As an Amazon Associate, Akermin earns from qualifying purchases. Product links on this page are affiliate links.
It depends on what you mean by obey. At any one temperature, the voltage across a thermistor equals the current through it times its resistance at that moment, so V = IR holds. But a thermistor’s resistance changes strongly with temperature, and the current flowing through it heats it, so as you increase the voltage its resistance changes and the voltage-current graph curves away from a straight line. In the strict textbook sense, a component that obeys Ohm’s law has a constant resistance, so a thermistor is classed as non-ohmic.
What Ohm’s law really requires
Ohm’s law is often written as V = IR, but that equation by itself just defines resistance: the ratio of voltage to current at a given moment. Every component has a value of V divided by I. What makes a component ohmic is that this ratio stays constant as you change the voltage, provided physical conditions such as temperature stay the same. Plot voltage against current for an ohmic component and you get a straight line through the origin.
A thermistor is a resistor deliberately made to have a resistance that depends strongly on temperature. NTC (negative temperature coefficient) thermistors, the type used in most temperature probes, drop in resistance as they warm. PTC thermistors rise in resistance, often sharply above a switching temperature, and are used as resettable fuses and heater limiters.
So the honest answer has two parts. Hold the thermistor at a fixed temperature, and over a small range of current it behaves like an ordinary resistor: double the voltage, double the current. Let it warm up, from the room or from its own current, and its resistance moves, so the simple proportional relationship breaks.
Self-heating: why the graph curves
Any current through a resistance dissipates power as heat, P = I squared times R. A thermistor is small, so even a modest current raises its temperature above the surroundings. Manufacturers quote a dissipation constant, in milliwatts per degree, that tells you how much power raises the thermistor one degree above ambient in a given setting, such as still air or stirred liquid.
For an NTC thermistor the chain goes like this:
- You raise the voltage, so current rises.
- More current means more power dissipated, so the thermistor warms.
- Warmer means lower resistance.
- Lower resistance lets even more current flow than a straight line would predict.
At low voltages the heating is negligible and the graph is nearly straight. As voltage increases, the current climbs faster than proportionally, and with a large enough voltage the curve can even reach a point where the voltage across the thermistor stops rising, or falls, as current increases. That region is called negative resistance behaviour in the V-I curve, and it is why a thermistor run directly from a stiff voltage source with no series resistor can heat itself into trouble.
| Component | V-I graph at constant ambient | Ohmic? |
|---|---|---|
| Fixed metal film resistor | Straight line | Yes, within its rating |
| NTC thermistor, very low current | Almost straight | Approximately |
| NTC thermistor, higher current | Curves upward in current, can fold back | No |
| PTC thermistor near its switching point | Current limited sharply | No |
| Filament lamp | Curves the other way as resistance rises | No |
A worked example with real numbers
Take a common 10 kilohm NTC thermistor, meaning 10,000 ohms at 25 °C, with a B constant of around 3,950 kelvin, a typical value. Its resistance at another temperature can be estimated from the B equation: R = R25 times e to the power of B times (1/T minus 1/298.15), with T in kelvin.
At 25 °C, R is 10,000 ohms. Put 1 volt across it and the current is 1 divided by 10,000, or 0.1 milliamps. Power is 1 volt times 0.0001 amps, 0.1 milliwatts. With a dissipation constant of, say, 1 to 2 milliwatts per degree in still air, that warms the thermistor by about a tenth of a degree or less. Resistance barely changes, and V = IR with a constant R describes it well.
At 10 volts, if R stayed at 10,000 ohms, current would be 1 milliamp and power 10 milliwatts. That is enough to heat the thermistor several degrees above ambient in still air. Suppose it rises to about 30 °C. Using the B equation, resistance at 303.15 K is about 10,000 times e to the power of 3,950 times (1/303.15 minus 1/298.15), which is about 10,000 times e to the power of minus 0.219, roughly 8,000 ohms. The current is then about 10 divided by 8,000, or 1.25 milliamps, not 1 milliamp. That extra current adds more heat, so the real figure settles a little higher still.
At every moment, V divided by I equals the thermistor’s resistance at its current temperature. But the resistance at 10 volts is not the resistance at 1 volt, which is exactly why the graph is not straight.
Why it matters for temperature measurement
Self-heating is the main way a thermistor probe misleads you. The probe reports its own temperature, and if the measuring current warms it, the reading is higher than the air or liquid around it. Instrument makers avoid this by using a very small excitation current, often in the microamp range, or by pulsing the current briefly when taking a reading.
- Still air is worst. Heat leaves slowly, so self-heating error is largest. A probe in a freezer or a room shows this more than one in stirred water.
- Small probes heat faster. Tiny bead thermistors respond quickly but have lower dissipation constants.
- Readings take time. A thermistor needs time to reach the temperature of its surroundings; why temperature sensors need time to stabilise covers this.
With a ready-made dual-probe logger such as the Elitech GSP-6, the measuring current is set by the instrument, not by you. If you are building your own circuit, keep the measuring current low, use a voltage divider with a series resistor near the thermistor’s resistance in the range you care about, and convert with the B equation or the more accurate Steinhart-Hart equation. For comparing sensor types, see thermocouples and thermistors compared.
Measuring a thermistor with a multimeter
A multimeter on its ohms range passes a small test current through the thermistor and reports V divided by I. Because the test current is small, it gives a good reading of the resistance at the current temperature. To check a thermistor:
- Let it sit at room temperature for several minutes, away from your hands.
- Measure resistance. A 10 kilohm NTC at about 25 °C should read close to 10,000 ohms, within its tolerance.
- Hold it between your fingers. An NTC reading should fall steadily as it warms; a PTC should rise.
- For a precise check, place it in a well-stirred ice and water bath. A 10 kilohm thermistor with a B value around 3,950 reads roughly 32,000 to 34,000 ohms at 0 °C; check the manufacturer’s table for your exact part.
An open circuit or a reading that does not change with temperature means the thermistor is damaged. Do not test thermistors that are part of mains-powered equipment while it is connected; switch off and unplug first.
Test it yourself
Measure a thermistor’s resistance at room temperature with a multimeter, then hold it in your fingers and watch the number change; that changing value is the reason a thermistor is called non-ohmic, even though V divided by I always gives its resistance at that moment.
Frequently Asked Questions
Is a thermistor an ohmic or non-ohmic conductor?
It is classed as non-ohmic, because its resistance changes with temperature and its current heats it, so its V-I graph is not a straight line. At a fixed temperature and low current it behaves nearly ohmically.
Why does an NTC thermistor's resistance fall when hot?
It is made from semiconducting metal oxides. Heating frees more charge carriers, so more current can flow for the same voltage, lowering resistance.
Does a filament lamp obey Ohm's law?
Also no, in the strict sense. Its tungsten filament's resistance rises as it heats, so its V-I graph curves the opposite way to an NTC thermistor.
What is the Steinhart-Hart equation?
It is a three-coefficient equation relating a thermistor's resistance to temperature more accurately than the simpler B equation, across a wider range.
Can I use a thermistor as a resistor in a circuit?
Only where its temperature dependence is wanted, such as for sensing, inrush current limiting or compensation. Where a stable resistance matters, use a fixed resistor.