Skip to content
AkerminMeasure. Monitor. Improve. Compare Products
Review

JASLEEN 1mA DC Clamp Meter Review: One Pick, and Where It Sits

The JASLEEN clamp meter's headline claim is 1mA resolution on DC current, which is the range where parasitic draw work happens. This review covers what the listing publishes, what it does not, and whether that resolution is the reason to choose it over the other clamp meters already covered here.

As an Amazon Associate, Akermin earns from qualifying purchases. Product links on this page are affiliate links.

JASLEEN 1mA DC Clamp Meter Review: One Pick, and Where It Sits

JASLEEN · 1mA DC Clamp Meter True RMS 6000 Counts Auto-Ranging Digital Multimeter Capacitance Temperature Ohm Live Check V-Alert Low Impedance Voltage Tester for HVAC Automotive

View on Amazon

Price and availability are shown on Amazon and can change at any time.

This page reviews one product, the JASLEEN 1mA. Its distinguishing stated feature is 1mA resolution on DC current, which suits parasitic draw measurement on vehicles and small DC loads. It also publishes a dual line display, a low impedance (LoZ) mode for ghost voltage, V-Alert non-contact detection available under any function, and a back clip. The listing does not publish a safety category, an accuracy figure, a jaw size or a maximum DC current, so it cannot be compared on those grounds with the KLEIN TOOLS CL910 or the ETCR 3-Phase. Buy it if the 1mA DC resolution is the job; look at the KLEIN TOOLS CL910 if you need a published 2000A AC/DC range and a worklight, and at the ETCR 3-Phase if you need three-phase power recording rather than a handheld clamp.

The 1mA resolution claim, and the work it is for

Most clamp meters resolve DC current in the tens or hundreds of milliamps. That is fine for a starter draw or a winch, and useless for a parasitic draw, where the whole fault may be 30mA and the difference between a good circuit and a bad one is a handful of milliamps. The listing for the JASLEEN 1mA states 1mA resolution and sensitivity, and names parasitic draws as the example. That is the reason this meter exists.

Resolution is not accuracy. The listing publishes no accuracy figure for any range, so 1mA resolution tells you the display can show a 1mA step, not that a 1mA step is correct. For parasitic draw work that distinction matters: you are usually looking for a change, and a stable repeatable display is more useful than an absolute number. The listing does not publish a drift or stability figure either. A meter that resolves 1mA is the right instrument for the search; it is not a calibrated shunt.

The listing also does not publish a maximum DC current, a jaw opening or a conductor size. If you need to know whether the jaw closes around a battery cable or a starter lead, that answer is not in the bullets. Ask before buying, or treat this as a low-current instrument and keep a larger clamp for the high-current end.

Dual line display, LoZ and V-Alert: three functions that change how you work

The dual line display is stated to show AC voltage or current alongside frequency, or Celsius alongside Fahrenheit. In practice that means you can read a supply and its frequency in one look, or a temperature in both scales without changing mode. It is a convenience, not a measurement capability, but on a rooftop or under a dash it saves a button press and a second look.

Low impedance mode, LoZ, is the function that identifies ghost or stray voltages. A high impedance input can show a voltage on a conductor that is not really live, capacitively coupled from a neighbouring cable. LoZ loads the circuit and the ghost collapses. The listing states the mode exists; it does not publish the input impedance in LoZ, so you cannot tell from the bullets how hard it loads the circuit. That is a gap worth knowing about, because LoZ on a sensitive electronic circuit is not always the right tool.

V-Alert is stated to activate under any function, which means non-contact voltage detection is available without switching to a dedicated mode. That is genuinely convenient when you are moving between points. It is also a proximity indicator, not a measurement, and it does not replace a two-pole test or a direct contact measurement for proving dead. The listing does not publish a voltage threshold for V-Alert.

Where this sits against the ETCR 3-Phase, the KLEIN TOOLS CL910 and the ZMIWNIED FS899L on this site

The other clamp meters already covered here are different instruments with different jobs. The KLEIN TOOLS CL910 publishes a 2000A AC/DC auto-ranging range and a worklight. That is a high-current clamp for panel and motor work; it does not publish a 1mA resolution. If your work is mostly feeders and starters, the KLEIN TOOLS CL910 is the closer fit and the JASLEEN 1mA is the wrong end of the range.

The ETCR 3-Phase is not a handheld clamp at all. It records three-phase power quality over USB. If you need to log rather than spot-check, the JASLEEN 1mA does not do that, and the listing does not claim it does.

The ZMIWNIED FS899L is a multimeter rather than a clamp. It measures in series, which means breaking the circuit. For parasitic draw, breaking the circuit is exactly what you are trying to avoid, which is the argument for a clamp. The two are complementary: a multimeter for voltage and resistance, a clamp for current without interruption. For more on that split, see multimeter versus clamp meter.

The honest summary is that JASLEEN 1mA is the low-current DC specialist in this group, the KLEIN TOOLS CL910 is the high-current generalist, and the ETCR 3-Phase is a recorder. None of them substitutes for another.

What the listing never prints: safety category, accuracy, jaw size

Three numbers a buyer would want are absent. The listing publishes no safety category, no accuracy specification and no jaw opening. On a clamp meter, the safety category tells you what transient the instrument is built to survive, and without it you cannot place the meter against a known installation category. The listing also does not publish a DC current ceiling or a conductor size.

This is not a reason to avoid the product; it is a reason to ask the seller before you use it on anything other than low voltage DC. The listing’s own examples, parasitic draws and HVAC and automotive work, are consistent with low voltage use. Treat the published functions as the scope of the claim.

The listing also does not publish a battery type, an auto power off time, or a case. Those are the details that decide whether a meter survives a van, and they are not in the bullets. The back clip is stated, which helps, but a clip is not a case.

The buyer this clamp is for, and the buyer it is not

This is for the technician chasing a battery that goes flat overnight, the HVAC tech checking a small DC blower or control circuit, and the automotive diyer who wants to see current without pulling a fuse and inserting a meter. The 1mA resolution is the whole argument, and the dual line display and V-Alert make the rest of the day easier.

It is not for the electrician working in a panel on feeders, where a 2000A range and a published safety category matter more than milliamps; the KLEIN TOOLS CL910 is the better fit there. It is not for three-phase logging; the ETCR 3-Phase is. And it is not a substitute for a multimeter for voltage and resistance work, because a clamp measures current and the listing does not claim otherwise. If you are choosing a clamp for HVAC work specifically, the HVAC clamp meter guide sets out the questions; for DC motor checks, the DC motor clamp meter page covers the range question.

One caution the listing does not address: a clamp meter is not an alarm and not a safety device. It will not warn you of a live conductor except through V-Alert, which is a proximity indicator. Prove dead with the proper tester.

The verdict on the JASLEEN 1mA clamp

The JASLEEN 1mA is a specialist. The 1mA DC resolution is the reason to buy it, and the dual line display, LoZ mode and any-function V-Alert make it a practical daily carry for low voltage work. The listing does not publish a safety category, accuracy, jaw size or maximum DC current, so it cannot be judged against the KLEIN TOOLS CL910 on high-current work or against the ETCR 3-Phase on recording. If your job is finding a parasitic draw or reading a small DC circuit, this is the instrument in this group that names that job. If your job is panels, feeders or three-phase logging, it is the wrong tool and the other pages here are the honest answer.

1mA DC Clamp Meter True RMS 6000 Counts Auto-Ranging Digital Multimeter Capacitance Temperature Ohm Live Check V-Alert Low Impedance Voltage Tester for HVAC Automotive

1mA DC Clamp Meter True RMS 6000 Counts Auto-Ranging Digital

View on Amazon
ETCR ETCR8430 3-Phase Power Recorder USB Power Quality Analyzer | 6-Channel Voltage & Current Data Logger, 0.01V-600V, 1mA-400A

ETCR ETCR8430 3-Phase Power Recorder USB Power Quality Analyzer |

View on Amazon
Klein Tools CL910 Digital Clamp Meter, 2000A AC/DC Auto Ranging & Worklight | with TRMS, AC/DC Volt, Current, LoZ, Resistance, Continuity, Frequency, Duty-Cycle, Capacitance, More

Klein Tools CL910 Digital Clamp Meter, 2000A AC/DC Auto Ranging

View on Amazon
2026 Upgraded FS899L Digital Multimeter & 20 pcs Silicone Test Leads Kit, USB-C Rechargeable Color Screen, Auto 6000 Counts True RMS AC/DC Voltage Tester, NCV, CAT.III 1000V

2026 Upgraded FS899L Digital Multimeter & 20 pcs Silicone Test

View on Amazon

Products shown because their documented specifications fit this guide. Price and availability are on Amazon and can change.

Frequently Asked Questions

Does 1mA resolution mean the meter is accurate to 1mA?

No. The listing states 1mA resolution and sensitivity, which is what the display can show. It publishes no accuracy figure, so the correctness of a 1mA reading is not stated. For parasitic draw work you are usually looking for a change rather than an absolute value, which is where resolution helps most.

Will this clamp measure a starter motor or a whole panel?

The listing does not publish a maximum DC current or a jaw size, so it does not state a high-current capability. The KLEIN TOOLS CL910 on this site publishes a 2000A AC/DC range and is the high-current clamp in this group. Treat the JASLEEN 1mA as a low-current instrument until the seller confirms otherwise.

What is LoZ mode for, and can it damage a circuit?

LoZ, low impedance, is for identifying and eliminating ghost or stray voltages. It loads the circuit so a capacitively coupled voltage collapses. The listing does not publish the LoZ input impedance, so how hard it loads a sensitive circuit is not stated. Do not assume it is safe on every electronic circuit.

Does V-Alert replace a voltage tester for proving dead?

No. V-Alert is a non-contact detection function, stated to work under any function. It is a proximity indicator, not a contact measurement, and the listing publishes no voltage threshold for it. Prove dead with a proper two-pole tester or a direct contact measurement.

Is this a replacement for a multimeter?

No. A clamp measures current without breaking the circuit, which is its advantage for parasitic draw. A multimeter measures voltage and resistance in contact. The listing does not claim the meter replaces a multimeter. See multimeter versus clamp meter for the split.

What safety category is it rated to?

The listing does not publish a safety category. That is a real gap if you intend to use it near mains or in a panel. Ask the seller before relying on it for anything beyond the low voltage DC work the listing names.

Affiliate disclosure: Akermin earns a commission from qualifying Amazon purchases made through links on this page. Our editorial picks are based on documented specifications and owner feedback, not commissions.