As an Amazon Associate, Akermin earns from qualifying purchases. Product links on this page are affiliate links.
A pyrometer does measure temperature, typically surface temperature at high heat and without touching the object. Most modern pyrometers are infrared thermometers: they read the thermal radiation a surface emits and convert it to degrees, which is why an infrared temperature gun such as the 50:1 infrared thermometer gun is technically a pyrometer. The term is also used for thermocouple gauges on kilns and engines. Either way, accuracy depends on setting the right emissivity or probe type and aiming at a spot the instrument can actually resolve.
Three instruments people call a pyrometer
The word comes from Greek roots meaning fire and measure, and historically it meant any instrument for temperatures too high for an ordinary glass thermometer. Today it covers a few different devices.
- Infrared or radiation pyrometers. These collect infrared energy from a surface through a lens and focus it on a detector. Handheld infrared thermometers, fixed industrial sensors and many high-temperature guns belong here.
- Ratio or two-color pyrometers. These compare radiation at two wavelengths. Because the ratio changes less with emissivity, dust or a partly blocked view, they are popular in steel, glass and furnace work.
- Thermocouple pyrometers. A kiln controller or a pottery kiln gauge often calls itself a pyrometer even though it reads a thermocouple inside the chamber. This is a contact measurement, not an optical one.
All three measure temperature. They differ in whether they touch the object, what they are sensitive to, and how they go wrong. The rest of this page focuses on infrared types, since that is what most people holding a pyrometer actually have. For thermocouple types, the same principles apply as for any thermocouple probe.
How an infrared pyrometer turns heat into a number
Every object above absolute zero emits infrared radiation, and the amount rises very steeply as it gets hotter. The pyrometer’s lens gathers radiation from a circular spot, the detector converts it to an electrical signal, and the electronics calculate what temperature would produce that much radiation.
The catch is that real surfaces do not emit as much as an ideal radiator would at the same temperature. The fraction they do emit is called emissivity, a number between 0 and 1. Painted surfaces, wood, rubber and most non-metals are high, often around 0.9 or above. Polished metals can be very low, and they also reflect radiation from their surroundings. If the instrument assumes an emissivity of 0.95 and you point it at shiny aluminium, it will read far too low. Our article on what emissivity is explains why this happens.
The other key number is the distance to spot ratio. A 50:1 instrument measures a spot about one fiftieth of the distance: at 100 cm away, the spot is about 2 cm across. A 12:1 instrument at the same distance measures a spot about 8 cm across. If the target is smaller than the spot, the reading averages in the background.
Why a pyrometer reading can be wrong
| Cause | What you see | Fix |
|---|---|---|
| Emissivity set wrong | Shiny metal reads much colder than it is | Adjust emissivity, or apply high-emissivity tape or paint to a test spot |
| Target smaller than the spot | Reading drifts toward background temperature | Move closer or use a higher distance to spot ratio |
| Reflections | Reading changes as you move around the object | Change angle, shade the target, use tape or paint |
| Steam, smoke or dust in the path | Unstable or low readings | Clear the line of sight; consider a ratio pyrometer |
| Measuring through glass | Reads the glass, not the object behind it | Measure directly; ordinary glass blocks the infrared band most units use |
| Instrument not at room temperature | Offset after moving from cold to warm areas | Let it acclimatize before use |
| Above the stated range | Error message or capped reading | Use an instrument rated for the temperature |
Remember too that an infrared pyrometer measures only the surface. The inside of a thick roast, a molten pour under a crust, or the core of a motor can be very different. For internal temperature, use a contact probe.
Ambient conditions affect the instrument as well as the target, so keep the lens clean and free of fingerprints, since a smudged lens scatters radiation and lowers the reading.
Getting a reliable reading, step by step
- Identify the surface. Is it painted, oxidized, ceramic, or bright metal? Look up a typical emissivity or use the tape method below.
- Set emissivity if your pyrometer allows it. Models like the ennoLogic eT650D let you adjust it; fixed-emissivity units suit non-metals best.
- Work out the spot size. Divide distance by the D:S ratio and make sure the target is at least twice that size for a clean reading.
- Aim square on to the surface where possible; steep angles increase reflection.
- Scan and use MAX if you are hunting for the hottest point on a bearing, a pipe or a griddle.
- Cross-check with contact on one spot. A thermocouple probe on the same surface shows whether your emissivity setting is right.
The tape method is simple: put a small piece of black electrical tape or high-emissivity paint on the surface, wait for it to reach the surface temperature, and measure it with emissivity set near 0.95. Then measure bare metal next to it and adjust emissivity until both read the same.
Checking accuracy and staying safe around heat
A practical home check is a well-stirred ice bath with plenty of crushed ice. Aim at the water surface, not the ice cubes or the glass, with emissivity around 0.95. The reading should be close to 0 degrees C, or 32 degrees F, within the instrument’s stated accuracy. Boiling water gives a second check near 100 degrees C at sea level, though steam can disturb the reading. For high temperatures, comparison against a calibrated thermocouple in a kiln or furnace is the usual method. Instruments supplied with a calibration certificate save you that step when records are required.
Pyrometers are often used around dangerous heat. Never rely on a surface reading to decide whether something is safe to touch, because emissivity errors can make a hot metal surface look cool. Remember that the laser dot is only an aiming aid, not the measured area, and should never be pointed at eyes. For electrical panels, an infrared reading is a screening tool; work inside energized equipment is for qualified electricians. If you are deciding between a spot pyrometer and a camera, our comparison of a thermal camera and an infrared thermometer explains what each is good at, and our guide on choosing an infrared thermometer covers range and D:S ratio.
Before your next measurement
Look at what you are measuring, set the emissivity to match or put a strip of black tape on it, step close enough that the spot fits inside the target, and confirm one reading with a contact probe so you know how far you can trust the rest.
Frequently Asked Questions
Is a pyrometer the same as an infrared thermometer?
An infrared thermometer is one type of pyrometer. The word pyrometer is broader and also covers ratio pyrometers and thermocouple-based kiln and engine gauges.
Can a pyrometer measure body temperature?
General purpose infrared pyrometers are not medical devices and are not designed or approved for body temperature. Use a thermometer made and approved for that purpose.
Why does my pyrometer read low on stainless steel?
Bright stainless steel has low emissivity and reflects its surroundings, so the instrument sees less radiation than it expects. Raise accuracy by adjusting emissivity or measuring a spot covered with high-emissivity tape.
What is a two-color pyrometer for?
It compares radiation at two wavelengths, which makes the reading less sensitive to emissivity changes, dust or partial blockage. It is common in metalworking and furnaces where those conditions are hard to avoid.
How far away can I use a pyrometer?
As far as the spot size allows. Divide the distance by the distance to spot ratio, and keep the target at least as large as that spot, ideally larger.