Most ceiling-mounted detectors come off by turning the whole body anticlockwise, about a quarter turn, until it drops free of the mounting plate screwed to the ceiling. If it will not turn, look for a small locking tab, pin or screw on the edge and release it first. A hard-wired detector then hangs on a short cable with a plug-in connector, so switch off its circuit at the breaker before you unclip it; a monitored security detector needs the alarm company told or the system put in test mode. Note that a ceiling alarm labelled CO is a carbon monoxide detector, a life-safety device that should be replaced, not left off.
Work out what kind of detector you have
People often call the ceiling unit a CO2 detector, but in homes it is almost always a carbon monoxide (CO) alarm or a combined smoke and CO alarm. Carbon dioxide monitors, which track stale air from breathing, usually sit on a desk, shelf or wall at head height rather than on the ceiling. Our explainer on what CO2 is and why it matters sets out the difference. Read the label on the front or edge before you start.
| Type | How to recognise it | Extra step before removal |
|---|---|---|
| Battery-only, replaceable battery | No cable, battery door on the back | None |
| Battery-only, sealed long-life | Label says sealed or long-life battery, no battery door | Plan to deactivate it once it is down |
| Hard-wired mains with battery backup | Sits on a plate with mains wiring behind, often a green or amber power light | Turn off the breaker for that circuit |
| Hard-wired and interconnected | Several alarms in the house sound together on test | Turn off the breaker; expect other units to chirp |
| Wireless, monitored by a security company | Brand of the alarm company, linked to a keypad or app | Call the company or put the system in test mode |
| Plug-in or portable CO2 or CO monitor | Plugged into a socket or freestanding | Just unplug or lift it |
Taking it down, step by step
- Set up safely. Use a stepladder that lets you reach without stretching, on a level floor, and keep your head to the side of the detector rather than directly under it.
- Kill the power for wired units. Switch off the breaker or remove the fuse for the alarm circuit. If the circuit is not labelled, look for one marked smoke, alarms or lighting. The detector’s green power light should go out, though the backup battery may keep it working.
- Notify the monitoring centre if it is a security system detector, so a tamper signal does not lead to a call-out.
- Look for a lock. Many alarms have a tamper-resistant feature: a small tab you press with a screwdriver, a locking pin you pull out, or a tiny screw at the edge. Release it.
- Twist anticlockwise. Hold the detector body with your whole hand and turn it anticlockwise, usually less than a quarter turn. It should drop slightly when free of the plate’s hooks. Do not lever it with a screwdriver against the ceiling; that cracks the plate or the plaster.
- Unplug the connector on wired alarms. A short pigtail lead runs from the plate to the back of the detector. Squeeze the clip on the plug and pull it apart. Do not pull on the wires.
- Silence or deactivate it. Remove the battery from a replaceable-battery unit. Sealed units usually have a deactivation switch, tab or procedure described on the label; once done, many cannot be reactivated, so only do this when retiring the alarm.
Removing a backup battery from a mains alarm, or disconnecting one alarm in an interconnected chain, can make the others chirp until power and connection are restored.
If it is stuck, painted over or the plate comes away
Detectors that have been painted around often bond to the ceiling. Run a sharp utility knife around the edge to cut the paint film, then twist again. If it still will not move, the body may have been fitted the wrong way onto the plate, or the locking tab may still be engaged; look closely at the rim for a small slot.
If the whole mounting plate comes away with the detector, check whether it was fixed into plasterboard with no wall plugs. For a battery unit you can refit the plate with proper plasterboard fixings. For a wired unit, if the plate has pulled away and exposed mains connections in the ceiling, leave the breaker off and have an electrician refit it. Do not reconnect or handle loose mains wiring yourself unless you are qualified.
Putting a detector back up, or fitting its replacement
When refitting, line up the marks or arrows on the detector with those on the plate, push it up gently and twist clockwise until it clicks. Wired alarms will not seat with the connector trapped, so tuck the lead into the cavity first. Restore power, then press and hold the test button until the alarm sounds; on interconnected systems, every linked alarm should sound too. Many alarms are designed so they cannot be fitted to the plate with the battery missing, which is a deliberate safety feature.
If you are replacing a carbon monoxide alarm, install the new one according to its instructions; some CO alarms are designed for wall mounting rather than ceilings. Replacing a wired unit is simplest with the same brand, because the plate and connector are often brand-specific.
Do not leave the house without protection
If you took the alarm down because it was chirping, the chirp usually means a low battery or that the sensor has reached its end of life. Replace the battery or the whole unit the same day. Living without a CO alarm in a home with gas, oil or solid fuel appliances, or with an attached garage, leaves no warning for a gas that has no smell. Cover detectors with the plastic cap many come with, or remove them briefly, when sanding or painting, then refit them as soon as the work is done. If the alarm sounded its full four-beep pattern before you removed it, leave the building and call for help; taking it down does not remove the gas.
If you actually meant a CO2 monitor
A true carbon dioxide monitor mounted on a ceiling or high wall usually unclips from a bracket or unplugs from a USB or mains lead, with no safety implications. If you are moving it, place it at breathing height away from windows, vents and people’s faces, which our guide on choosing a CO2 monitor for home use covers. If you took it down to recalibrate, our page on how to calibrate a CO2 monitor explains the fresh-air method. A portable unit such as the SwitchBot CO2 detector can simply be moved from room to room instead of fixed in place.
Before you reach for the ladder
Read the label to confirm whether it is a carbon monoxide alarm, a smoke and CO combination, or a CO2 monitor, and check whether a cable or security system is involved. Switch off the breaker for wired units, then twist the body anticlockwise, and have the replacement or new battery ready so the alarm goes back up the same day.
Frequently Asked Questions
Why won't my detector twist off the ceiling?
Most often a locking tab or pin is engaged, or paint has bonded the edge to the ceiling. Release the tab and score around the paint line with a utility knife, then twist anticlockwise with your whole hand.
Will removing one alarm set off the others?
In an interconnected system, disconnecting one unit or its battery can cause chirps or a fault signal on others. Turning off the alarm circuit first and refitting promptly keeps disruption small.
How do I stop a removed detector from chirping?
Take out the battery if it has a battery door. Sealed models have a deactivation method on the label, often a switch or tab, which permanently disables them for disposal.
How do I dispose of an old carbon monoxide alarm?
Deactivate it, remove any replaceable battery, and take it to an electronics recycling point. Some smoke alarms contain a small radioactive source, so check the label on combination units and follow the disposal instructions.
Can I leave the detector off while I paint the ceiling?
For a short time, yes, but refit it as soon as the paint is dry. Never paint over a detector, as paint can block the vents and stop it sensing.