First work out which meter you have. A bidirectional net meter fitted by the utility scrolls through several registers, usually one for energy imported from the grid and one for energy exported, both in kWh; note both and subtract last month’s values to get this month’s figures. A separate generation meter or the inverter display shows the total kWh your panels have produced, which you can compare with a rough expected figure of system size times peak sun hours times about 0.75. A handheld solar power meter shows sunlight intensity in W/m2, which tells you how much light is reaching the panels, not how much electricity they made.
Three different things called a solar meter
| Meter | Where it is | What it shows | Unit |
|---|---|---|---|
| Net meter, bidirectional or import export meter | At the grid connection, owned by the utility | Energy bought from the grid and energy sent back | kWh, separate registers |
| Generation meter | Between the inverter and your consumer unit | Total energy produced by the panels | kWh, one rising total |
| Inverter display or app | On the inverter or your phone | Live power, today’s energy, lifetime energy | W or kW, and kWh |
| Handheld irradiance meter | In your hand, pointed at the sky | Sunlight power falling on a surface | W/m2 |
The first three measure electricity. The fourth measures light. Mixing them up is the most common reason a reading looks impossible.
Reading a net meter’s import and export registers
Most modern electronic meters show one value at a time and cycle through a sequence, either automatically every few seconds or when you press a button. Each value has a short label or code beside it. On many meters that follow the common international coding, a code like 1.8.0 marks total imported energy and 2.8.0 marks total exported energy; other meters label them simply as import and export, or with arrows pointing toward and away from the grid. Your utility’s meter guide lists the codes for your model.
- Stand in front of the meter and watch the full cycle of displays once without writing anything.
- Identify the import and export registers by their codes or arrows. Ignore registers for voltage, current, maximum demand or time unless you need them.
- Write down both kWh totals, with the date. Photographs work well.
- Repeat on the same date next month.
- Subtract: this month’s import minus last month’s import is what you bought; this month’s export minus last month’s export is what you sent back.
Example: import rose from 12,410 to 12,655 kWh, so you bought 245 kWh. Export rose from 3,120 to 3,388 kWh, so you exported 268 kWh. If your tariff nets the two, your billed energy is close to zero; if it pays a different rate for export, the two are priced separately. Check your bill shows matching numbers.
If the meter has a pulsing light, it usually flashes faster as more power flows. Some meters show a direction indicator that flips when you begin exporting on a sunny afternoon with few loads running.
Checking whether generation looks right
The generation meter or inverter lifetime total tells you production. To judge whether it is reasonable, estimate what the system should make:
Expected daily kWh = system size in kW x peak sun hours x performance factor
Peak sun hours are the daily solar energy at your location expressed as hours of full sun at 1,000 W/m2; they vary with season and climate. The performance factor of roughly 0.75 to 0.85 covers heat, wiring, inverter losses and dirt. For a 4 kW system on a day with 5 peak sun hours: 4 x 5 x 0.8 = 16 kWh. A reading of 14 to 17 kWh is normal; 8 kWh on a clear day is worth investigating.
Compare like with like. A cloudy week, winter sun angles, or a tree that leafed out in spring can all lower output without any fault. The article on why solar output changes during the day explains the normal curve, peaking around solar noon.
The inverter app and the generation meter rarely match exactly. The app may round values, reset its daily total at a different hour, or measure on the DC side before inverter losses, while the meter measures the AC energy actually delivered. A difference of a few percent is normal. If the two disagree by a large and growing amount, trust the sealed meter for billing purposes and ask the installer to check the inverter’s monitoring setup.
Reading a handheld irradiance meter
A handheld meter such as the Triplett SPLT400 irradiance meter shows how much solar power reaches its sensor, in watts per square metre. Background is in what solar irradiance is.
- Hold the sensor flat against the panel surface or parallel to it, so it sees the sun at the same angle as the panel. Holding it flat on the ground gives a different number for a tilted array.
- Keep your shadow and hand off the sensor. Wait a few seconds for the value to settle.
- Bright clear midday sun on a well angled panel is often in the region of 800 to 1,000 W/m2; thin cloud can halve that, and heavy overcast can drop it far lower.
Use the irradiance reading to sanity check panel output. If irradiance is 800 W/m2, a panel rated 400 W at standard test conditions might deliver very roughly 0.8 x 400 = 320 W before temperature and wiring losses, and usually less on a hot day. A big shortfall against that estimate points to shading, soiling, a failed string or an inverter fault. The method is set out in how to measure solar panel output and irradiance versus panel output.
When the numbers point to a fault
- Export register not rising on sunny days: the inverter may be off or tripped, or your home is using all the power. Check the inverter status first.
- Generation meter stuck: look for an inverter error code or a tripped AC isolator. If the inverter shows production but the meter does not move, the meter may be faulty.
- Import reading higher than expected after installation: the meter may not have been replaced or reprogrammed for export. Contact the utility.
- Output well below the irradiance estimate: clean the panels if safe from the ground, check for new shading, then call the installer.
Never open the meter box or the inverter. Utility meters are sealed, and panels produce DC voltage whenever light falls on them, even with the grid switched off. Resetting a tripped isolator on the inverter is fine if the manual allows it; anything inside the enclosure is a job for the installer or a licensed electrician.
Take two photos today
Photograph the import and export registers on your meter and the lifetime total on the inverter today, then again on the same date next month; subtract, compare generation with size times peak sun hours times 0.8, and contact the installer if a clear-weather month falls well short.
Frequently Asked Questions
Which reading on my net meter is the export?
Look for a register labelled export, an arrow pointing away from the house, or a code such as 2.8.0 on meters using the common international coding. Your utility's meter guide confirms the labels for your model. Watch the full display cycle once before writing anything down.
Why does my export reading not match what the inverter generated?
Export is only what your home did not use at the moment it was generated. Generation minus self-consumption equals export, so the export figure is always lower than generation unless the house used nothing.
What is a normal reading on a solar irradiance meter?
Bright midday sun on a surface facing it often reads in the high hundreds up to around 1,000 W/m2. Morning, evening, cloud and haze all lower it. The figure measures light, not electrical output.
Can I use an irradiance meter to check if my panels are faulty?
It helps as one input. Measure irradiance in the plane of the panels, estimate expected power from the panel rating, and compare with the inverter's live reading. A large gap suggests a problem worth investigating with the installer.
How often should I record my solar meter readings?
Monthly is enough for billing checks and spotting slow decline. If you suspect a fault, daily readings for a week of clear weather give a much clearer picture.