Skip to content
AkerminMeasure. Monitor. Improve. Compare Products
Review

UNI-T UT196 Review: 1700 V of Measuring Range Inside a 1000 V Category

The two headline voltages on this listing are not describing the same thing, and the difference decides where the meter may be used. It will display 1700 V DC. Its safety category stops at 1000 V. Then there is a 3000 A figure in the product name that no bullet supports, on a meter whose bullets never mention a current function at all.

As an Amazon Associate, Akermin earns from qualifying purchases. Product links on this page are affiliate links.

UNI-T UT196 Review: 1700 V of Measuring Range Inside a 1000 V Category

UNI-T · UNI-T UT196 True RMS Solar Digital multimeter for Solar Power System Maintenance 1700V DC /1500V AC, 3000A IP65 2m Drop

View on Amazon

Price and availability are shown on Amazon and can change at any time.

A True RMS digital multimeter with a 6000 count dual display, a stated measuring range of 1700 V DC and 1500 V AC, a safety rating of CAT III 1000 V and CAT IV 600 V, IP65 sealing, a 2 m drop claim, a low pass filter, a low impedance mode, non contact voltage detection, a flashlight, automatic ranging, resistance, frequency and capacitance. Read the two big voltages carefully, because they answer different questions. The display will show 1700 V. The certified category stops at 1000 V, and on a solar array that is the figure that governs where the probes may go.

Seventeen hundred volts of range inside a thousand volt category

The product name leads with 1700 V DC and 1500 V AC. The second bullet says CAT III 1000 V and CAT IV 600 V. Both are accurate, and they are describing two unrelated properties.

A measuring range is about the display. It says the largest value the instrument can represent before it gives up and shows an over range indication.

A category rating is about survival. Electrical systems carry brief, high energy voltage transients, and how much energy is behind one depends on where in the installation you are standing. The category number encodes that position, and the voltage attached to it is the working level the protection is certified for at that position. Both parts are needed to mean anything.

So the sentence this listing does not write is the useful one. This meter will display up to 1700 V DC. Its certified envelope is 1000 V in CAT III positions and 600 V in CAT IV positions. Those two statements coexist perfectly well in an engineering sense, because display headroom and input protection are built separately, and giving the display more range than the rating costs almost nothing.

Where it becomes a problem is in how a buyer reads a product name. This instrument is sold as a solar multimeter for photovoltaic system maintenance. Utility scale arrays run their direct current side high specifically to reduce losses, and a buyer who sees 1700 V in the title is likely to conclude that the meter is suited to the largest strings in common use. The category rating says it is not, and a cold bright morning pushes open circuit voltage higher still. Our explainer on why voltage readings can mislead deals with the related trap of trusting a displayed number without asking what produced it.

The honest position is this. Treat 1000 V CAT III as the operating limit of this instrument, not 1700 V, and judge whether that covers your work. For residential and light commercial arrays it generally will. For high voltage strings, our guide to meters rated for 1500 V photovoltaic work is the right list, and the qualifying figure there is the category rating rather than the display range.

Three thousand amps appears in the name, and nowhere else

There is a second number in the product name worth stopping on: 3000 A.

Now read the five bullets looking for it. True RMS, voltages, count, dual display. Category and ingress rating. Low pass filter and low impedance mode. Non contact voltage detection and a flashlight. Automatic ranging, resistance, frequency, capacitance.

There is no current function in that list at all. Not alternating, not direct, not microamps, not milliamps. No clamp is named, no flexible probe is named, and the input jacks of a handheld multimeter could not carry a fraction of three thousand amperes in any case.

So the number is unsupported by anything on the page. It may belong to a compatible clamp accessory, and the bullets do not say so. What can be said without inventing anything is that the figure has no explanation in the listing, and that is the sort of orphan specification to settle in writing rather than assume.

A solar meter whose bullets never mention current

The absence above is worth its own section, because of what the instrument is sold for.

Photovoltaic maintenance rests on two measurements. Open circuit voltage tells you a string is intact and producing. Short circuit or operating current tells you how much it is actually delivering, and comparing current between parallel strings is how a weak or shaded string is found. Voltage alone will not identify a string that is producing half the current of its neighbours, because voltage is largely set by the cells in series and barely moves with irradiance.

A meter marketed for solar power system maintenance that publishes no current function in its bullets is therefore describing half the job. Our note on low impedance multimeters covers the voltage side of the work this instrument is genuinely good at, and the current side needs either a clamp or a clear statement from the seller about what the orphan figure in the title refers to.

Nothing here is a reason to dismiss the instrument. It is a reason to know what else you will be carrying.

Low impedance mode and the low pass filter earn their place

The third bullet is the one that shows someone thought about the work, and it contains two functions that solve two of the most frustrating problems in electrical testing.

Low impedance mode addresses a reading that is real and means nothing. A multimeter normally presents a very high input impedance, deliberately, so that connecting it does not change the circuit. The side effect is that it will happily display a voltage induced onto an idle conductor by capacitive coupling from live cables running alongside it. There is no source behind that voltage, no current available, and no fault, but the display shows volts and people spend an afternoon looking for a problem that is an artefact of their instrument. Switching to a low impedance mode puts a load across the input, which collapses a coupled voltage immediately and leaves a genuinely connected one almost unchanged. One reading, one answer.

The low pass filter addresses the opposite failure. On the output of an inverter or a variable speed drive, the waveform is not a sine wave but a rapid train of switched pulses. A wideband True RMS meter includes all that high frequency content in its calculation and reports a voltage higher than the motor responds to. The filter removes the carrier so the display reflects the fundamental. Without it, an inverter output measurement is a number nobody can act on.

Both features are specific to the two environments this meter is aimed at, which are photovoltaic systems and electronically driven equipment. Neither appears on a basic meter, and their presence tells you more about the design intent than the voltage in the name does.

IP65, a two metre drop, and the rest of the page

Specification Published in the listing
Measurement type True root mean square
Measuring range 1700 V DC, 1500 V AC
Safety rating CAT III 1000 V, CAT IV 600 V
Display 6000 count, dual display
Ingress protection IP65
Drop claim 2 m, stated in the product name
Signal handling Low pass filter, low impedance mode
Other functions Non contact voltage detection, flashlight, automatic ranging, resistance, frequency, capacitance
Current measurement, any kind Not stated in the listing bullets
What the 3000 A figure refers to Not stated in the listing bullets
Accuracy, any function Not stated in the listing bullets
Resistance, frequency and capacitance ranges Not stated in the listing bullets
Continuity and diode test Not stated in the listing bullets
Temperature measurement Not stated in the listing bullets
Battery type and life Not stated in the listing bullets
Display backlight Not stated in the listing bullets

IP65 and the drop claim are the kind of specifications that only matter once the instrument is out of the box, and they are both real figures rather than adjectives. The 6 means dust tight, which is a stronger claim than the dust protected level below it, and the 5 means protected against water jets from any direction. That combination suits a rooftop, a field array and a plant room, and it is better sealing than most handheld meters publish.

A 2 m drop figure is the other half of field survivability, and it is the realistic failure mode: not immersion, not dust, but a meter going off a roof edge or out of a hand at head height.

The 6000 count figure is worth understanding rather than skipping, since it governs resolution. A count is the largest number the display can show, so on a 600 V range a 6000 count meter resolves in steps of 0.1 V, and on a 60 V range in steps of 0.01 V. More counts means finer steps, and 6000 is a mid range figure that suits general work without pretending to bench instrument resolution.

The dual display pairs with it usefully. Two values at once means, for example, watching a voltage while reading frequency, which is a single glance instead of a mode change.

The gap that matters most in the blank rows is accuracy. Not one tolerance figure appears for any function, which means every reading on this instrument arrives without a stated uncertainty. For deciding whether something is live, that does not matter. For recording an open circuit voltage against a datasheet, it does.

The buyer this fits, once the rating question is settled

This suits an electrician or a maintenance technician working on residential and light commercial photovoltaic systems and on inverter fed or variable speed equipment, who wants one rugged meter for both. The low impedance mode and the low pass filter are the right pair of features for that mix, the IP65 sealing and the drop claim fit outdoor work, the dual display and True RMS front end are appropriate, and 6000 counts is enough resolution for field decisions.

Two groups should pause. Anyone commissioning high voltage photovoltaic strings should read the category rating rather than the product name and conclude that this is not the instrument, because the certified envelope is 1000 V in CAT III positions and that is the number that governs the work. And anyone expecting to measure string current should establish what the 3000 A figure in the title refers to before ordering, because no bullet on the page describes a current function of any kind.

Settle those two questions and what remains is a well specified, well sealed field meter with two genuinely useful signal handling features and an honest dual safety rating printed where it can be read.

UNI-T UT196 True RMS Solar Digital multimeter for Solar Power System Maintenance 1700V DC /1500V AC, 3000A IP65 2m Drop

UNI-T UT196 True RMS Solar Digital multimeter for Solar Power

View on Amazon
ETCR6920B Flexible Rogowski Coil Clamp Multimeter 0-10000A Φ300mm | Measures AC current, AC/DC voltage, resistance & continuity. Φ300mm coil, USB logging, 600-record memory

ETCR6920B Flexible Rogowski Coil Clamp Multimeter 0-10000A Φ300mm | Measures

View on Amazon
Underground Wire Locator, Electrical Wire Tracer for Locate Buried Cable | Up to 1000ft Range, 3ft Deep, Rechargeable Wire Break Locator for Dog Fence & Irrigation Wires, with Flashlight & Headphone

Underground Wire Locator, Electrical Wire Tracer for Locate Buried Cable

View on Amazon
Klein Tools 80197 AC/DC Clamp Meter Kit with Magnetic Hanger Set | Auto-Ranging TRMS, 400 Amp, NCVT Set with Clamp Meter, Carrying Case, Test Leads, Thermocouple, Magnetic Hanger, Batteries

Klein Tools 80197 AC/DC Clamp Meter Kit with Magnetic Hanger

View on Amazon

Products shown because their documented specifications fit this guide. Price and availability are on Amazon and can change.

Frequently Asked Questions

Does 1700 V DC mean it can be used on a 1500 V array?

Those are two different questions and the listing answers only the easier one. 1700 V DC is a display range: the largest value the meter can represent. CAT III 1000 V is a safety rating: the position in an installation the input protection is designed for, and the working voltage at that position. The rating is the figure that governs where probes may be placed, and it stops well below the measuring range. Treat the higher number as headroom on the display, not as permission on the array.

Why would a meter have a range higher than its category rating?

It is a legitimate design rather than a mistake. The display range and the input protection are separate engineering problems, and giving the display more headroom than the certified working voltage costs little and avoids over range on an unexpected reading. The problem is one of presentation, not of design. When the large voltage appears in the product name and the category rating is in a bullet, buyers will read the first as a permission, and on this instrument it is not.

Is CAT IV 600 V better or worse than CAT III 1000 V?

Neither, they describe different places. The category number says how close to the incoming supply the instrument is built to be used, with CAT IV being nearest the service entrance where fault energy is highest, and CAT III covering fixed installation and distribution work. The voltage says the working level at that position. A dual rating of CAT III 1000 V and CAT IV 600 V means the meter is approved for higher working voltages further out in the installation and lower working voltages closer in, which is the normal shape of a dual rating.

What is the 3000 A figure in the product name?

Not explained anywhere in the bullets. No current function of any kind is listed, no clamp or flexible probe is named, and a handheld multimeter own input jacks could not carry anything approaching that figure. So what instrument or accessory the number belongs to is not stated. Settle it before buying, because for solar maintenance string current is one of the two measurements you most need.

What does low impedance mode do?

It deliberately loads the circuit while measuring. A normal multimeter has a very high input impedance so that it does not disturb what it is reading, and the side effect is that it will faithfully display a voltage that is only capacitively coupled from a nearby live conductor rather than connected to anything. That phantom reading sends people chasing faults that are not there. A low impedance mode presents enough load to collapse a capacitively coupled voltage while leaving a genuinely connected one standing, which turns an ambiguous reading into an answer.

What is the low pass filter for?

Stripping high frequency content out of a voltage measurement so the display reflects the fundamental the load actually responds to. The output of an inverter or a variable speed drive is not a sine wave, it is a rapidly switched waveform whose high frequency components a wideband meter will include in its reading. The result is a figure well above what the motor sees. Switching in a low pass filter removes the carrier and leaves the underlying waveform, which is why the function appears on meters intended for drives and inverter fed equipment.

Affiliate disclosure: Akermin earns a commission from qualifying Amazon purchases made through links on this page. Our editorial picks are based on documented specifications and owner feedback, not commissions.