Skip to content
AkerminMeasure. Monitor. Improve. Compare Products
Learning Center

Which thermal camera features change what you can actually see

Thermal camera listings mix two very different kinds of specification: the ones that decide whether a fault appears on screen at all, and the ones that decide how the picture looks afterwards. Separating them makes the upgrade decision much simpler, because the four cameras here disclose their native arrays very differently.

As an Amazon Associate, Akermin earns from qualifying purchases. Product links on this page are affiliate links.

Three specifications change what you can see: the number of real detector pixels, the thermal sensitivity figure in millikelvin, and whether you can set emissivity. Everything else on a thermal camera listing changes how the result looks or how conveniently it is stored. Upscaled or super resolution figures are the clearest example of the second group, because they multiply display pixels without adding a single new temperature measurement, and in this group of four cameras the native array behind the upscaled figure ranges from 320 by 240 down to 120 by 90.

Native detector pixels against upscaled resolution

A thermal camera measures temperature at a fixed grid of microbolometer elements. That grid is the whole of the camera’s information about the scene. A 320 by 240 array makes 76,800 measurements per frame, a 256 by 192 array makes 49,152, and a 120 by 90 array makes 10,800. Upscaling takes those measurements and fills in the gaps by interpolation. The result is a smoother image that prints better and hides the blocky edges, and it is genuinely easier to look at. It contains no new information.

What makes this hard to shop for is that the two numbers are often printed next to each other without labels. The FOXWELL RT280 is unusually clear about it: the bullets state that its enhancement technology takes the effective resolution from 120 by 90 up to 240 by 180, so the native array is disclosed outright. The Thermal Master Thor001 is equally explicit the other way round, stating that it upscales a native 256 by 192 to 512 by 384. Both are being honest. The difference between them is roughly a factor of four and a half in real measurements per frame.

The pillar page on thermal camera resolution works through why a 320 by 240 class detector is the usual dividing line for building and electrical work, and why the display panel resolution quoted in the same bullet is a separate thing again.

NETD decides whether a faint fault shows up at all

Noise equivalent temperature difference is the temperature difference that produces a signal equal to the detector’s own noise. Below it, a pattern is present in the data but buried. A camera quoted at fifty millikelvin cannot reliably render a pattern whose contrast is fifty millikelvin, because signal and noise are the same size. The same scene at a tenth of a degree of contrast is comfortable for a thirty five millikelvin instrument.

This is why sensitivity, not pixel count, is what separates jobs. Missing loft insulation, a blocked radiator, a leaking pipe under a floor and a hot terminal all present a degree or several of contrast, and almost any current camera finds them. A conductor at a quarter of its rating, a stud line behind plaster on a mild day, the airflow pattern across a vent, early stage water ingress that has not yet cooled much: these live in the tenths, and sensitivity decides whether you see them or walk past. The explanation of NETD covers how the figure is measured and why it is quoted at a specific scene temperature.

Emissivity control is the line between imaging and measuring

A surface radiates according to its temperature and its emissivity. Matte paint, brick, plaster, skin and oxidised metal all sit somewhere around 0.9 to 0.95, which is why the factory default on almost every camera is in that region and why building surveys mostly work out of the box. Polished metal is the problem. Bare copper, clean aluminium and stainless steel can emit less than a tenth as much, and most of what the camera sees reflected off them is the temperature of whatever is in front of them, including the operator.

A camera that cannot be told the emissivity of the surface is an imager, not a thermometer, on anything shiny. It will still show you which of two identical busbars is hotter, because the error is common to both, and that comparison is most of practical electrical work. It will not give you a number you can put in a report. Of the four cameras here, the Thor001 bullets state adjustable emissivity explicitly; for the other three, emissivity adjustment is not stated in the listing bullets, which does not prove the function is absent but does mean you are buying on hope. The procedure for setting emissivity also covers the electrical tape and matte paint trick for getting a usable reading off a reflective surface.

Field of view, spot size and standing distance

Every detector pixel looks at a small cone of the scene. Divide the horizontal field of view by the horizontal pixel count and you have the angle each one covers. For a spot temperature to be valid rather than an average of the target and its surroundings, the target should fill something like a three by three block of those pixels. That gives a concrete working rule for how close you have to get.

Native array with a 50 degree horizontal lens Angle per pixel One pixel at 1 m Three by three block at 1 m Three by three block at 3 m
320 by 240 0.16 degrees 2.7 mm About 8 mm About 25 mm
256 by 192 0.20 degrees 3.4 mm About 10 mm About 31 mm
120 by 90 0.42 degrees 7.3 mm About 22 mm About 66 mm

That is the real cost of a small array. It is not a blurry picture, it is a minimum target size at a given standing distance, and on a circuit board or a terminal block it rules the camera out. A macro lens attacks the same problem from the optical end by shrinking the angle each pixel covers, and the Thor001 bullets state a detachable macro lens intended for board level work. The MiLESEEY TR20 takes the other route, stating a native 320 by 240 infrared array with a fifty degree wide angle lens and a sensitivity below forty millikelvin, so the pixel footprint is small without needing extra optics. For single point work the thermal camera against infrared thermometer page covers the same distance to spot arithmetic in its simpler form.

Features that photograph well and change nothing

The remaining specifications are not worthless. They are just not what decides whether you find the fault.

  • Storage capacity. The RT280 bullets state 8 GB of internal storage for more than twenty thousand images, and the DCTOPT thermal camera states a 4 GB removable card holding over ten thousand. Both are far beyond a working day. Capacity is a convenience, not a capability.
  • Colour palettes. Nine palettes versus three changes how obvious a pattern looks to a human eye, which matters for a report, and changes the underlying data not at all.
  • Image fusion and edge overlay. Laying visible light outlines over the thermal image is genuinely useful for saying where in the panel the hot thing is. It adds no thermal information.
  • Screen size. A 3.5 inch panel is easier to work from than a 2.8 inch one. The MiLESEEY bullets quote a 2.8 inch display at 480 by 640, which is a panel specification and has nothing to do with the 320 by 240 detector feeding it.
  • Multiple measurement points. Nine simultaneous spots, or automatic hottest and coldest tracking, saves time on site. Every one of those spots is still subject to the three by three rule above.

One genuine warning sign sits in this group. The DCTOPT title states 240 by 180 super infrared resolution while its first bullet states 240 by 240 super resolution technology, and the native array is not stated in the listing bullets at all. Internal inconsistency in a specification sheet is itself information about how carefully the rest of the figures were prepared.

Which upgrades change what you can see

Work down in this order and stop when the jobs you actually do are covered. First, native detector pixels, because they set the minimum target size and no amount of processing recovers them. Second, thermal sensitivity, because it sets the faintest pattern that is visible at all. Third, emissivity control, if you need a number rather than a comparison. Fourth, optics, meaning a lens or macro attachment that matches your working distance. Only then the conveniences: screen, storage, palettes, reporting software.

Applied to this group, that ordering favours the disclosed native arrays over the larger upscaled figures, and it makes the Thor001’s stated emissivity adjustment and thirty five millikelvin sensitivity the two most consequential differences in the set. For a worked example of how a smaller detector behaves in practice on building and electrical targets, the Seek Thermal imaging camera page goes through the same trade offs on a single instrument.

Frequently Asked Questions

Does super resolution add real detail?

No. Upscaling interpolates new display pixels from the measurements the detector already made, so a 120 by 90 array presented at 240 by 180 still contains ten thousand eight hundred real measurements. The picture looks smoother and the smallest object you can measure has not changed at all.

What NETD figure do I actually need?

For structural work with half a degree of contrast or more, such as missing insulation or a damp patch, anything in the forty to fifty millikelvin region is sufficient. For faint patterns like a lightly loaded conductor or airflow across a surface, where contrast may be a tenth of a degree, sensitivity becomes the limiting specification.

Why does emissivity adjustment matter so much?

Radiated energy depends on the surface, not just its temperature. A bare copper busbar and a painted steel plate at the same temperature emit very differently, so a camera locked at a single emissivity value will read a shiny surface far too cold. Without an adjustment you can compare one spot against another on the same material, but you cannot trust an absolute figure.

Is 25 Hz worth having over a slower refresh?

Yes, and it is the reason scanning a wall or a panel feels usable rather than frustrating. A slow refresh smears while you pan and forces you to stop and wait at every position. All four cameras in this topic state 25 Hz, so in this particular group it is not a differentiator.

How close do I have to stand for a spot reading to be valid?

Close enough that the target fills roughly a three by three block of detector pixels, not display pixels. With a fifty degree lens over a 320 by 240 array that block is about eight millimetres at one metre; over a 120 by 90 array with the same lens it is about twenty two millimetres at one metre and three times that at three metres.

Does a laser pointer show where the camera is measuring?

No. It helps you find the spot you are looking at in a cluttered panel, but it is offset from the optical axis and it does not mark the boundary of the measured area. The on screen cursor or box is what defines the measurement.