Each segment of the dial selects a quantity: V with a straight line is DC volts, V with a wavy line is AC volts, A is current, the Omega symbol is resistance, and a sound-wave or diode symbol is continuity or diode test. On a manual-ranging meter, the numbers inside each segment are the highest value that range can show, so pick the smallest range that is still above what you expect, or start high and step down. Always check which jacks the leads are in: volts and ohms use the V/Ohm jack, while current uses a separate A or mA jack and the meter must be connected in series.
The symbols around the dial
| Symbol | Measures | Typical use |
|---|---|---|
| V with a straight line and dashes, or VDC | DC voltage | Batteries, car systems, solar panels, electronics |
| V with a wavy line, or VAC | AC voltage | Wall outlets, transformers, appliance supplies |
| mV | Millivolts, a low voltage range | Sensors, thermocouples, small signals |
| A, mA, uA with straight or wavy line | DC or AC current | Current draw of a circuit, in series only |
| Omega | Resistance in ohms | Resistors, heating elements, sensors, with power off |
| Sound-wave or speaker icon | Continuity, beeps below a low resistance | Fuses, wires, switches |
| Arrow into a bar (diode) | Diode forward voltage | Diodes, LEDs, rectifiers |
| Capacitor symbol, F or nF | Capacitance | Capacitors, removed or discharged |
| Hz | Frequency | Mains frequency, signals |
| hFE | Transistor gain | Small transistors in a socket |
| NCV | Non-contact voltage detection | Quick presence check near a live wire |
The continuity function is explained in more depth in what continuity is and why meters beep.
What the numbers inside each segment mean
On a manual-ranging meter, the voltage section might read 200m, 2, 20, 200 and 600. Each number is the full-scale limit of that position. Set to 20, the meter can show up to about 19.99 volts with two decimal places. Set to 200, it can show up to about 199.9 volts but only one decimal place.
The rule is to choose the lowest range that is still higher than what you expect, because that gives the most resolution. Measuring a 9 volt battery, choose 20, not 200 and not 2. If you have no idea what voltage is present, start at the highest range and step down.
If the reading is too big for the range, the display shows a “1” on the left with nothing after it, or “OL”. That is not a fault; it means over limit, so move up a range. The same applies to ohms: k means thousands and M means millions, so 20k is up to twenty thousand ohms.
An autoranging meter has only one position per quantity and picks the range itself. Read the small unit letters on the screen, mV, V, k-ohm, M-ohm, because the decimal point moves as it changes range. The Klein Tools MM325 is a manual-ranging meter, so its dial shows these range numbers, while most pocket autoranging meters such as the ALLOSUN pocket multimeter show only the function symbols.
The jacks matter as much as the dial
- COM is the black lead, always.
- V Omega, often also marked with diode and Hz, is the red lead for voltage, resistance, continuity, diode and usually capacitance.
- mA or uA is for small currents and is usually fused at a low value.
- 10A or 20A is for large currents and often has a time limit printed next to it, such as a maximum number of seconds of continuous measurement.
The most common way to destroy a fuse, or a cheap meter, is to leave the red lead in an amps jack and then touch the probes across a voltage source. In the amps jack the meter is nearly a short circuit. After any current measurement, move the red lead back to the V jack immediately.
Some meters help by beeping or flashing a warning if the leads are in the amps jack while the dial is on volts. Do not rely on it. Make a habit of glancing at both the dial and the jacks before every measurement, the same way a driver checks mirrors. If a meter suddenly reads zero on every current measurement, the internal current fuse has most likely blown; replace it only with the exact fuse type and rating listed in the manual, because a wrong fuse removes the meter’s protection against a short circuit.
A safe routine for setting the dial
- Decide what you are measuring and whether it is AC or DC.
- Turn the dial to that function before touching the circuit, never while the probes are connected to a live source.
- On manual meters, choose a range above the expected value. On autoranging meters, wait for the reading to settle.
- Put the leads in COM and the correct red jack.
- For resistance, continuity, diode and capacitance, switch the circuit off and discharge capacitors first. Measuring ohms on a live circuit gives false readings and can damage the meter.
- For current, break the circuit and insert the meter in series. If you only need to know current in a mains cable, a clamp meter is safer; see multimeter versus clamp meter.
- Read the display, including the unit and any negative sign. A minus on DC volts simply means the leads are reversed.
Checking the meter and the dial setting
Before measuring something you care about, verify on a known value. A fresh AA battery should read about 1.5 to 1.6 volts on the 2 or 20 V DC range. Touching the two probe tips together on the lowest ohms range should read close to zero, usually a fraction of an ohm for the leads. A resistor with color bands gives a quick resistance reference.
For mains work, test the meter on a known live outlet before and after testing the circuit you think is dead. That simple live, dead, live check catches a blown fuse, a wrong dial position or a broken lead. On AC, phantom readings of a few volts on a disconnected wire are normal on high impedance meters and are explained in why ghost voltage appears on a multimeter.
Check the CAT rating printed near the jacks before measuring mains. A meter rated CAT III or CAT IV with a suitable voltage is designed for household distribution circuits; an unmarked meter or one with cracked leads should not be used on mains at all. Work inside a panel or on hard-wired circuits is a job for a licensed electrician if you are not trained for it.
Practice on something harmless first
Take a fresh battery, a resistor and a length of wire, and measure each one on the correct dial position and on one wrong position. Seeing the meter show OL, a negative sign, or a beep on purpose teaches the dial faster than any chart, and it is far better to learn that way than on a live outlet.
Frequently Asked Questions
What does 20k mean on a multimeter dial?
It is a resistance range that can display up to about twenty thousand ohms. A 4.7 kilo-ohm resistor would read 4.70 on that range.
Why does my multimeter show 1 on the left?
On many manual meters a lone 1 at the left of the display means over range. Move the dial to a higher range until a proper number appears.
Which setting do I use for a wall outlet?
AC volts, the V with a wavy line, on a range above the expected mains voltage, with leads in COM and V. Use only a meter with an appropriate CAT rating and good leads.
Which setting tests a car battery?
DC volts on the 20 V range, or the DC volts position on an autoranging meter. A fully charged, rested 12 volt car battery typically reads around 12.6 volts.
What is the 10A jack for?
It is for measuring large currents in series with a circuit. On a decent meter it is protected by its own high-energy fuse, but some cheap meters leave it unfused, and it usually has a time limit, so use it only for short measurements and move the lead back afterwards.