A Culligan dealer, or the TDS tester that came with your water system, showed you a number in ppm and you want to know what it actually measures. Here is what happens at the probe and how to use the reading properly.

As an Amazon Associate, Akermin earns from qualifying purchases. Product links on this page are affiliate links.

A Culligan TDS meter works the same way as any handheld TDS tester: two metal electrodes pass a small alternating current through the water, and the meter measures how easily it flows. Dissolved minerals and salts split into charged ions that carry current, so more dissolved solids means higher conductivity; the meter corrects for water temperature and multiplies the conductivity by a conversion factor to show an estimate in ppm. It is excellent for comparing water before and after a softener or reverse osmosis filter, but it cannot see contaminants that do not form ions, such as most bacteria, many pesticides, PFAS or microplastics, and it does not tell you which minerals are present.

What happens at the probe

Pure water conducts electricity very poorly. Tap and well water conduct better because dissolved substances such as calcium, magnesium, sodium, bicarbonate, chloride and sulfate exist as charged ions. When the meter applies a voltage between its electrodes, the ions drift toward them and a current flows.

The meter uses alternating current rather than DC. A steady DC current would slowly coat the electrodes and change the water chemistry right at the probe, which drifts the reading. Switching direction many times per second avoids that.

From the measured current and the known shape of the probe, called the cell constant, the meter calculates electrical conductivity, usually in microsiemens per centimetre (uS/cm). Everything after that is arithmetic.

From conductivity to ppm

Conductivity changes with temperature, roughly a couple of percent per degree C, so the meter has a temperature sensor in the probe and converts every reading to what it would be at 25 degrees C. This is automatic temperature compensation, and it is why readings change for a few seconds after you dip the probe while the sensor settles.

The compensated conductivity is then multiplied by a factor, typically somewhere between 0.5 and 0.7, to estimate total dissolved solids in ppm. The factor depends on what the manufacturer assumes is dissolved: a sodium chloride basis gives a lower number than a mixed mineral basis for the same water.

Worked example: water with a conductivity of 400 uS/cm reads about 200 ppm on a meter using a factor of 0.5, but about 280 ppm on a meter using 0.7. Neither is wrong; they are using different assumptions. This is why two brands of TDS meter can disagree on the same glass and still both be working correctly.

If you want to compare readings between meters, or with a lab report, compare conductivity rather than ppm wherever possible. Many meters can switch to an EC or uS/cm display, and that number does not depend on the conversion factor, so it is the fairer like for like comparison. Always compare the same meter on the same samples when tracking a filter over time.

Using the reading on a softener or RO system

Water treatment dealers use TDS mainly to show how well a reverse osmosis system is working. The useful number is rejection, the percentage of dissolved solids the membrane removes:

Rejection = (1 – product TDS / feed TDS) x 100.

Worked example: tap water reads 320 ppm and the RO faucet reads 16 ppm. Rejection is (1 – 16 / 320) x 100 = 95 percent. Membrane makers state their own expected rejection, and when it falls noticeably below that over time, the membrane or a seal usually needs attention.

Reading What it usually means Next step
RO water much lower than tap Membrane working normally Record the numbers to compare later
RO water creeping up month by month Membrane ageing or fouling Check pre-filters and plan membrane change
RO water close to tap value Bypass, failed seal or membrane, or very low pressure Have the system serviced
Softened water about the same as hard water Normal; softeners swap calcium for sodium or potassium Use a hardness test strip instead
Sudden jump on a well Change in source water Get a lab water test

That softener row surprises many people. A water softener does not remove dissolved solids; it exchanges hardness ions for sodium or potassium ions. TDS stays about the same, so a TDS meter cannot show that a softener is working.

Some Culligan reverse osmosis faucets include their own quality monitor with probes in the water lines. Those work on the same conductivity principle, comparing feed and product water to judge the membrane.

What a TDS meter cannot tell you

  • Which substances are present. A ppm value from calcium is the same as one from sodium or nitrate.
  • Whether water is safe to drink. Lead at a dangerous level can be a tiny fraction of a ppm and barely move the reading. Bacteria, viruses, many organic chemicals and PFAS are not measured.
  • Hardness, chlorine or pH. These need their own tests.

If you have health concerns about your water, a certified laboratory test is the right tool, and on a private well it is the only way to know what is in it. A TDS meter is a monitoring tool for changes, not a safety certificate.

Be wary of demonstrations that go further than the meter can. A TDS reading on its own cannot prove that water is contaminated, and a high number is not automatically a health problem; mineral-rich spring and well waters often read high and are perfectly drinkable. Likewise, electrolysis demonstrations, where two electrodes turn tap water brown, show the electrodes corroding and reacting with normal minerals, not hidden toxins. If a sales visit relies on either, ask for a certified lab test of your water before buying any treatment system, and let the lab results, not the meter, decide what needs removing.

Checking your meter and taking clean readings

  1. Rinse the probe with the water you are about to test, or distilled water between samples.
  2. Pour the sample into a clean glass, not straight under a running faucet, so bubbles do not sit on the electrodes.
  3. Dip the probe to the marked depth, stir gently and wait until the number stops changing.
  4. To check accuracy, use a calibration solution of known value at room temperature. If the reading is off and the meter has a calibration screw or button, adjust it as the manual describes.
  5. Distilled water should read close to zero. A reading of several tens of ppm in fresh distilled water suggests a contaminated probe or a faulty meter.

Handheld meters that read both pH and conductivity, such as the VIVOSUN pH and TDS meter, can cover two tests at once. Our guide to pH meters covers the calibration care those need, and the VIVOSUN pH meter review looks at one combined unit in detail.

Test your own system

Measure your tap water and your filtered water in clean glasses, one after the other, and work out the rejection percentage. Write it down with the meter’s name, and repeat every couple of months; a steady number means the system is fine, and a climbing product reading is your early warning to book a service.

Frequently Asked Questions

Is a Culligan TDS meter more accurate than other brands?

TDS meters all measure conductivity, so accuracy depends on the probe, temperature compensation and calibration rather than the brand. Different brands may use different conversion factors, which explains differing ppm values on the same water.

What is a good TDS reading for drinking water?

There is no single safety line, because TDS does not identify harmful substances. Very high TDS can affect taste and scale, while reverse osmosis water often reads very low. For safety questions, a lab test is needed.

Why did my TDS go up after installing a water softener?

Softeners swap calcium and magnesium for sodium or potassium, which keeps dissolved solids and conductivity roughly the same, so a small rise or fall either way is normal. It does not mean the softener is failing; use a hardness test to check it.

Can a TDS meter detect lead?

Not in a useful way. Harmful lead levels are far too small to change the overall TDS reading noticeably. Lead requires a specific laboratory or certified test kit.

How often should I calibrate a TDS meter?

Check it against a calibration solution every few months, or whenever readings look odd. Keep the probe clean and dry between uses to slow drift.