Panels themselves rarely fail all at once, so a system showing zero almost always has a problem downstream: the inverter has shut down or faulted, a breaker or AC disconnect has tripped, the grid is down and the inverter has switched off for safety, or only the monitoring has lost its internet connection. Start at the inverter display and the breaker panel, then confirm there is real sunlight on the array. Leave the roof wiring and the DC connectors to a qualified installer, because panels generate dangerous DC voltage whenever light hits them.
Where the power actually stops
A grid-tied system is a chain. Light hits the cells and produces DC current; the DC travels through connectors and sometimes optimizers to an inverter, which converts it to AC; the AC passes through a breaker and often a separate disconnect switch into your home and the grid; a monitoring device reports what the inverter sees. A break anywhere in that chain makes the app read zero, even though the panels are still generating voltage on the roof.
Two features catch people out. First, a grid-tied inverter is required to stop exporting when the grid goes down, so that it does not energise lines that utility workers believe are dead. Unless you have a battery system designed to island, a power cut means no solar, even at noon. Second, monitoring is a separate path. If your router changed, the Wi-Fi password was updated or the monitoring gateway lost power, the app can show a flat line while the inverter keeps working normally.
Common causes, ranked by how often they happen
| Cause | How to spot it | What to do |
|---|---|---|
| Monitoring offline only | Inverter screen shows watts being produced, app shows zero or stale data | Reconnect the gateway to Wi-Fi, power-cycle the router and gateway |
| Tripped solar breaker or AC disconnect | Inverter dark or showing a grid or AC fault | Reset the breaker once; if it trips again, stop and call the installer |
| Grid outage or unstable grid | Neighbours also without power, or inverter reports grid voltage or frequency out of range | Wait; the inverter reconnects on its own after the grid is stable for a few minutes |
| Inverter fault or error code | Red light, fault message, fan noise with no output | Note the code, follow the restart sequence in the manual, then contact support |
| Shading, snow, heavy dirt | Output low rather than zero, worse at certain times of day | Clear snow from the ground with a soft roof rake, trim trees, rinse panels with plain water |
| Failed microinverter or optimizer | One panel shows zero in panel-level monitoring | Warranty claim through the installer |
| Loose connector, blown string fuse, damaged cable | A whole string missing, possibly after storm or pest damage | Professional repair only |
| Battery full or charge controller limiting (off-grid) | Output drops when batteries reach full charge | Normal behaviour; add loads or check controller settings |
Low output and zero output point to different things. Zero usually means something is switched off or faulted. A reduction of a third or a half, on a clear day, usually means shading, soiling, one failed string or a hot panel temperature reducing efficiency.
A safe step-by-step check from the ground
- Confirm the light. Early morning, late afternoon, thick overcast and winter sun all reduce output sharply. Compare with the same hour on a recent sunny day before assuming a fault.
- Read the inverter itself. Walk to the inverter and look at its display or status light. If it shows live watts, the panels are producing and the problem is monitoring. Photograph any error code.
- Check the breaker panel. Find the breaker labelled solar or PV. If it has tripped, switch it fully off and then on once. Check any external AC disconnect near the meter is in the on position.
- Check for a grid problem. If the whole house has lost power, the inverter is meant to be off. Wait for power to return.
- Restart in the right order. Most manuals describe a shutdown and startup sequence that covers the AC side and the DC isolator. Follow that exact sequence rather than flipping switches at random, and give the inverter several minutes to run its grid checks before it starts exporting.
- Look at the array from the ground. Snow, leaves, bird droppings, a new shadow from a growing tree or a neighbour’s extension are all visible without climbing.
- Check panel-level data. With microinverters or optimizers, the app often shows each panel. A single dark panel points to a failed unit rather than a system fault.
Do not open junction boxes, unplug MC4 connectors or touch roof wiring. Panels cannot be switched off while light falls on them, and DC arcs from a disconnected string can start fires.
Checking whether the output is actually wrong
Many people think production is broken when it is just a weak-light day. The fair test is to compare what you get with what the sunlight available should give. Panel ratings are measured at 1,000 W/m2 of light with the cells at 25 degrees C, conditions that rarely occur on a real roof. An explanation of solar irradiance shows why the same panel can give very different watts across one day.
A worked example: an array of ten 400 W panels has a 4,000 W rating. With a handheld meter such as a solar irradiance meter held at the same tilt as the panels, you read 650 W/m2. The ideal output is 4,000 x 650 / 1,000 = 2,600 W. Hot cells lose roughly a few tenths of a percent per degree above 25 C, and wiring and inverter losses take several percent more, so a reading somewhere around 2,100 to 2,300 W at the inverter is healthy. A reading of 1,300 W suggests about half the array is missing, which points to a dead string or failed inverter channel.
For small portable panels or a shed system that you own and can disconnect safely, a portable solar panel tester can read open-circuit voltage and short-circuit current directly. The guide to measuring solar panel output walks through that, and the difference between open-circuit and operating voltage explains why a panel can show normal voltage yet deliver little power. If a string shows the expected voltage but no current at the inverter, the fault is usually a connector, fuse or the inverter input.
When the fault is real and who should fix it
Call the installer or a licensed solar electrician when any of these apply:
- The solar breaker trips again after one reset.
- The inverter shows a ground fault, isolation fault or arc fault message. These indicate damaged insulation or wiring somewhere in the DC circuit and can be a fire risk.
- You see scorch marks, melted connectors, a burning smell or crackling sounds near the inverter or array.
- Output stays well below expected on clear days after the panels are clean and unshaded.
- One or more panels show zero in panel-level monitoring.
Rooftop DC strings on home systems commonly run at several hundred volts, which is far above safe touch levels, and the voltage is present whenever there is daylight. Testing those strings, especially isolation testing, needs the right category-rated equipment and training. If your system is under warranty, your installer may also need to document the fault themselves for a panel or inverter claim, so avoid opening anything that carries a warranty seal. Professionals use clamp meters rated for DC solar work; the notes on choosing a clamp meter for PV systems show what that kind of meter needs to handle.
Your first move today
Go and read the inverter display while the sun is up. If it shows watts being produced, your problem is the monitoring link and a router or gateway restart will usually fix it; if it is dark or showing a code, check the solar breaker once, write down the code, and send it to your installer with a note of when production stopped.
Frequently Asked Questions
Do solar panels work during a power cut?
A standard grid-tied system shuts down during a grid outage so it cannot feed power into lines being repaired. Only systems with a battery and equipment designed to island, or with a dedicated backup outlet feature, keep supplying power when the grid is down.
Can I reset my solar inverter myself?
Yes, a restart that follows the shutdown and startup sequence in the manual is a normal owner task. Use only the external breakers and isolators the manual tells you to use, and do not open the inverter case or disconnect DC cables.
How much does dirt reduce solar output?
Light dust has a small effect and rain usually clears it. Heavy dirt, pollen, bird droppings or lichen can cut output noticeably, especially on low-tilt panels, and a single patch of shading on one cell can drag down a whole string on systems without optimizers.
Why is my solar production lower in summer than in spring?
Panels lose efficiency as they heat up, so very hot summer days can produce less per hour than cool, bright spring days, even with more sunshine. Longer summer days usually still give a higher daily total.
Is it safe to hose down my solar panels?
Rinsing from the ground with plain water and a soft brush on an extension pole is generally fine; avoid pressure washers, harsh chemicals and cold water on very hot glass. Never climb onto the roof or stand on panels to clean them.