There is no single legal limit for total VOCs in homes, but a widely used German indoor air guideline treats TVOC below about 0.3 mg/m3 as low, roughly 1 to 3 mg/m3 as noticeably elevated, and above about 10 mg/m3 as unacceptable for long stays. Many consumer monitors report in ppb or as an index instead, and their “high” bands are set by each manufacturer. Treat any reading that stays well above your home’s usual baseline, or above your monitor’s high band for hours, as high and find the source.
Why there is no simple VOC limit
VOC is not one gas. It is a family of hundreds of carbon compounds, from fairly harmless ones like ethanol to irritants such as formaldehyde and carcinogens such as benzene. A total VOC (TVOC) number adds them together as if they were the same, which is useful for spotting problems but cannot tell you how toxic the mix is. That is why health agencies publish limits for individual compounds and only guidance bands for TVOC.
Instruments add a second layer of uncertainty. A metal oxide sensor in a home monitor reacts more strongly to some compounds than others, and its output is converted to a TVOC figure using an assumed reference mixture. A photoionisation detector reads in ppm or ppb relative to a calibration gas such as isobutylene. The same room can therefore produce different numbers on different devices. This is explained in more depth in VOC vs TVOC: what is actually being reported.
There is also a timing issue. Many metal oxide sensors use automatic baseline correction: they assume the cleanest air they see over a day or so is “normal” and scale everything else from there. In a home that never airs out, that baseline creeps up and the monitor can show a reassuring green band while the air is actually poor. In a home that ventilates well at night, the same device can make an ordinary cooking session look dramatic. So “high” on a consumer monitor often means “high compared with the cleanest air this sensor has recently seen”, which is useful for spotting change, but not a measurement you can compare against a published guideline without care.
TVOC guidance bands
The most commonly cited framework is the German Federal Environment Agency’s five-level TVOC guidance for indoor air, expressed in milligrams per cubic metre:
| TVOC (mg/m3) | Rough level | Suggested response |
|---|---|---|
| Below about 0.3 | Low, no hygienic concern | Normal ventilation |
| About 0.3 to 1 | Still acceptable, slightly raised | Ventilate more, check for new sources |
| About 1 to 3 | Conspicuous, worth investigating | Ventilate and look for a source; limit long stays |
| About 3 to 10 | High, a clear problem | Find and remove the source, use only temporarily |
| Above about 10 | Unacceptable | Avoid occupying the room, investigate professionally |
Converting mg/m3 to ppb depends on the molecular weight of the reference gas, so there is no universal conversion. For a typical light VOC mix, 0.3 mg/m3 works out at very roughly 100 ppb, and many consumer monitors put their “good” band somewhere below a few hundred ppb and their “poor” band above a couple of thousand ppb. If your monitor uses an index scale instead, for example 0 to 500 or 1 to 5, its manual defines the bands and they are not directly comparable with other brands.
Reading your own monitor sensibly
- Learn your baseline. Leave the monitor in a normal living room for several days. Note the typical overnight low and daytime level. That is your reference, more useful than any chart.
- Look at duration, not peaks. A spike to a high band while cooking or cleaning that falls back within an hour is normal. A reading that stays high for days is the concern.
- Compare rooms and outdoors. Carry a portable unit such as the ATO portable VOC detector from room to room. A room much higher than the rest has a local source.
- Check humidity and temperature. Metal oxide sensors drift with humidity, and warm rooms off-gas more, so note both alongside VOC.
- Give new monitors time. Many metal oxide sensors need a burn-in period of hours to days and adapt their baseline automatically, so early readings may be unreliable.
If you need a number you can rely on more, for example after a renovation or for a tenant complaint, a more sensitive analyzer with traceable calibration, such as the Forensics VOC analyzer, which lists NIST traceable calibration and 0.01 ppm resolution, gives more consistent ppm values, though still relative to its calibration gas.
Typical readings in real situations
| Situation | What monitors commonly show | Is it high? |
|---|---|---|
| Ventilated home, no new materials | Low band, close to outdoor | No |
| Bedroom overnight with window shut | Rising through the night | Mildly, improve ventilation |
| Cooking or cleaning spray | Brief spike to high band | Short-term only |
| Freshly painted room | High for days, falling slowly | Yes, ventilate until it settles |
| New flooring or flat-pack furniture | Elevated baseline for weeks | Yes, ventilate and consider sealing |
| Garage with fuel or solvents | High, especially in warm weather | Yes, isolate from living space |
A practical rule: if the reading is in your monitor’s top band for more than a few hours with windows open, something in the home is releasing a lot. Patterns after decorating are covered in why VOC readings rise after painting or cleaning.
When a high reading needs more than ventilation
Some compounds matter far more than the total suggests. Formaldehyde, common in pressed wood products and some glues, has its own guideline values and can be irritating at levels that barely register on a TVOC sensor. If you notice eye or throat irritation near new furniture, a dedicated formaldehyde measurement is a better guide; see what formaldehyde is and how consumer monitors detect it.
Get professional help or leave the space if:
- Readings stay in the highest band for days despite ventilation.
- There is a strong chemical, fuel or solvent odour with no known source.
- People experience headaches, dizziness, nausea or breathing problems that improve away from home.
- You smell gas. That is a fuel gas emergency, not a VOC reading: leave, avoid switches and flames, and call the gas emergency line from outside.
An indoor air consultant can take laboratory samples that identify individual compounds and compare them with health-based limits, which no consumer monitor can do.
Turn the number into a decision
Write down your home’s normal overnight VOC reading this week, then treat anything that stays far above it, or in your monitor’s top band for hours with the windows open, as high. Walk the house with the monitor to find the room driving it and deal with that source first.
Frequently Asked Questions
Is 500 ppb TVOC high?
On many consumer monitors that sits in a moderate band, worth ventilating but not alarming. Because conversions depend on the reference gas, check where your own monitor places it and watch whether it falls back with fresh air.
Why do two VOC monitors show different numbers?
They use different sensors, reference gases and conversion formulas. Compare trends on the same device rather than absolute numbers across brands.
What is a safe VOC level for a baby's room?
Aim for readings in your monitor's lowest band and close to outdoor levels. Avoid painting or assembling new furniture in a nursery shortly before use, and ventilate well afterwards.
Does a high VOC reading mean mould?
Mould releases microbial VOCs, but most high readings come from products and activities. Look for visible damp, a musty smell and condensation before assuming mould.
Are workplace VOC limits the same as home guidance?
No. Occupational limits are set for individual chemicals, for healthy adults over a working day. Home guidance aims at much lower levels because people spend all day and night indoors.