As an Amazon Associate, Akermin earns from qualifying purchases. Product links on this page are affiliate links.

Srliya · Digital Insulation Tester RCD Loop Test Multifunctional Full Auto Range Electrical Instruments Meter
View on AmazonPrice and availability are shown on Amazon and can change at any time.
The Srliya digital insulation tester is a specialist leakage switch, or RCD, tester. The listing states it measures tripping current, tripping time, loop, AC phase voltage from 0 V to 440 V and frequency from DC to 65 Hz, with selectable test currents of 10, 30, 100, 300 and 500 mA and multipliers of 0.5, 1 and 5. It stores 1000 test results and can upload them to a PC over USB 2.0. It suits an electrician or maintenance technician who regularly proves RCDs trip within the required time and current on fixed installations. It is the wrong buy for anyone who mainly needs insulation resistance testing, because the listing does not publish an insulation resistance range, test voltage or accuracy figure. Despite the title, the published functions describe an RCD and loop tester, not an insulation resistance tester.
What the Srliya listing actually promises, function by function
The title calls this a digital insulation tester, but the bullets describe a different instrument. The functions named are tripping current, tripping time, loop measurement, online voltage and frequency measurement of a leakage switch. Insulation resistance is not listed as a function, and no test voltage such as 250 V, 500 V or 1000 V is published. A buyer searching for an insulation tester should treat the title as loose wording and read the function list as the real specification.
The listed measurement ranges are AC phase voltage 0 V to 440 V and frequency DC, 45 Hz to 65 Hz. The electrical test positions are 10, 30, 100, 300 and 500 mA, and the test current multiplier can be set to 0.5, 1 or 5. Those are the numbers that matter for RCD testing, because a 30 mA RCD is expected to trip at its rated current and the multiplier lets you test at half, one and five times that value. The listing does not publish accuracy figures for any of these ranges, so a buyer who needs a calibrated reference should ask the seller for a declaration of conformity.
Storage is stated as 1000 groups of test results, uploaded to a PC through a USB 2.0 port. That is useful on a periodic inspection where you want a record of every RCD tested, but the listing does not say what software is supplied or what file format the upload uses. Do not assume the data lands in a spreadsheet without checking.
The tripping current and tripping time tests, and why the multiplier matters
An RCD is a safety switch that compares current going out on the live conductor with current returning on the neutral. When the difference exceeds its rating, it opens the circuit. A tester does two separate jobs: it ramps or steps current up to find the value at which the device trips, and it times how long the device takes to open once that current is applied.
The Srliya listing covers both. The test positions of 10, 30, 100, 300 and 500 mA correspond to common RCD ratings, and the 0.5, 1 and 5 multipliers let you check the half-rated current hold, the rated-current trip and the five-times trip. The five-times test is the one that exposes a slow device, because the time limit is tighter at higher current. The listing does not publish the time measurement range or its resolution, so you cannot tell from the page whether it will display to 1 ms or 10 ms. For a pass or fail decision against a stated time limit that gap matters, and you should ask before buying.
Loop measurement is listed as a function, but the listing does not publish the loop range or the test current used for it. Loop impedance testing on a live circuit is a different measurement from RCD tripping, and without a published range you cannot confirm it covers the fault loop values you work with. Treat the loop function as present but unspecified until the seller provides a datasheet.
Voltage, frequency and the CAT rating nobody publishes
The listing states AC phase voltage measurement from 0 V to 440 V and frequency from DC to 65 Hz. That voltage range covers single-phase domestic and commercial supplies in many regions, but it does not by itself tell you the category rating of the instrument. The CAT rating describes the transient energy the meter can survive, and it is the difference between a tool you can safely use at a distribution board and one you should keep away from it. The listing does not publish a CAT rating, an IP rating, a pollution degree or an overvoltage category. If you intend to work on the supply side of a main switch, that silence is a reason to ask the manufacturer directly, not to assume.
Frequency measurement down to DC is listed, which is unusual phrasing for a leakage switch tester and may simply reflect the meter’s general measurement mode. The listing does not explain what DC frequency means in practice. Do not build a test procedure around that bullet until the seller explains it.
For readers comparing this with a general-purpose meter, the site’s guide to electrical testers sets out the wider field. The Srliya is a narrow instrument by comparison, and that narrowness is the point.
Who this meter is for, and the buyer it is wrong for
This is for the technician who already owns a multifunction installation tester or a separate insulation resistance tester and wants a dedicated, compact RCD and loop tool for periodic verification. It is also for the maintenance electrician who tests the same set of leakage switches on a schedule and wants the results stored and uploaded rather than written on a pad. The 1000-group memory and USB 2.0 upload point at repeat testing and record keeping, not at one-off fault finding.
It is the wrong buy for three readers. The first is the homeowner or DIY buyer who wants to check a single RCD once. A plug-in RCD tester or a qualified electrician’s visit does that job without buying an instrument whose other functions you will never use. The second is anyone who needs insulation resistance testing, because the listing publishes no insulation test voltage or resistance range despite the product title. The third is the solar or PV installer, because DC insulation testing and PV array measurement are outside the published functions; the site’s insulation resistance testers guide covers that need properly.
If you need three-phase power quality recording rather than RCD verification, the Srliya is not a substitute. A power recorder such as the ETCR8430 covered elsewhere on the site answers a different question, and no RCD tester can replace it.
The maintenance and record-keeping the listing does not describe
Test instruments drift, and an RCD tester is only as good as its last check. The listing does not publish a calibration interval, a recommended verification method or a statement of accuracy, so the buyer has to establish those from the manufacturer or from local practice. A common approach is to verify the tester against a known good RCD or a calibration box at intervals set by your insurer or accreditation body. Do not assume the meter arrives with a calibration certificate unless the seller states one is included.
The USB upload is the other maintenance point. The listing says results can be uploaded to a PC through USB 2.0 but does not name the software or the operating system supported. Before relying on the memory for client records, confirm that you can export the data in a format you can archive. A stored result you cannot retrieve is not a record.
Battery type and battery life are not stated in the listing. For a tool that lives in a van, that is a practical gap: check what cells it takes and whether they are rechargeable before you commit.
The Srliya RCD loop tester: a narrow tool that should be bought for a narrow job
Buy the Srliya digital insulation tester if your work is RCD verification and you want tripping current, tripping time, loop, voltage and frequency in one compact unit with stored results and USB upload. The published test positions and multipliers cover common leakage switch ratings, and the 1000-group memory suits scheduled inspection work.
Do not buy it if you need insulation resistance testing, because the listing publishes no insulation test voltage or resistance range. Do not buy it as a first electrical meter, and do not buy it for PV work. The listing also leaves out accuracy, CAT rating, loop range, time resolution and battery type, so confirm those with the seller before you rely on the instrument for safety decisions.
Recommended Tools
Products shown because their documented specifications fit this guide. Price and availability are on Amazon and can change.
Frequently Asked Questions
Does the Srliya tester measure insulation resistance?
The listing does not publish an insulation resistance function, test voltage or resistance range. The title uses the phrase insulation tester, but the bullets describe RCD tripping current, tripping time, loop, voltage and frequency measurement. Treat it as an RCD and loop tester until the seller provides an insulation specification.
What RCD ratings can it test?
The listing gives test positions of 10, 30, 100, 300 and 500 mA and multipliers of 0.5, 1 and 5. That covers common 10 mA, 30 mA, 100 mA, 300 mA and 500 mA leakage switches at half, rated and five-times current. The listing does not state whether a ramping test is included.
Can I use it on three-phase systems?
The listing states AC phase voltage measurement from 0 V to 440 V and frequency from DC to 65 Hz. It does not describe a three-phase measurement mode, phase rotation or a three-phase loop test. Do not assume three-phase capability from the voltage range alone.
How do I get the stored results onto a computer?
The listing states that stored data can be uploaded to a PC through a USB 2.0 port, with capacity for 1000 groups of test results. It does not name the software, the operating system or the export file format. Ask the seller for those details before you plan to use the memory for client records.
Is the accuracy published?
No. The listing publishes ranges and test positions but no accuracy figure for voltage, frequency, loop, tripping current or tripping time. If you need a calibrated reference, request a specification sheet or declaration of conformity from the seller.
Is it safe to use at a distribution board?
The listing does not publish a CAT rating, overvoltage category, IP rating or pollution degree. Those are the figures that describe transient withstand and environmental protection. Without them, do not assume the meter is suitable for supply-side work; confirm with the manufacturer first.
Affiliate disclosure: Akermin earns a commission from qualifying Amazon purchases made through links on this page. Our editorial picks are based on documented specifications and owner feedback, not commissions.