Breaker Keeps Tripping Due to Overload: How to Fix It for Good

You know the circuit is overloaded, or you suspect it: the breaker trips when the heater and the kettle run together, or when the hair dryer goes on. Here is how to prove it with numbers and fix it without a bigger breaker.

As an Amazon Associate, Akermin earns from qualifying purchases. Product links on this page are affiliate links.

An overload trip means the appliances running on one circuit together draw more current than the breaker is rated for, and the breaker is protecting the wiring from overheating. Add up the wattage of everything that runs at the same time, divide by the supply voltage to get amps, and compare that with the breaker rating; a 15 A breaker at 120 V supports about 1,800 W, a 20 A breaker about 2,400 W. Confirm with a clamp meter, then move high-wattage appliances to different circuits or have an electrician add a dedicated circuit. Never fit a larger breaker to stop the tripping.

What an overload is, and what it is not

Each circuit in a home is a length of copper wire of a given size, protected by a breaker sized to that wire. The breaker’s job is to cut the power before the current heats the wire enough to damage its insulation. A 14 AWG copper branch circuit is typically protected at 15 A; 12 AWG at 20 A. When the combined draw of everything running on the circuit goes above the rating, the breaker’s thermal element heats and eventually trips. That is an overload.

An overload is different from a short circuit, where current takes an unintended path with very little resistance and the breaker trips instantly, and from a ground fault, where current leaks to ground and a GFCI device trips. Overload trips usually happen after a delay, often when a particular combination of appliances runs at once, and the circuit works again normally once the load is reduced.

If you are not sure it is an overload, try the test that defines one: switch off or unplug the highest-wattage items and reset the breaker. If it then holds through the same period that used to trip it, overload is the answer.

Doing the load arithmetic

The basic formula is amps equals watts divided by volts. Most appliances list watts, or amps, on a rating plate or label on the back or base. Use the table below as a rough guide only; your appliance label is the real figure.

Appliance Typical wattage range Amps at 120 V
Portable space heater, high setting About 1,500 W About 12.5 A
Hair dryer About 1,200 to 1,875 W About 10 to 15.6 A
Electric kettle About 1,200 to 1,500 W About 10 to 12.5 A
Microwave oven, input power About 1,000 to 1,500 W About 8 to 12.5 A
Toaster or toaster oven About 800 to 1,500 W About 7 to 12.5 A
Vacuum cleaner About 500 to 1,400 W About 4 to 12 A
Window air conditioner, small About 500 to 1,000 W running About 4 to 8 A, more at start
Laptop, TV, lamps Tens to a few hundred watts Under 2 A each

Worked example: a 15 A bedroom circuit has a 1,500 W heater, a 300 W TV and game console, and 100 W of lamps. Total 1,900 W. At 120 V, that is 1,900 divided by 120, about 15.8 A, just above the breaker rating, which will trip after a while. Drop the heater to its low setting, often around 750 W, and the total falls to about 1,150 W, or 9.6 A, which is comfortable.

For loads that run for three hours or more, such as heaters, the usual design practice is to keep the continuous load at or below 80 percent of the breaker rating: 12 A on a 15 A circuit, 16 A on a 20 A circuit. A single 1,500 W heater on a 15 A circuit already sits right at that limit.

Measuring the real load

Labels are maximum ratings, and real draw can differ, especially for appliances with thermostats or variable motors. A clamp meter measures what is actually flowing.

  1. Find every outlet on the tripping circuit. Turning the breaker off and checking which outlets die works, or use a plug-in finder; see circuit breaker finders.
  2. For each heavy appliance, plug it into a line splitter and clamp around the single-conductor loop. A True RMS meter such as the ZIBOO 393 True RMS clamp meter reads correctly with electronic and motor loads.
  3. Record each appliance’s current while running normally.
  4. Add the currents of everything that runs at the same time and compare with the breaker rating.
  5. If someone qualified can open the panel, a single clamp reading on the circuit’s hot conductor gives the total directly.

While you are at it, measure the outlet voltage with a multimeter, idle and under load. A large drop under load suggests a loose connection or a long, undersized run, which can make the circuit heat even at normal loads. The comparison of outlet testers and multimeters covers that check.

Fixing an overloaded circuit

  • Spread the heavy loads. Move the heater, kettle or hair dryer to an outlet on a different breaker. Kitchens usually have two or more countertop circuits; use them both.
  • Stop stacking. Do not run a heater and a kettle, or a microwave and a toaster, on the same circuit at the same time.
  • Use lower settings. Many heaters and hair dryers have a half-power setting that halves the current.
  • Avoid extension leads and power strips for heaters. They do not add capacity; they just concentrate load on one outlet, and many cords are not rated for continuous heater current.
  • Add a dedicated circuit. For a home office, workshop, window AC or permanent heater, a licensed electrician can run a new circuit from the panel, subject to panel capacity.
  • Look at efficiency. Replacing old incandescent lighting or a worn appliance can trim the load on a borderline circuit.

Never replace a 15 A breaker with a 20 A one on 14 AWG wire, or tape or hold a breaker in the on position. That removes the protection for the wiring in your walls, which is exactly the part you cannot see overheating.

When the trip is not really overload

If your sums and measurements show the load is well below the breaker rating and it still trips, something else is going on. Possibilities include a heating loose connection, a worn breaker, an AFCI or GFCI device detecting a fault, or a failing appliance with an internal short. A breaker that feels hot, buzzes, or trips faster each time needs a licensed electrician. So does a circuit with scorched outlets or a burning smell. If several circuits all trip regularly, the home may simply have too few circuits for modern use, and an electrician can assess whether the panel and service have room for more.

Your fix in one evening

Read the wattage labels of everything on the tripping circuit, add up what runs together and divide by 120 to get amps. If the total is over about 80 percent of the breaker rating, move the heater or the next biggest load to another circuit tonight, and book an electrician for a dedicated circuit if that load has to stay where it is.

Frequently Asked Questions

How many watts can a 15 amp circuit handle?

At 120 V, a 15 A breaker supports about 1,800 W. For loads running three hours or more, keeping to about 1,440 W, or 80 percent, is the usual practice.

Can I replace my 15 amp breaker with a 20 amp one?

Not unless the circuit is wired with wire rated for 20 A, typically 12 AWG copper, along its whole length. A bigger breaker on smaller wire lets the wire overheat before it trips.

Does a power strip increase how much I can plug in?

No. It adds sockets, not capacity. Everything on the strip still draws through one outlet and one breaker.

Why does the breaker trip only in winter?

Space heaters, electric blankets and longer lighting hours add load in winter. A single heater uses most of a 15 A circuit on its own.

Is it dangerous if my breaker trips from overload often?

The breaker is protecting you, but frequent overloads wear it and stress connections. Reduce the load or add a circuit rather than living with regular trips.