Skip to content
AkerminMeasure. Monitor. Improve. Compare Products
Learning Center

Does a Voltmeter Have High or Low Resistance?

You have read that voltmeters have high resistance and ammeters low, and you want to understand why, or you suspect your meter is giving a wrong reading on a sensitive circuit. Both come down to the same idea, called loading.

As an Amazon Associate, Akermin earns from qualifying purchases. Product links on this page are affiliate links.

High, and the higher the better. A voltmeter is connected in parallel across the part being measured, so any current it draws is current stolen from the circuit; a very high resistance keeps that current tiny and the reading true. Most digital multimeters present about 10 megohms on their voltage ranges, while older analog meters have much less, often quoted as a figure in ohms per volt. The exception is deliberate: some meters offer a low-impedance mode that drops the input resistance on purpose so that induced ghost voltages collapse and only a real supply shows up.

Why an ideal voltmeter has infinite resistance

A voltmeter measures the potential difference between two points by sitting in parallel with whatever is between them. In parallel, the circuit current splits between the component and the meter. An ideal voltmeter takes none of that current, which is the same as saying it has infinite resistance. Then the circuit behaves exactly as it would with no meter at all, and the reading is the true voltage.

A real meter cannot be infinite. Inside a digital multimeter, the input on the voltage ranges is a precision divider chain, commonly totalling around 10 megohms, followed by a high-impedance converter. That draws about 0.1 microamps per volt measured: on a 12 V battery, roughly 1.2 microamps. For most circuits that is so small it changes nothing you could see.

An ammeter is the mirror image. It goes in series, so all the current flows through it, and an ideal ammeter has zero resistance so it drops no voltage. Getting these two backwards is the classic beginner mistake, and the consequences are not symmetrical, as the table below shows.

Typical input resistance by meter type

Instrument or mode Typical input resistance What it means in practice
Digital multimeter, normal V range About 10 megohms Negligible loading in household and most electronic circuits
Bench meter, high-impedance setting on low ranges Can exceed 10 gigohms on some models For very high impedance sources such as sensors and references
Analog meter, 20,000 ohms per volt, 10 V range About 200 kilohms Loads medium-impedance circuits noticeably
Analog meter, 1,000 ohms per volt, 10 V range About 10 kilohms Significant loading on almost anything but a stiff supply
Low-impedance (LoZ) mode Kilohms range, much lower by design Kills ghost voltage; not for sensitive electronics
Ammeter or current range Fractions of an ohm on amp ranges, higher on microamp ranges Never place across a voltage source

The analog “ohms per volt” figure works like this: multiply it by the full-scale voltage of the range you are on. The same meter has more input resistance on higher ranges, which is why old servicing manuals specify which meter sensitivity their test voltages were taken with.

Worked example: when loading spoils a reading

Take a 10 V supply feeding two 1 megohm resistors in series. The midpoint should sit at 5 V.

  1. Digital meter, 10 megohms. Placing it across the lower resistor puts 1 megohm and 10 megohms in parallel: (1 x 10) / (1 + 10) = about 0.909 megohms. The divider is now 1 megohm over 0.909 megohms, so the midpoint reads 10 x 0.909 / 1.909, about 4.76 V. That is roughly 5 percent low.
  2. Analog meter, 200 kilohms. Now 1 megohm in parallel with 0.2 megohms is about 0.167 megohms. The midpoint reads 10 x 0.167 / 1.167, about 1.43 V. That reading is wildly wrong.
  3. Same circuit with 1 kilohm resistors. With the digital meter, 1 kilohm in parallel with 10 megohms is still 0.9999 kilohms. The reading is 5.00 V to the precision of any handheld meter.

The rule of thumb: if the meter’s input resistance is at least a hundred times the resistance of the circuit at the measuring point, loading error is around one percent or less. Below that ratio, expect the reading to be low.

Checking whether your meter is loading the circuit

  • Look up the input impedance in the manual for the range you are using. It is usually listed in the specifications as input impedance on DC and AC volts.
  • Compare two ranges or two meters. On an analog meter, if the reading changes noticeably when you switch to a higher range, loading is affecting it. On digital meters, try a second meter; if both agree, loading is unlikely.
  • Estimate the source resistance. If the point you are measuring is fed through megohm-scale resistors, a sensor output or a high-value pull-up, expect some loading.
  • Measure a known divider. Two equal low-value resistors across a fresh battery should split the voltage evenly; this confirms the meter itself reads correctly.

For stable, sensible readings, a general-purpose digital multimeter such as the Fluke 117 or the VEVOR 6000-count multimeter is more than adequate. The page on choosing a digital multimeter explains which specifications to read.

If loading cannot be avoided, you can correct for it. Knowing the source resistance at the test point and the meter’s input resistance, the true voltage equals the reading multiplied by (source resistance plus meter resistance) divided by meter resistance. In the first example above, the source resistance seen at the midpoint is the two 1 megohm resistors in parallel, 0.5 megohms, so the correction is 4.76 x (0.5 + 10) / 10, which returns 5.0 V. It is a handy check when only one meter is available.

When you want low resistance on purpose

The same high input resistance that makes a digital meter accurate also makes it sensitive to voltage that is not really there. A disconnected wire running beside a live one picks up a few tens of volts through capacitance. A 10 megohm meter reads that happily; the guide on ghost voltage on a multimeter covers it in detail.

Low-impedance modes solve this by placing a much smaller resistance across the probes. The coupled source cannot supply enough current through it, so its voltage collapses toward zero, while a genuine mains supply barely notices the extra load. Electricians use this to decide whether a wire is truly live.

Do not use a low-impedance mode on electronics, sensor outputs or control circuits; it draws enough current to disturb them and in some cases trip a GFCI or RCD. And whatever the impedance, any meter used on mains must carry a suitable CAT rating and be used with undamaged leads. For safety-critical decisions such as whether a circuit is dead, follow a prove, test, prove routine, and use a licensed electrician for fixed wiring work you are not trained to do.

Find the figure for your own meter

Open your meter’s manual, find the input impedance listed for DC volts, and compare it with the resistance of the circuit you are measuring. If it is at least a hundred times higher, trust the reading; if not, use a higher-impedance meter or allow for the loading with the parallel-resistance arithmetic above.

Frequently Asked Questions

Why should a voltmeter have high resistance?

Because it sits in parallel with the part being measured. Any current it draws changes the circuit and lowers the voltage it is trying to read. High resistance keeps that current, and the error, negligible.

What is the input resistance of a typical multimeter?

Most digital multimeters present around 10 megohms on their voltage ranges. Some bench meters offer much higher impedance on low ranges, and analog meters are usually lower, depending on their ohms per volt rating.

Why does an ammeter have low resistance?

It is connected in series, so all the circuit current passes through it. Low resistance means it drops very little voltage and does not change the current it is measuring.

Can a voltmeter's resistance cause wrong readings?

Yes, on high-impedance circuits. When the meter's resistance is not much larger than the circuit's at the measuring point, it pulls the voltage down and reads low. Analog meters suffer from this far more than digital ones.

What is LoZ on a multimeter?

A low-impedance voltage mode that deliberately loads the circuit so that induced ghost voltage collapses. It helps confirm whether a wire is really live, but it should not be used on sensitive electronics.