Skip to content
AkerminMeasure. Monitor. Improve. Compare Products
Learning Center

Can Oscilloscopes Be Analog or Digital?

You have seen both chunky CRT scopes and slim digital ones and want to know whether they do the same job. They do, but in very different ways, and the difference changes what each can show you.

As an Amazon Associate, Akermin earns from qualifying purchases. Product links on this page are affiliate links.

Oscilloscopes come in both kinds. An analog oscilloscope feeds the amplified input signal straight to the deflection plates of a cathode ray tube, so the glowing spot traces the waveform in real time with no sampling. A digital oscilloscope converts the signal into numbers with an analog to digital converter, stores them, and draws the waveform on an LCD, which lets it freeze, measure, save and analyse signals. Almost every new scope sold is digital, while analog scopes survive on the used market and in teaching labs.

Two ways of drawing the same waveform

Both types answer the same question: how does this voltage change with time? They differ in how the picture is made.

In an analog scope, the input passes through an attenuator and an amplifier and is applied, as a voltage, to a pair of vertical deflection plates inside a cathode ray tube. A separate sweep circuit generates a steadily rising ramp that pushes the electron beam across the screen from left to right, then snaps it back. The trigger circuit starts each sweep at the same point on the waveform, so successive sweeps land on top of one another and the phosphor glows in the shape of the signal. Nothing is stored; once the beam passes, the glow fades.

In a digital storage oscilloscope, usually shortened to DSO, the conditioned input goes to an analog to digital converter that measures the voltage many millions of times a second. Those samples are written into memory. A processor then decides what to draw, joins the dots, and sends the result to a flat-panel display. Because the waveform exists as data, the scope can hold a single event on screen indefinitely, calculate frequency and rise time, perform math such as an FFT, and export screenshots.

The main families compared

Beyond the basic split there are a few hybrids and variants worth knowing by name.

Type How it works Strengths Weak points
Analog CRT scope Signal deflects an electron beam directly No sampling, no aliasing, instant response, shows intensity of repeated signals naturally Cannot capture one-off events easily, no automatic measurements, heavy, ageing tubes
Analog storage scope Special CRT that holds a trace on the screen Can freeze slow or single events without digitising Rare, limited storage time, hard to repair
Digital storage scope (DSO) Samples and stores the signal, redraws it Single-shot capture, measurements, saving, small size Can alias if sampling is too slow; screen update rate may miss rare glitches
Digital phosphor or high-update DSO Digital scope that layers many captures with brightness grading Imitates the analog look, shows rare events and jitter Mostly in higher-end bench models
Mixed signal scope (MSO) DSO plus extra logic channels Shows analog waveforms and digital bus timing together More complex and more expensive class of instrument
Handheld and PC-based scopes Digital front end in a meter-sized box or a USB module Portable, often combined with a multimeter or generator Smaller screens, shorter record length

A combined handheld unit such as the FNIRSI 2C53P is a digital design that pairs a two channel oscilloscope with a multimeter and a signal generator in one case, which is typical of the newest portable class.

How to tell which kind you have

  1. Look at the screen. A deep box with a round-cornered glass tube and a glowing green or blue trace is a CRT, so the scope is analog or analog storage. A flat LCD with menus and on-screen text means digital, even if the front panel still has many knobs.
  2. Look for a sample rate on the front panel. Digital scopes are labelled with both bandwidth in MHz and sample rate in samples per second, such as MSa/s or GSa/s. Analog scopes list only bandwidth.
  3. Press stop or single. A digital scope freezes the last capture. An analog scope has no such button, and the trace disappears when the signal stops.
  4. Check for USB, a menu system or measurement readouts. These almost always mean a digital design. Some late analog scopes added readouts of the knob settings on the CRT, but they still draw the waveform with the beam.

What the difference means at the bench

For most current work, digital wins. Microcontroller circuits, switching power supplies, serial buses and automotive sensors all produce one-off or irregular events that you need to capture and study, and a DSO’s single-shot trigger is built for that. Automatic frequency, peak to peak and duty cycle readouts save time and reduce errors.

Analog scopes still have fans for good reasons. The display responds instantly when you turn a trimmer, which makes adjusting audio, video or RF circuits feel natural. There is no sampling, so there is no risk of aliasing, the false lower-frequency picture a DSO can show when its sample rate is too low for the signal. Brightness also shows how often the beam traces each path, so a rare glitch looks faint and frequent behaviour looks bright.

On a digital scope, avoid aliasing by keeping the sample rate several times higher than the highest frequency in the signal; many engineers aim for at least four to five samples per cycle at the bandwidth limit. If a waveform suddenly changes completely when you speed up the timebase, the slower view was aliased.

If you are still choosing a first instrument, oscilloscope vs digital multimeter explains when a scope is needed at all, and multimeter vs oscilloscope walks through jobs where a meter is enough.

Checking either type reads correctly

Both types have a calibration output on the front panel, usually a square wave of about 1 kHz at a stated amplitude. Connect a probe and check three things:

  • the square wave has flat tops and sharp corners, which confirms the probe compensation is right;
  • the height matches the stated amplitude on the correct volts per division setting, which checks the vertical gain;
  • one cycle spans the expected time, about 1 ms, which checks the timebase.

On an analog scope, make sure the variable gain and variable time knobs are in their calibrated detents first. A digital scope may also offer a self-calibration routine in its utility menu, which should be run after the instrument has warmed up.

Safety and repair notes for old analog scopes

A CRT scope contains high voltage, often in the kilovolt range at the tube, and capacitors in the supply can hold a charge after the power cord is unplugged. Do not open the case unless you know how to discharge the tube and supply safely. Old units can also have dried-out electrolytic capacitors and brittle mains wiring, so a used analog scope that smells hot or hums loudly should be inspected by someone experienced before regular use. Neither type of scope is designed for direct mains measurement with a standard probe and ground clip; the ground lead is tied to the mains earth through the power cord, so use a differential probe or an isolated, properly rated instrument for line voltages.

Decide by the signals you will measure

List the signals you expect to measure; if any are one-off events, digital buses or need saving and measuring, choose a digital storage scope, and keep an analog scope only if you already own one or mainly tune steady audio and RF circuits.

Frequently Asked Questions

Are analog oscilloscopes still made?

Very few manufacturers still build them, and they are a small niche. Most analog scopes in use today are older bench units bought second hand or kept in schools and repair shops.

Is a digital oscilloscope less accurate than an analog one?

Not in general. A well specified digital scope usually measures voltage and time more precisely than reading a CRT by eye, and it adds automatic measurements. Its main risk is aliasing or a slow update rate, which you avoid with adequate sample rate and settings.

What does DSO mean on an oscilloscope?

DSO stands for digital storage oscilloscope. It samples the input, stores the data in memory, and redraws the waveform, so it can freeze and analyse signals.

Can a digital oscilloscope show the same picture as an analog one?

Higher-end digital scopes with intensity grading or digital phosphor displays layer thousands of captures and brighten frequently traced paths, which closely imitates the analog look. Basic digital scopes show a single, uniform trace.

Which type should a beginner buy?

A digital scope suits almost every beginner, because it can freeze signals, measure them automatically and save results for later study. An inexpensive used analog scope can still teach the basics well if one is already available.