A U-tube manometer is a clear tube bent into a U and partly filled with a liquid such as water, gauge oil or mercury. When one leg sees a higher pressure than the other, the liquid is pushed down on that side and up on the other until the weight of the raised column exactly balances the pressure difference. That difference is given by pressure = density x gravity x height difference, so the height between the two liquid surfaces is a direct measure of pressure, which is why the reading is often given in inches or millimetres of water column. Read the total difference between both surfaces, at eye level, at the bottom of the curved meniscus.
The balance at the bottom of the U
Picture the liquid at rest with both legs open to the air. Both surfaces see the same atmospheric pressure, so they settle at the same height. Now connect one leg to a slightly higher pressure, such as a gas line or a pressurised duct. That extra pressure pushes the liquid down in that leg and up the other.
The liquid stops moving when the pressure at the bottom of the U is the same from both sides. On the high pressure side, that is the applied pressure plus the weight of a shorter column. On the open side, it is atmospheric pressure plus the weight of a taller column. The extra height on the open side is supported exactly by the pressure difference. In symbols, delta P = rho x g x h, where rho is the liquid density, g is gravitational acceleration and h is the vertical height between the two surfaces.
Because only the vertical height matters, the tube’s width and shape do not change the reading, as long as both legs have the same bore. A wider tube just needs more liquid to move.
A worked example in real units
Water has a density of about 1,000 kg per cubic metre and g is about 9.81 m per second squared. A height difference of 1 inch, which is 0.0254 m, gives:
delta P = 1,000 x 9.81 x 0.0254 = about 249 pascals.
That is why one inch of water column, written in WC, equals roughly 249 Pa. A natural gas appliance with a manifold pressure of 3.5 in WC is therefore at about 3.5 x 249 = 872 Pa above atmosphere, which is only about 0.13 psi. Low pressures like these are exactly what U-tubes are good at, because a fraction of a psi produces an easily read column of liquid.
Change the liquid and the scale changes with it. Mercury is about 13.6 times denser than water, so the same pressure difference raises a mercury column to only about one thirteenth of the height of a water column. That suits higher pressures, but mercury is toxic and largely replaced now by digital gauges and safer fluids.
| Height difference | Water (Pa) | Gauge oil, SG 0.83 (Pa) | Mercury (Pa) |
|---|---|---|---|
| 1 in | about 249 | about 207 | about 3,386 |
| 10 mm | about 98 | about 81 | about 1,334 |
| 100 mm | about 981 | about 814 | about 13,340 |
The gauge oil column is an example only; always read the specific gravity printed on your manometer’s scale and use the fluid it was made for.
Reading one correctly, step by step
- Hang the manometer truly vertical. A tilted U-tube reads high, because the liquid travels further along the tube for the same vertical rise.
- With both legs open to the air, set zero by sliding the scale or adjusting the fill so both surfaces line up with the zero mark.
- Connect the pressure source to one leg with clean tubing and no kinks. Leave the other leg open for gauge pressure, or connect it to a second point for differential pressure.
- Let the liquid settle; with a fluctuating source like a running fan, wait for an average position.
- Look at the surfaces with your eye level to them. Water and most gauge oils climb slightly up the tube wall and dip in the middle; read the bottom of that curve, called the meniscus. Mercury curves the other way, so read its top.
- Read the full height difference between the two surfaces. On a scale with zero in the middle, add the rise in one leg to the fall in the other. On a compensated single-reading scale, follow the instructions printed on it.
The commonest beginner mistake is reading only one leg, which gives half the true pressure on a plain scale.
Variations you will meet
- Inclined manometer. One leg is tilted at a shallow angle, so a small vertical rise moves the liquid a long way along the tube. That spreads the scale out for very low pressures, such as duct static or chimney draft. It must be levelled carefully, because a small tilt error is magnified.
- Well type manometer. One leg is replaced by a wide reservoir, so its level barely moves and you read a single column. The scale is adjusted to compensate.
- Radon system manometer. The small U-tube on a radon mitigation pipe shows the suction the fan creates. Unequal levels mean the fan is pulling; equal levels usually mean it has stopped.
- Digital manometer. An electronic pressure sensor replaces the liquid, displays several units and can log. Models such as the EHDIS dual-port digital manometer read differential pressure through two ports like a U-tube, without fluid to spill or level.
For HVAC work, our guide to manometers for HVAC technicians covers liquid and digital options, and our comparison of differential pressure meters helps when you need low-range resolution.
Limits, errors and safety
A clean, level U-tube with the correct fluid is accurate enough to serve as a reference for checking digital meters, because it relies only on density and height. Its practical limits are:
- Reading resolution: you cannot read much better than a millimetre or so by eye, which is coarse for very low pressures.
- Temperature: liquid density changes slightly with temperature, a small effect for most field work.
- Dirty tubes: film and bubbles distort the meniscus and can split the column.
- Over-pressure: too much pressure blows the liquid out of the open leg, onto equipment or into a gas line. Some manometers include traps for this reason.
- Pulsation: fans and burners make the column bounce, which you have to average by eye.
On gas appliances, a manometer only tells you pressure. Opening a test port means you must refit and leak test it afterwards. If you smell gas, leave the building and call your gas utility from outside. Adjusting gas regulators is work for a licensed gas fitter in most places.
See it for yourself
Next time you have a U-tube in front of you, zero it with both legs open, then blow very gently across, not into, one open end, or apply a small pressure with a syringe, and watch the two surfaces move equal amounts in opposite directions. Add those two movements together and you have the pressure in inches or millimetres of that liquid.
Frequently Asked Questions
Why is pressure measured in inches of water?
Because a U-tube with water shows pressure directly as a height. One inch of water column equals about 249 Pa, a convenient unit for the small pressures in gas appliances, ducts and chimneys.
Does the diameter of a U-tube manometer matter?
Not for the reading, as long as both legs have the same bore. Only the vertical height difference sets the pressure. Very narrow tubes can suffer from capillary effects, which is why manometers use a reasonable bore.
What liquid is used in a U-tube manometer?
Water, coloured gauge oils and historically mercury are common. The scale is made for one specific liquid density, so always refill with the fluid the manufacturer specifies.
Can a U-tube manometer measure vacuum?
Yes. Connect the suction to one leg and the liquid rises on that side. The height difference shows how far below atmospheric pressure the connected point is, as on a radon fan system.
Why do the levels on my radon manometer look equal?
Equal levels usually mean there is no suction, so the fan may be off, failed or disconnected. Check the fan and its power, and contact a radon mitigation professional if it is not running.