Does Airthings Detect Mold?
Airthings cannot see mould spores or growth; it measures humidity, temperature and VOCs, and some models turn humidity data into a mould risk indicator.
Read More→Editorial desk
The Akermin Environmental Monitoring Desk researches hygrometers, weather stations, data loggers, sound and light meters. Every guide is written from manufacturer documentation, datasheets and published standards; Akermin does not run a test laboratory and never claims hands-on testing.
Airthings cannot see mould spores or growth; it measures humidity, temperature and VOCs, and some models turn humidity data into a mould risk indicator.
Read More→A vane anemometer measures air velocity from how fast its rotor spins and does not measure air density; you calculate density separately from pressure, temperature and humidity when you need mass flow.
Read More→A thermocouple produces a DC voltage in the millivolt range that rises with temperature difference and reverses polarity if the tip is colder.
Read More→A thermocouple works without any ground connection; grounding the junction to the sheath gives faster response but can create noise and ground loops, and a cable shield should be grounded at one end only.
Read More→A thermocouple is self-powered by the Seebeck effect, so it needs no supply, but whatever reads its millivolt signal usually does.
Read More→A thermocouple reports the temperature at its measuring junction, normally at the very tip of the probe, but only if enough of the probe is immersed and the wire along the temperature gradient is in good condition.
Read More→An open thermocouple usually reads full scale high or shows an error because of burnout detection; degradation and shorts usually read low.
Read More→A thermocouple carries no gas; it is a solid two-metal sensor that sends a few millivolts to the gas valve, while the separate pilot tube carries the gas.
Read More→A thermistor used for temperature measurement normally needs a fixed resistor, forming a voltage divider, or a constant current source, because an analog input reads voltage, not resistance.
Read More→A tachometer measures rotational speed, usually in revolutions per minute, using light, contact or a strobe.
Read More→A storm glass does not work as a barometer: its sealed chemical solution responds mainly to temperature, so the crystals reflect recent warming and cooling rather than air pressure or coming weather.
Read More→Every standard psychrometric chart shows dew point; you find it by moving horizontally from your air's state point to the saturation curve and reading the temperature there.
Read More→