Skip to content
AkerminMeasure. Monitor. Improve. Compare Products
Learning Center

How to Tell if a Multimeter Is Bad

Your meter is giving readings you do not trust, or no reading at all, and you cannot tell whether the circuit or the tool is at fault. These checks separate the two in about ten minutes.

As an Amazon Associate, Akermin earns from qualifying purchases. Product links on this page are affiliate links.

Short the two probe tips together on the ohms range: a healthy meter and leads read close to zero, while OL or a flickering value points to a broken lead. Then measure something you already know, such as a fresh AA cell or a wall outlet, and check the current-range fuses with the ohms function. If the leads, fuse and battery are all good and the meter still reads wrong on a known source, the meter itself is faulty and should be repaired or retired, especially if you use it on mains.

Why a meter fails quietly

A digital multimeter rarely dies in a dramatic way. More often one part of the measurement chain degrades and the display keeps showing numbers that look plausible. The chain has five links: the probe tips, the lead wires, the input jacks, the protective fuses and the measuring circuit with its battery. A fault in any one of them produces a wrong reading, but each fault has a different signature.

Lead wires flex thousands of times and the copper strands break inside the insulation, usually right where the wire enters the probe or the banana plug. The fuses protect the current ranges and blow when someone measures voltage with the red lead still in the amps jack, which is one of the most common mistakes made with a meter. A weak battery shifts the internal reference so that every range reads slightly off before the low-battery icon appears. Real failures of the measuring circuit are less common and usually follow an overload, a drop or water getting inside.

The point of testing in order is that the cheap, likely parts are checked first, and you only condemn the meter once those are ruled out.

Symptoms and what they usually point to

Symptom Most likely cause Quick confirmation
Reads OL or 0 on every range Broken lead or lead in the wrong jack Short the tips on ohms; wiggle the wire near each end
Voltage works, current reads zero Blown fuse in the A or mA circuit Ohms test across the fuse, method below
All readings a little high or low Weak battery Fit a fresh battery and remeasure a known source
Reading wanders or jumps Loose probe tip, dirty jacks, or a real noisy signal Clean jacks, try another set of leads
Shows a few volts on a dead wire Ghost voltage, not a fault Use a low-impedance mode or load the circuit
Blank or segments missing Dead battery, failed display, corrosion Fresh battery; inspect the battery contacts
Reads wrong after a bang or a spark Damaged input protection Known-value checks on every function; retire if any fail

Two of these are not faults at all. A reading that hops around can come from the circuit you are measuring, and our guide on why multimeter readings jump around covers that case. A few volts appearing on a disconnected wire is usually capacitive coupling from neighbouring live wires, which is explained in why ghost voltage appears on a multimeter.

Ten-minute bench check, in order

  1. Inspect the leads. Look for cracked insulation, exposed copper, bent tips and loose shrouds. Damaged leads are a shock risk on mains and should be replaced, not taped.
  2. Short-circuit test. Set the meter to the lowest ohms range or continuity, plug the black lead into COM and the red into the V/ohm jack, then press the tips together. A good set reads a fraction of an ohm, often a few tenths, and continuity beeps instantly. Flex each lead along its length while the tips touch. If the value jumps or the beep cuts out, that lead has a broken strand.
  3. Open test. Separate the tips. The display should show OL on ohms. A steady low number with the tips apart means contamination, moisture or an internal fault.
  4. Fresh battery. Replace the battery even if the icon is not showing. Many meters lose accuracy before they warn you.
  5. Known DC voltage. Measure a new alkaline AA. It should read a little above 1.5 V, typically around 1.55 to 1.6 V when fresh. A new 9 V battery usually reads slightly above 9 V. If the meter shows something far off, such as 1.2 V on a brand new cell, suspect the meter.
  6. Known AC voltage, only if you are trained and the meter is rated for it. A household outlet should read near your nominal supply voltage. Use leads with shrouded tips and hold them behind the finger guards.
  7. Fuse test. Put the red lead in the V/ohm jack set to ohms. Touch the other lead’s tip into the A or mA jack, so the meter measures through its own fuse. A good fuse reads a low resistance; OL means the fuse is blown. Some manuals give a different method, so follow yours where it differs.
  8. Diode and continuity functions. Test a known diode or LED: forward direction shows a voltage drop, roughly 0.5 to 0.7 V for a silicon diode, and reverse shows OL.

Confirming accuracy against something you trust

Passing the steps above tells you the meter works. It does not tell you how accurate it is. For that you need a reference. The simplest is a second meter that you trust: measure the same battery, the same outlet and the same resistor with both and compare. On a battery the two should agree within a few hundredths of a volt; on a resistor, within the tolerance printed on the resistor plus the meter’s own specified accuracy.

Precision resistors make good home references. A 1 percent 10 kilohm resistor should read between about 9.9 and 10.1 kilohm. Subtract the short-circuit lead reading when you measure low values, because half an ohm of lead resistance matters on a 10 ohm part but not on a 10 kilohm one. A bench instrument such as the Hantek HDM3065X bench multimeter with six and a half digit resolution is the kind of reference a workshop might keep for checking handheld meters.

For AC, remember that a basic average-responding meter and a true RMS meter can disagree on distorted waveforms, such as the output of a dimmer or a variable speed drive, even when both are working perfectly. Compare them on a clean source. The difference is covered in our explainer on what true RMS means on a multimeter.

When to repair, replace or stop using it

Replace the leads if they fail the flex test; that is the cheapest fix and solves a large share of complaints. Replace a blown fuse only with the exact type, current and voltage rating listed in the manual. A high-energy ceramic or sand-filled fuse is part of what keeps an arc inside the meter if you make a mistake on a powerful circuit. A cheap glass fuse of the same amps is not equivalent.

Stop using the meter on mains or any high-energy circuit if any of these apply:

  • it reads wrong on a known voltage after a fresh battery and good leads
  • the case is cracked, the jacks are loose, or there are scorch marks
  • it was used on a voltage above its rating, or it popped, sparked or smelled hot
  • it got wet inside and shows corrosion
  • it carries no category rating, or a rating below the circuits you work on

Category ratings describe how well the meter survives transient spikes, not just steady voltage. A meter marked CAT III 1000 V and CAT IV 600 V, such as the FS899L digital multimeter, is built for distribution-level work, while a meter rated CAT II is meant for appliance outlets and below. If your meter has failed, our guide to choosing a digital multimeter walks through what to look for in a replacement.

Calibrated professional meters that drift out of specification should go back to an accredited lab rather than be adjusted at home.

Do the short test first

Before you blame the circuit or buy a new meter, press the probe tips together on the ohms range and flex each lead while you watch the display. If that is clean, measure a fresh AA and check the fuse through the amps jack; one of those three steps finds the problem in most cases, and only a meter that fails on a known source with good leads and a fresh battery needs replacing.

Frequently Asked Questions

Can a multimeter give wrong readings without showing an error?

Yes. A weak battery, a partly broken lead or damaged input protection can all produce plausible but wrong numbers. That is why measuring a known source, such as a fresh battery or a precision resistor, is the only real proof.

Why does my multimeter read voltage but not current?

The current ranges are protected by fuses and the voltage range is not, so a blown fuse kills only the current function. Check it with the ohms range through the amps jack and replace it with the exact rated type.

How much resistance should test leads have?

A good pair usually reads well under one ohm when the tips are shorted, often a few tenths of an ohm. A value of several ohms, or one that changes as you bend the wire, means a damaged lead.

Is it safe to keep using a meter that was dropped?

Only after it passes the checks on a low-voltage known source, and the case and jacks are undamaged. If it reads wrong, rattles or has a cracked case, do not use it on mains.

Do multimeters need calibration?

Home meters are rarely calibrated, but a yearly comparison against a trusted reference is a sensible habit. Professional work that requires traceable results needs calibration by an accredited lab at the interval your quality system sets.