Skip to content
AkerminMeasure. Monitor. Improve. Compare Products
Learning Center

Fireplace Pilot Light Won’t Turn On: Causes and Tests

You turn the knob to pilot, press it in, click the igniter, and nothing lights, or it flickers and dies the moment you let go. Each of those symptoms points to a different part, and a multimeter can tell you which.

Start by separating two problems. If the pilot never lights, the cause is usually gas, such as a closed supply valve, an empty propane tank or air in the line, a clogged pilot orifice, or an igniter that is not sparking at the right spot. If it lights but goes out when you release the knob, the thermocouple is not producing enough voltage to hold the safety valve open, which a multimeter on its DC millivolt range can confirm in a minute. If you smell gas at any point, stop, do not operate any switches, leave the house and call your gas utility from outside.

How a fireplace pilot keeps itself lit

Most gas fireplaces and inserts use a standing pilot with no mains power. When you push and hold the control knob at pilot, you are holding a safety valve open by hand so gas flows to the small pilot burner. The piezo igniter makes a spark that lights it. The pilot flame then heats two sensors: a thermocouple and a thermopile.

A thermocouple is a junction of two dissimilar metals that produces a small DC voltage when heated, typically in the tens of millivolts. That voltage powers an electromagnet in the gas valve which holds the safety valve open after you let go of the knob. If the pilot goes out, the voltage collapses and the valve shuts, which is what stops gas flowing into the room.

A thermopile is many thermocouple junctions stacked together and produces hundreds of millivolts. It powers the main gas valve when the wall switch, thermostat or remote calls for flame. That is why a weak thermopile gives a pilot that stays lit but a fire that will not come on. Some newer fireplaces use intermittent electronic ignition instead, which needs batteries or mains power and lights the pilot only when the fire is called.

Which part matches your symptom

Symptom Likely cause Check
No click from the igniter Broken piezo igniter or loose wire Look for a spark at the electrode in a darkened room
Click and spark, but no flame No gas: supply valve closed, tank empty, air in line, clogged orifice Confirm gas supply; hold knob longer to purge air
Spark lands away from the pilot hood Electrode bent or cracked insulator Visual check of spark position
Lights but goes out when knob is released Thermocouple weak, not in the flame, or loose at the valve Millivolt test of the thermocouple
Small, yellow or lazy pilot flame Dirty or partly blocked pilot orifice Flame should engulf the thermocouple tip
Pilot stays lit but fire will not come on Weak thermopile, faulty wall switch or remote, bad wiring Millivolt test of the thermopile and switch circuit

Lighting it correctly before blaming parts

  1. Read the lighting instructions, usually on a plate behind the lower grille. Follow those over any general guide.
  2. Make sure the gas supply valve to the fireplace is open; the handle is usually parallel to the pipe when open. On propane, check the tank level.
  3. Turn the control knob to off and wait at least five minutes, or the time your instructions give, so any gas can clear.
  4. Turn the knob to pilot, push it in and hold it. If the fireplace has been off for months, keep holding for up to a minute before sparking so air in the line is pushed out.
  5. Press the igniter repeatedly until the pilot lights.
  6. Keep holding the knob in for thirty to sixty seconds after the pilot lights, so the thermocouple heats fully, then release slowly.
  7. Turn the knob to on and use the switch or remote to light the main burner.

If it lights only while you hold the knob, the thermocouple circuit is the problem. If there is no flame after a minute of sparking with the gas confirmed on, the orifice or igniter is the likely fault.

Testing the thermocouple and thermopile

A multimeter with a DC millivolt range gives you numbers instead of guesses. Turn the fireplace off and let it cool before reaching in.

  1. Thermocouple, open circuit. Unscrew the thermocouple nut from the gas valve. Light the pilot and hold the knob in. Touch one meter lead to the tip of the thermocouple connector and the other to its copper tube. A healthy thermocouple usually produces in the region of 20 to 30 millivolts. A reading in single figures means it needs replacing.
  2. Thermocouple, under load. Specialist adapters let you read it while connected. The loaded figure is lower, and the valve will drop out once it falls below a few millivolts; most valve makers publish the minimum.
  3. Thermopile, open circuit. Disconnect the thermopile leads at the valve terminals marked for it, usually TP and TP/TH. With the pilot lit for a few minutes, a good thermopile typically produces several hundred millivolts, often quoted as 500 to 750.
  4. Thermopile, with the switch on. Reconnect, turn the wall switch on, and read across the thermopile terminals. A big drop under load, to below the minimum in the fireplace manual, points to a weak thermopile or resistance in the switch wiring.

Before replacing parts, check that the pilot flame fully surrounds the top few millimetres of the thermocouple and thermopile. A good sensor in a weak flame reads low. Also check the thermocouple nut at the valve; a loose connection loses millivolts and is fixed by snugging it a quarter turn past finger tight.

Cleaning the pilot assembly

Dust, lint and spider webs in the pilot assembly are a very common cause of a weak or absent flame, especially at the start of the heating season. With the gas off and the unit cold, remove the glass front as described in the manual, then use a soft brush and gentle compressed air around the pilot hood. Do not poke wire into the orifice, which can enlarge it and change the flame. If the orifice itself is clogged, a qualified technician should remove and clean or replace it.

When reinstalling the glass, make sure the gasket is intact and the clips are fully engaged. Direct-vent fireplaces rely on a sealed glass front to keep combustion products out of the room.

When to stop and call a gas technician

Stop and leave the house if you smell gas, which in natural gas and propane has an added sulphur or rotten-egg odour. Do not light anything, operate light switches or use a phone indoors; call the gas utility or emergency number from outside. Call a qualified gas technician or gas engineer if the pilot will not light with gas confirmed on, if a new thermocouple does not fix a pilot that drops out, if the flame is yellow and sooty, if the glass shows heavy white or black deposits, or if your carbon monoxide alarm sounds. Have a gas fireplace serviced periodically by a professional and keep a working CO alarm in the same area.

Your first check

Confirm the gas valve is open, wait five minutes with the knob off, then light the pilot following the plate instructions and hold the knob for a full minute. If it lights but drops out, test the thermocouple with a multimeter on millivolts; if it never lights, clean the pilot area or book a gas technician.

Frequently Asked Questions

Why does my pilot go out when I let go of the knob?

The thermocouple is not producing enough voltage to hold the safety valve open. It may be worn, not sitting in the flame, or loose at the valve. Holding the knob longer sometimes works for a while, but a replacement thermocouple is the usual fix.

Why does the pilot stay lit but the fireplace will not turn on?

The thermopile, wall switch, remote receiver or the wiring between them is likely at fault. Test the thermopile's millivolt output with the switch on; a low reading under load points to a weak thermopile or a poor switch connection.

Can I replace a fireplace thermocouple myself?

Some homeowners do, since it is usually a screw-on part. Gas appliance work is regulated in many places, though, and any disturbed gas fitting must be leak-tested. If you are unsure, have a qualified gas technician do it.

How long should I wait between attempts?

Follow the lighting plate, which commonly says to turn the knob off and wait about five minutes so any unburned gas can clear. Repeated quick attempts can let gas build up in the firebox.

Should I turn the pilot off in summer?