Skip to content
AkerminMeasure. Monitor. Improve. Compare Products
Learning Center

How to Set a Multimeter to Resistance Mode

You want to check a resistor, a heating element or a sensor, and you are not sure which dial position or range to use, or why the screen only shows 1 or OL. Here is the full setup.

As an Amazon Associate, Akermin earns from qualifying purchases. Product links on this page are affiliate links.

Resistance lives on the dial position marked with the omega symbol, which looks like a horseshoe; turn to it and press SELECT or FUNC if the display shows a diode or speaker icon instead of an ohm unit. Put the black lead in COM and the red lead in the jack marked V and omega. On a manual-ranging meter choose the lowest range above the resistance you expect, then with the circuit switched off touch the probes across the part: OL or a lone 1 means the value is above the range or the path is open, so step up a range.

What the meter does when it measures ohms

In resistance mode the meter becomes its own power source. It sends a small, known test current out through the red lead, through the part, and back into COM, measures the voltage that develops across the part, and divides one by the other using Ohm’s law. That is why the circuit must be unpowered: any outside voltage adds to or fights the meter’s own and the answer becomes meaningless, and on mains it can damage the meter’s input.

It is also why a part soldered into a board often reads lower than its marking. The meter’s test current takes every path between the two probe tips, including other components wired in parallel. Lifting one leg of the part gives you its true value.

Resistance and continuity usually share the same jack and often the same dial position. Continuity just adds a beeper and a fixed threshold; our explainer on what continuity is and why meters beep covers the difference.

Dial positions and ranges explained

What you see Meter type What to do
One omega position, no numbers Auto-ranging Turn to it; the meter picks the range and shows ohms, k-ohms or M-ohms
Omega shared with diode, continuity or capacitance Auto-ranging, multifunction Press SELECT until the ohm unit shows with no speaker or diode icon
Several positions like 200, 2k, 20k, 200k, 2M, 20M Manual-ranging Choose the lowest one above the value you expect
Separate low-ohm position Some advanced meters Use for values under a few ohms, such as windings and contacts

On a manual meter, each range is the maximum it will read. The 2k range reads up to about 1,999 ohms, the 20k range up to about 19.99 k-ohms, and so on. A lower range gives more decimal places, so it is more precise if the value fits.

The display units matter. A reading of 4.70 on the 20k range means 4.70 k-ohms, or 4,700 ohms. A reading of 470 on the 2k range means 470 ohms. Auto-ranging meters show a small k or M beside the number to tell you. Misreading that prefix is the most common ohms mistake: 1.2 M-ohms and 1.2 k-ohms look identical apart from one small letter, yet differ by a factor of a thousand.

Taking a resistance reading, step by step

  1. Remove power. Switch off and unplug the device, remove batteries, and wait for capacitors to discharge. Check with the DC and AC volts setting that nothing is live.
  2. Plug in the leads: black in COM, red in the V-ohm jack.
  3. Set the dial to ohms and press SELECT if needed.
  4. Null the leads. Touch the probe tips together and read the display. Good leads show a few tenths of an ohm. Note it and subtract it from low readings, or press REL or Delta, if your meter has it, to zero it automatically.
  5. Isolate the part. Disconnect at least one end of the component so other parts in the circuit are not in parallel.
  6. Probe across the part with firm contact on clean metal. Keep your fingers off both metal tips, because your body is a resistor of its own and adds a parallel path on high values.
  7. Read and range. If you see OL or 1, step to a higher range. If you see 0.00 or very few digits, step to a lower range for better resolution.

On an auto-ranging meter, steps 3 and 7 collapse into one because the meter picks the scale itself. Electrician-style meters such as the Fluke 117 list resistance alongside continuity and capacitance, so check the display icon to be sure you are on ohms and not one of its neighbours. A manual meter rewards you with a fixed scale once you know the range you need.

Checking that the ohms reading is right

The simplest reference is a new resistor with known colour bands. Worked example: a 4.7 k-ohm resistor with a gold tolerance band is good to 5 percent, so anything from about 4,465 to 4,935 ohms is a pass. If your meter shows 4.68 k, the meter and the resistor are both fine. A 1 percent resistor, with a brown tolerance band, narrows that window to about 4,653 to 4,747 ohms and makes a better reference.

Two other quick checks:

  • Shorted leads should read near zero. A few ohms means worn leads or dirty jacks.
  • Open leads should read OL steadily. A number that climbs slowly or flickers suggests contamination on the meter or a damp environment.

If readings wander even on a fixed resistor, our page on why multimeter readings jump around walks through the usual reasons, from a weak meter battery to a poor probe contact.

When the reading is misleading, or the meter is at fault

Some readings are correct but still misleading. Thermistors, heating elements and filament bulbs change resistance with temperature, so a cold reading can be very different from the working value. A motor winding of a fraction of an ohm can look like a short on a normal meter because lead resistance swamps it. Semiconductor parts behave differently depending on which way round the probes are.

Suspect the meter if a known resistor reads far outside its tolerance on more than one range, the reading never settles, or the meter shows ohms with the leads disconnected. Before blaming the meter, replace its battery, clean the probe tips and try a different set of leads.

A meter that has been connected across live mains while in ohms mode may have damaged input protection and can read wrongly afterwards. Do not rely on it for safety work. Use a meter with a suitable CAT rating, and if you are buying one, our guide on how to choose a digital multimeter explains what features matter, including auto-ranging and a relative zero function for low ohms.

Verify on a resistor you can read

Pull a resistor from a spare parts drawer or an old board, read its colour bands, then set your meter to ohms, null the leads and measure it. If it lands inside the tolerance band, you know the setting, the range and the meter are all correct, and you can measure the part that actually needs checking.

Frequently Asked Questions

What does OL mean in resistance mode?

OL means over limit: the resistance is higher than the range can display, or the circuit is open. On a manual meter, try the next range up. If it still reads OL on the highest range, the part is open or has very high resistance.

Why does my multimeter show resistance with nothing connected?

A healthy meter should show OL with open leads. A drifting number can come from damp, dirty leads, or touching the probe tips. If it persists with clean dry leads, the meter may need service.

Can I measure resistance in a circuit?

Only with power off, and even then parallel parts will usually make the reading lower than the component's true value. For an accurate result, lift one end of the component. In-circuit readings are fine for quick checks of switches and wires.

Does it matter which way round the probes go?

Not for ordinary resistors, wires or heating elements, which read the same both ways. For diodes, transistors and electrolytic capacitors it matters, because the meter's test voltage has a polarity. Use diode mode for semiconductors.

How do I measure very low resistance accurately?

Null the leads with the relative or zero function, use clean sharp probe tips, and press firmly. For values well under an ohm, a dedicated milliohm meter using four-wire measurement is far more accurate than a general multimeter.