and repaired.
Does self-heating make a thermometer read high?
Slightly. A typical measurement circuit adds a fraction of a degree in still air and less in moving air or liquid. Good designs keep the current low enough that the error is smaller than the sensor's accuracy.
Why does an inrush limiter need time to cool before switching back on?
Its protection works only when it is cold and high in resistance. Switching on again while it is still hot lets the full surge through, stressing the limiter and other components.
How do I measure the temperature of a small thermistor safely?
Keep the covers on and use an infrared thermometer or thermal camera through a vent or on the outside of the enclosure, or have a technician fit a thermocouple probe. Never reach into live mains equipment.