A do-it-yourself radon test is usually one of two small, plain objects: a charcoal canister, often a round tin or foil-sealed pouch a few inches across with a mesh or gauze face, or an alpha-track detector, a small plastic puck or capsule with a filtered opening. Both sit still in the lowest lived-in room and are posted to a laboratory afterwards. Professional testers leave an electronic continuous monitor, a box about the size of a hardback book or smaller with a display or status lights, and home electronic monitors look like a small smoke alarm or desk clock. None of them make noise or smell, and none emit radiation; they only record it.
The main types side by side
| Type | What it looks like | Typical test length | How you get the result |
|---|---|---|---|
| Activated charcoal canister | Round metal or plastic tin, a few inches across, with a mesh or gauze screen; sometimes a sealed foil pouch | A few days | Reseal and post to the lab promptly |
| Alpha-track detector | Small plastic puck, cylinder or capsule, often black or white, with a filter-covered hole or slots | Three months up to a year | Post to the lab after the period ends |
| Electret ion chamber | Small cylindrical canister with a removable cap over a charged disc, used mostly by professionals | Days to months, depending on the electret | Read with a special voltmeter by the tester |
| Professional continuous radon monitor | A rugged electronic box with a display or lights, sometimes with tilt and tamper sensors | Usually at least two days | Hourly report printed or downloaded by the tester |
| Consumer electronic monitor | Desk or wall unit with a screen showing radon level, often temperature and humidity too | Continuous, readings stabilise over days | Live on the display or an app |
Kits normally arrive with a data sheet asking for the start date, time and location, plus a return envelope. The data sheet is part of the test; a lab may reject a detector without it.
How each one works, briefly
Radon is a colourless, odourless radioactive gas that seeps from the ground into buildings. Our page on what radon is and why long-term monitoring matters explains where it comes from.
- Charcoal soaks up radon from the air over the exposure period. The lab counts the radiation from the trapped radon and calculates the average concentration. Because radon decays, the canister must reach the lab within the time stated on the kit.
- Alpha-track detectors contain a small piece of special plastic. Alpha particles from radon decay leave microscopic damage tracks, which the lab etches and counts. They suit long tests because they keep accumulating.
- Electret ion chambers hold a charged disc that loses voltage as radiation ionises the air inside. The voltage drop gives the average level.
- Electronic monitors let air into a small chamber, by diffusion or with a small pump, and count decay events continuously, giving hourly or daily figures. Consumer units such as the HOUND-2070 radon detector and the RM-60 portable radon detector are designed for ongoing home monitoring rather than a single lab report.
Setting up a radon test kit correctly
- Choose the room. Use the lowest level of the home that is regularly lived in or could be, such as a basement playroom or ground-floor bedroom. Avoid kitchens, bathrooms, laundry rooms and crawl spaces.
- Close up the house for short tests. For tests of a few days, keep windows and outside doors closed, apart from normal coming and going, for about twelve hours before and throughout the test. Do not run fans that bring in outside air.
- Position the detector. Place it about 20 inches (50 cm) or more above the floor, away from outside walls, windows, vents, fireplaces, direct sunlight and humid areas, somewhere it will not be moved.
- Open it only when ready. Charcoal canisters are sealed until use; remove the lid or tape as instructed and write the start time.
- Leave it alone. Do not move it or cover it during the test.
- Close and post promptly. At the end, reseal, record the stop time and post it the same day if possible.
A professional continuous monitor left by an inspector should not be moved or unplugged. Many detect tampering and the test may be invalidated.
If two kits came in the box, they are usually meant to be placed side by side, a short distance apart, as a duplicate test. Averaging the two results gives a more reliable figure, and a large difference between them tells you one was handled badly. Some programmes also send a sealed blank that you do not open; it travels with the others so the lab can correct for any radon picked up in transit.
Reading the result you get back
Labs report radon either in picocuries per litre (pCi/L), used in the United States, or becquerels per cubic metre (Bq/m3), used in most other countries. One pCi/L equals 37 Bq/m3, so a result of 2 pCi/L is about 74 Bq/m3. The US EPA recommends fixing a home at or above 4 pCi/L, about 148 Bq/m3, and considering it between 2 and 4 pCi/L. The World Health Organization suggests a reference level of 100 Bq/m3 where possible. Your national radon programme may use a different action level, so check it.
A single short test is a snapshot. Radon varies with weather, season and how the house is used. Our page on short-term versus long-term radon readings explains why a long-term test gives a truer annual average and when to follow a high short result with a second test.
Making sure the test is valid, and when to call a professional
Test results go wrong mainly because of setup, not the detector. Common problems include a canister left open in the cupboard before the start, a detector placed beside a window, a test that ended up in the post for too long, or one moved during a house viewing. If any of these happen, repeat the test rather than trusting the number.
For a property sale, many buyers and lenders expect a professional test with a continuous monitor, which records hourly data and shows if windows were opened; our guide on radon monitors for real estate inspections covers this. If results are above your country’s action level, contact a qualified radon mitigation contractor. Sealing cracks alone rarely fixes a high reading; the usual remedy is a sub-slab depressurisation system, which needs proper design. Radon is a leading cause of lung cancer after smoking, so a high result is worth acting on, but it is a long-term risk, not a reason to leave the house that night.
If a kit is sitting in a drawer
Check the expiry or use-by date on the packaging, then set it up this week in the lowest lived-in room, following the closed-house rule if it is a short test. Write the start time on the data sheet, leave it untouched for the full period, and post it the day it finishes so the result is valid.
Frequently Asked Questions
Does a radon test kit give off radiation?
No. Passive kits and monitors only detect radiation from the radon already in the air. They are safe to handle and to leave in a lived-in room.
Can I just look at a charcoal radon test to see the result?
No. Nothing visible changes on charcoal or alpha-track detectors. The lab has to count the radiation or the tracks, which is why they must be posted back.
What is the small box an inspector left in my basement?
During a property sale it is most likely a continuous radon monitor. It logs hourly readings and often detects movement, so leave it in place and keep windows closed for the stated test period.
How do I know if a radon kit is still usable?
Check the expiry date on the packaging and make sure the seal is intact. Charcoal kits that have been opened or stored past their date may give wrong results.
Is an electronic radon monitor better than a test kit?
It shows changes over time and lets you see the effect of mitigation, which a kit cannot. Consumer monitors are generally not used for official or sale-related reports, where a lab kit or professional monitor is expected.