As an Amazon Associate, Akermin earns from qualifying purchases. Product links on this page are affiliate links.
For a quick reset, press and hold the test or silence button on the First Alert alarm for about 15 to 20 seconds; this clears most chirps and nuisance-alarm states. If that does not work, remove power completely: take out the battery, and on hardwired models switch off the breaker and unplug the harness, then hold the button for 15 to 20 seconds to drain stored charge, refit a fresh battery, restore power and press test. Never reset a carbon monoxide alarm that is sounding its emergency pattern; leave the building first and call for help.
What a reset clears, and what it cannot
A smoke or CO alarm is a small computer. Its microcontroller holds the current state in memory: normal, alarm, hush, low battery, alarm memory, fault or end of life. A capacitor on the board keeps that memory alive for a while even after the battery is removed, which is why an alarm sometimes chirps once more after you take the battery out, or carries on reporting low battery after you fit a new one.
A reset empties that capacitor and forces the alarm to start fresh, re-measuring the battery and sensor. It clears states caused by a past event: a weak battery that has since been replaced, a nuisance alarm, or a glitch after a power cut. It does not clear states caused by a present condition. If the sensor still sees smoke or CO, the alarm will return to alarm. If the life timer has expired, the end-of-life chirp or display comes back within minutes, because it is counted by the firmware, not stored as a fault.
Which reset fits your situation
| Situation | Reset method | Expect afterwards |
|---|---|---|
| Chirp after a battery change | Battery out, hold test for 15 to 20 seconds, battery back | Single chirp at power-up, then silence |
| Nuisance smoke alarm, air now clear | Press silence or test once | Quiet; returns to normal after the silence period |
| Hardwired system keeps chirping | Breaker off, harness out, battery out, hold test, reassemble | Green light on, quiet |
| CO alarm went off, source fixed by an engineer | Press the reset or test button as the manual describes | Display returns to zero or ready |
| ERR or fault code | Full power removal reset once | Normal operation, or the fault returns and the unit must be replaced |
| END or end-of-life chirp | No reset works | Replace the alarm |
Full reset, step by step
- Make sure there is no hazard. Check for smoke, heat or a burning smell. If a CO alarm is involved, confirm nobody has symptoms and that it is not sounding the four-beep pattern.
- Battery-only alarms: twist the alarm off its base, open the compartment and remove the battery.
- Hardwired alarms: switch off the breaker for the alarm circuit, twist the alarm off, press the release tab on the harness connector and unplug it, then remove the backup battery.
- Plug-in CO alarms: unplug from the outlet and remove the backup battery.
- Press and hold the test button for 15 to 20 seconds. You may hear a brief chirp as the last charge drains.
- Fit a fresh battery of the type on the label, checking the polarity marks. If unsure about the battery, a multimeter on DC volts should show roughly 9.3 V or more for a new 9V alkaline and about 1.5 V or more for a new AA.
- Restore power by reconnecting the harness and turning the breaker on, or plugging the CO alarm back in.
- Press and hold test until the alarm sounds, then release.
On interconnected systems, do this on the alarm that is chirping or that initiated the alarm. Resetting a unit that is only relaying the signal will not help. The initiating alarm usually has a different red light pattern from the others.
Sealed 10-year First Alert alarms have no removable battery. For those, a press and hold of the test button is the reset; if the alarm keeps chirping it has reached end of life or has a fault.
Resetting a CO alarm after it has gone off
If a First Alert CO alarm sounds the emergency pattern, the order of actions matters more than the reset. Get everyone out, call emergency services or your gas utility from outside, and wait until the building is cleared. Only after that should the alarm be reset, and only once the source has been found and fixed. Resetting it first just hides the warning.
Many First Alert digital alarms store a peak reading. Before you reset, press the peak or menu button and write down the highest value and the time. A qualified gas engineer uses that to judge how serious the leak was. A handheld meter like the Klein Tools ET110 CO meter lets an engineer or a homeowner spot-check appliances afterwards, though it does not replace a fixed alarm.
If the alarm goes off again after reset with no obvious source, do not keep resetting it. Leave, call for help, and have every fuel-burning appliance checked. For an alternative with its own display and backup battery, the First Alert plug-in CO alarm with digital display and the Kidde carbon monoxide detector review are useful references, and the First Alert plug-in CO alarm review covers First Alert’s own plug-in model.
When a reset will not fix it
- Chirp comes back within minutes: end of life, or the new battery is weak. Check the label date and the battery voltage.
- Random alarms with no smoke: a dusty chamber or a poor location near a kitchen, bathroom or vent. Clean the vents with a soft vacuum brush and compressed air, or move the alarm.
- No sound on test after reset: horn, button or board failure. Replace the alarm.
- Whole hardwired system chirping at once: possibly a supply problem. If the breaker trips or connectors look scorched, leave it off, fit temporary battery alarms, and call a licensed electrician.
- Age: smoke alarms are generally replaced ten years after manufacture, and CO alarms at the life printed on them.
Replace rather than reset repeatedly. An alarm that needs resetting every week is no longer dependable.
Drain it once, then judge
Take the battery out, hold the test button for a full 15 to 20 seconds, fit a battery you know is fresh and press test. If the alarm stays quiet for a day, the reset worked; if the chirp or fault returns, read the date on the back label and replace the unit rather than resetting it again.
Frequently Asked Questions
Where is the reset button on a First Alert alarm?
On most First Alert alarms the large test or silence button on the front doubles as the reset. Some CO alarms label it test/reset. The manual for your model shows which one to use.
Why does my First Alert alarm beep after I put in a new battery?
The alarm may still hold the old low-battery state, or the new battery may be weak or not fully seated. Do a full drain reset with the battery out and check the battery with a meter.
Can I reset a hardwired alarm without turning off the breaker?
A button press works for simple states, but a full reset needs the mains supply off and the harness unplugged. Switching off the breaker is also safer when handling the connector.
Will a reset stop the end-of-life chirp?
No. End of life is counted by the alarm's firmware and returns after any reset. Some models allow a temporary silence, but the alarm must be replaced.
How do I reset a First Alert alarm that is part of a wireless system?
Reset the unit that is chirping or initiated the alarm in the usual way. If it stops communicating with the others afterwards, follow the relinking procedure in its manual.