How to Reset a CO2 Alarm

Your CO2 monitor or controller is sounding, you have pressed buttons, and it keeps going off or will not go quiet. Here is how to silence it, reset it properly, and make sure it is not telling you something you should act on.

As an Amazon Associate, Akermin earns from qualifying purchases. Product links on this page are affiliate links.

Most CO2 alarms reset themselves once the reading falls below the alarm threshold, so the first step is to ventilate: open windows or doors, and on a grow room or cellar system, stop the CO2 supply. While the air clears, press the mute or alarm button to silence it; on many monitors a short press mutes and a long press opens alarm settings where you can raise or turn off the threshold. If it alarms in fresh air, power cycle it, then recalibrate it outdoors or run the factory reset from the manual. First, confirm it is a carbon dioxide (CO2) monitor and not a carbon monoxide (CO) alarm, which needs an emergency response instead.

Make sure it is CO2, not CO

The two names differ by one letter and the devices look similar, but the right response is completely different.

Device What it detects Typical alarm What to do
CO2 monitor or controller Carbon dioxide from breathing, plants, fermentation, dry ice or gas cylinders Beeps when a set ppm level is passed; usually adjustable Ventilate; use the steps on this page
CO alarm Carbon monoxide from faulty fuel-burning appliances, cars, generators Loud repeating pattern, often four beeps and a pause; label says CO or carbon monoxide Get everyone outside, call emergency services or the gas supplier
Smoke alarm Smoke particles Loud alarm, often three beeps and a pause Treat as a fire

A CO alarm has a test or reset button, but pressing it during a real alarm only silences it temporarily, and if CO is present it will sound again. Do not use the steps below for a CO alarm. Do not go back in until emergency responders or a qualified technician say it is safe.

Why the alarm keeps going off

A CO2 monitor sounds when its reading crosses a threshold. Household monitors are often set somewhere around 1,000 to 1,500 ppm, though some ship with a lower setting, and grow room controllers use whatever setpoint you choose. The background page on what a good indoor CO2 level is explains what these numbers mean for a room.

  • The reading is real and high. A closed bedroom with two people overnight, a meeting room, a car, or a room with a fermenting batch of beer can easily pass 1,000 ppm.
  • The threshold is low. Some monitors alarm at a level many homes reach daily, so the alarm feels constant.
  • The sensor has drifted. An NDIR sensor that reads high, or one stuck at its last calibration, alarms even in fresh air. The explainer on CO2 monitor accuracy covers drift.
  • A different alert. Many combined monitors also alarm on temperature, humidity, particles or low battery, using the same sound.
  • A real CO2 leak. In pubs, restaurants and breweries with beverage gas cylinders, or rooms using dry ice, a CO2 alarm can be a genuine safety warning.

Resetting the alarm, step by step

  1. Ventilate. Open windows and doors, run extract fans, and if it is a controller in a grow tent or cellar, close the CO2 supply valve or switch off the generator.
  2. Silence it. Press the mute, alarm or main button once. Many monitors silence for a set period, then sound again if the level is still high.
  3. Watch the reading fall. As fresh air comes in, the number should drop toward outdoor levels of roughly 400 to 450 ppm. Once below the threshold, the alarm clears.
  4. Adjust the threshold if needed. On many monitors, a long press opens settings where you can raise the alarm level or turn the buzzer off while keeping the display. Where a model allows it, the alert level sits in the device menu or, on smart monitors that link to home platforms such as the SONOFF AirGuard, often in the companion app; follow the manual for the exact sequence.
  5. Power cycle. If it alarms in fresh air or shows a frozen number, unplug it or remove the battery for a minute, then restart and let it warm up for several minutes.
  6. Recalibrate outdoors. If the reading is still high in fresh air, take it outside, away from people and exhaust, for at least the warm up period, then start the manual calibration. Most monitors calibrate to around 400 ppm. Full instructions are in how to calibrate a CO2 monitor.
  7. Factory reset as a last step. Many monitors restore default settings through a menu option or a long button hold. This also clears your custom thresholds.

Grow room controllers, such as the 0 to 5000 ppm CO2 controller, often have separate setpoints for day and night and for ‘plant’ and ‘human’ modes. An alarm in plant mode while people are in the room is a reason to switch the supply off before resetting anything.

Checking the reading is right afterwards

After a reset or calibration, confirm the monitor reads sensibly:

  • Outdoors, in open air away from traffic and people, it should settle around 400 to 450 ppm.
  • Breathe gently toward it from a short distance; it should rise noticeably within seconds to a minute, then fall back.
  • Indoors, the reading should fall after you open a window and rise slowly in a closed occupied room.

A monitor that stays high outdoors after calibration, never responds to breath, or jumps between unrelated values has a faulty sensor. Some cheap ‘CO2’ monitors do not contain a CO2 sensor at all and estimate an ‘eCO2’ figure from a VOC sensor; those cannot be calibrated meaningfully. The article on how CO2 monitors work explains how to tell.

When the alarm is a real hazard

In homes, CO2 rarely reaches dangerous levels, but some situations are different. Commercial cellars with beverage gas cylinders, breweries, rooms with dry ice, grow rooms fed by CO2 cylinders or burners, and confined spaces can see CO2 build up to dangerous levels from a leak. CO2 is heavier than air and can collect in low areas such as cellars.

For reference, US occupational limits set an eight-hour exposure limit of 5,000 ppm, and much higher short-term levels can quickly cause headache, dizziness, rapid breathing and confusion. If a CO2 safety alarm sounds in one of these settings, leave the area, ventilate from outside if possible, shut the gas supply only if you can do it without entering the affected space, and do not re-enter until the level is confirmed safe. Call the gas supplier or a qualified technician to find the leak. Never silence or disable a fixed CO2 safety alarm in a workplace to keep working.

Fix the cause, not just the noise

Once the alarm is quiet, look at when it went off: overnight in a closed bedroom points to ventilation, while an alarm in fresh air points to the sensor. Leave a window slightly open or add extract airflow for the first case, and do an outdoor calibration for the second, so you are not pressing the mute button every evening.

Frequently Asked Questions

How do I stop my CO2 monitor beeping at night?

Improve bedroom ventilation, for example by leaving a door or window slightly open, or raise the alarm threshold in settings. Many monitors also let you turn off the buzzer while keeping the display and data.

Will a CO2 alarm reset itself?

Usually yes. Most CO2 monitors stop alarming automatically once the reading falls below the threshold. Some require a button press to acknowledge the alarm first.

Why does my CO2 alarm go off with the window open?

The sensor may have drifted and need outdoor calibration, the threshold may be set very low, or the alarm may be for another reading such as humidity or low battery. Check what the display shows when it sounds.

Can I turn off the alarm on a CO2 monitor?

On most household monitors, yes, through the settings or app. On fixed safety alarms in commercial cellars and workplaces, no; those alarms exist to protect people from leaks.

Does a factory reset fix an inaccurate CO2 monitor?

Sometimes, if the problem was a bad calibration stored in memory. After the reset, calibrate it in fresh outdoor air. If it still reads wrongly, the sensor is likely faulty.