Skip to content
AkerminMeasure. Monitor. Improve. Compare Products
Learning Center

How to Read Ohms on a Digital Multimeter

You have set your multimeter to the ohm symbol and touched the probes to something, and now the screen shows a number with a small k, an M, or just OL. Here is how to turn that into a real resistance value and know whether it is right.

As an Amazon Associate, Akermin earns from qualifying purchases. Product links on this page are affiliate links.

Turn the circuit off, set the dial to the ohm symbol, plug the black lead into COM and the red into the socket marked with the ohm symbol, then touch the probes across the part. Read the number together with the small prefix beside it: no prefix means ohms, k means thousands of ohms and M means millions, so 4.70 with a k is 4,700 ohms. OL means the resistance is higher than the current range can show, or the circuit is open; on a manual-ranging meter, switch to a higher range until a number appears. For very small readings, short the probes together first and subtract that lead resistance.

What the meter is doing when it measures resistance

In resistance mode the meter supplies a small, known current from its own battery through the probes, measures the voltage that appears across the part, and calculates resistance using Ohm’s law, R = V / I. That has three practical consequences:

  • The circuit must be unpowered. Any outside voltage adds to or fights the meter’s tiny test voltage and produces a nonsense reading, and on live mains it can damage the meter or injure you.
  • The meter measures everything between the probes. If the part is still connected in a circuit, other components in parallel give the current another path, and the reading comes out lower than the part’s true value.
  • The meter’s battery matters. A weak battery can make resistance readings inaccurate before it affects anything else, so a low-battery symbol is worth acting on.

Capacitors also need care. A charged capacitor in the circuit makes readings drift as the meter charges or discharges it. Switch off, wait, and discharge large capacitors safely before measuring.

Decoding what is on the display

Display shows It means In plain ohms
0.4 with the ohm symbol 0.4 ohms; usually just the probe leads 0.4 ohms
220.3 ohms No prefix, so ohms 220.3 ohms
4.68 k ohm k is kilo, times 1,000 4,680 ohms
99.6 k ohm Kilohms 99,600 ohms
1.002 M ohm M is mega, times 1,000,000 1,002,000 ohms
OL or 1 at the far left Over limit: above the range, or an open circuit Higher than range, or infinite
Reading that keeps changing Capacitor charging, poor contact, or touching the probes with fingers Not yet a valid reading

Watch the prefix closely; it is printed small, and lower-case k and capital M are easy to miss. Auto-ranging meters change it themselves. A meter such as the BSIDE 9999-count auto-ranging multimeter picks the best range automatically and shows the unit beside the number, so you only have to read it. On older or basic meters, “1” alone at the left of the display is the traditional over-range indication, the same as OL.

Taking a resistance reading, step by step

  1. Switch off and isolate. Turn off power and unplug the device. For best accuracy, lift at least one leg of the component out of the circuit.
  2. Set the meter. Turn the dial to the ohm symbol. On multi-function positions, press the mode or select button until the ohm symbol appears.
  3. Plug in the leads. Black to COM, red to the socket marked with the ohm symbol, usually shared with volts. Never use the amps socket for resistance.
  4. Short the probes. Touch the tips together. A healthy meter and leads read a fraction of an ohm. Note this number, or use the relative or zero function if your meter has one.
  5. Choose a range if your meter is manual-ranging. Start above the value you expect: for a resistor marked 4.7 k, use the 20 k range. If it shows OL, go up; if it shows only a few digits, go down for better resolution.
  6. Measure. Hold the probes firmly on clean metal, without touching the metal tips with your fingers, and wait for the reading to settle.
  7. Correct and compare. For readings under about 10 ohms, subtract the lead reading. Compare the result with the expected value and its tolerance.

Manual ranges show the maximum value at each setting. On a basic 2,000-count meter such as the backlit 2,000-count digital multimeter, the 2k range tops out at 1.999 k ohm, so a 2.2 k resistor would show OL on 2k and must be read on the 20k range.

Is the reading right? Checks with known values

Resistors are marked with a nominal value and a tolerance. A 4.7 k resistor with 5 percent tolerance can legitimately measure anywhere from about 4.47 k to 4.94 k. A 1 percent part should be within 4.65 k to 4.75 k. So a reading of 4.68 k is correct, not faulty.

  • Known-resistor test. Keep a few new 1 percent resistors, such as 100 ohm, 10 k and 1 M, and measure them now and then. If the meter agrees within its accuracy specification plus the resistor tolerance, it is reading correctly.
  • Probe-short test. Shorted probes should read well under an ohm. A reading of several ohms or a wandering value means a worn lead, a loose plug or dirty tips.
  • Finger test for high values. When measuring megohms, touching both probe tips with your fingers puts your body’s resistance in parallel and pulls the reading down. Hold the probes by the insulated grips only.
  • Stability. If the last digit wanders by one or two counts, that is normal; if the reading swings widely, the cause is usually contact or interference, covered in why multimeter readings jump around.

Continuity mode is related but different: it beeps below a low threshold rather than giving a precise value, and is faster for checking wires and fuses. What continuity is and why meters beep explains when to use it instead.

When the ohms reading is misleading or the meter is at fault

  • Reads low in circuit. Parallel paths through other components. Lift one leg and measure again.
  • Diodes and transistors give strange values. Semiconductor junctions conduct one way. Use the diode test function instead.
  • OL on something that should conduct. Check the leads are in the right sockets and the dial is on ohms, then test a known resistor. If the known resistor also reads OL, the meter or a lead is faulty.
  • Every reading slightly off. Replace the meter’s battery first. Some meters also have an internal protection component on the ohms circuit that can be damaged by measuring a live circuit; if a fresh battery does not fix it, the meter needs repair or replacement.
  • Insulation and earth resistance. A multimeter’s ohms range uses a low test voltage, so it cannot judge cable insulation or earth electrodes. Those need dedicated testers.

Never measure resistance on a live circuit, never use ohms mode to check whether a circuit is dead, and use a voltage test for that instead. For choosing a meter with the resolution and safety rating you need, see how to choose a digital multimeter.

Measure a known resistor now

Take a resistor whose value you know, ideally a new 1 percent part, short your probes to note the lead resistance, then measure the resistor out of circuit. If the result, minus the leads, falls within the resistor’s tolerance, you can trust your meter and your reading method on everything else you test today.

Frequently Asked Questions

What does OL mean on a multimeter in ohms?

OL means over limit. The resistance is higher than the current range can display, or there is no connection at all. On manual meters, switch to a higher range; if it still shows OL on the highest range, the circuit is open.

What does k mean on a multimeter?

It means kilohms, thousands of ohms. A display of 2.2 with k is 2,200 ohms. M means megohms, millions of ohms.

Why does my multimeter not read zero when the probes touch?

The probe leads and their contacts have a small resistance, typically a fraction of an ohm. Subtract that from low readings or use the meter's relative function to zero it out.

Can I measure resistance with the circuit powered on?

No. The meter supplies its own test current, so outside power corrupts the reading and can damage the meter. Switch off, unplug and discharge capacitors first.

What is a good resistance reading?

It depends entirely on the part. A good reading is one that matches the component's marked value within its tolerance, or matches the manufacturer's specification for a coil, element or sensor. A wire or closed switch should read near zero.