Something has stopped working and you suspect a fuse, but you cannot see the element, or it looks fine and you are not sure. A digital multimeter will settle it in under a minute if you use the right setting.

As an Amazon Associate, Akermin earns from qualifying purchases. Product links on this page are affiliate links.

A digital multimeter tests a fuse reliably. With the fuse removed and the meter on continuity or the lowest ohms range, a good fuse beeps or reads close to zero ohms, and a blown fuse shows OL or open. Where the fuse cannot be removed, you can measure voltage across it in a working low-voltage circuit: near zero volts means it is intact, while supply voltage across it means it has opened. Never use the amps setting to test a fuse.

Why a meter can see what your eyes cannot

A fuse is a deliberately weak conductor. Inside the body is a thin wire or strip sized to melt when current exceeds its rating for long enough. While it is intact, it is just a piece of metal with very little resistance. Once it has blown, there is a gap, and the resistance becomes effectively infinite.

Glass fuses sometimes show a broken wire or a blackened tube, but ceramic, sand-filled cartridge and many miniature fuses are opaque, and even glass ones can fail with a hairline break right at the end cap that you will not spot. The multimeter does not care what the fuse looks like. On continuity or resistance it pushes a small current through the fuse from its own battery and reports whether that current gets through. If you have not used the continuity function before, the explainer on what continuity is and why meters beep covers how the beep threshold works.

Readings for each kind of fuse

Fuse type Best test Good fuse reads Blown fuse reads
Glass or ceramic cartridge (electronics, appliances) Removed, continuity or ohms across the end caps Beep, or well under one ohm on most ratings OL or no beep
Very low current fuse (a few hundred milliamps or less) Removed, ohms Can read a few ohms because the wire is so fine; that is still good OL
Automotive blade fuse In place, using the two small test points on top, ohms with the circuit off, or DC volts to ground with the circuit on Near zero ohms, or battery voltage on both test points OL, or voltage on one test point only
Thermal fuse in a dryer, kettle or fan heater Appliance unplugged, continuity across the two leads Beep, near zero ohms OL
Plug fuse (UK style) Removed from plug, continuity Beep OL
Fuse in a powered low-voltage circuit DC or AC volts across the fuse with the load switched on Close to zero volts Roughly full supply voltage

The voltage-across method works because an intact fuse drops almost nothing. When the fuse is open and the load is connected, the whole supply voltage appears across the gap. If the load is switched off, though, there may be no voltage either way, so the result only counts with the load connected and switched on.

Testing a removed fuse in six steps

  1. Switch off and isolate the equipment. Unplug appliances, turn off the ignition and remove the key in a car, and for anything powered from a supply, turn it off before pulling the fuse.
  2. Remove the fuse with a fuse puller or insulated pliers. Note its rating and type printed on the cap or body so you can replace it like for like.
  3. Plug the black lead into COM and the red lead into the V-ohm jack, not the mA or 10 A jack. Select continuity, or the lowest ohms range on a manual-ranging meter.
  4. Touch the probe tips together first. You should hear a beep and see a small figure, usually a fraction of an ohm. That figure is the resistance of the leads, and you can subtract it from what you read next.
  5. Press one probe on each end cap or blade. Hold the fuse on a non-conductive surface rather than pinching both ends with your fingers, which can add a parallel path on high ohms ranges.
  6. Read the result. A beep or a near-zero reading means the fuse conducts. OL, a dash or no beep means the element is open and the fuse is blown.

A basic manual-ranging meter like the Klein Tools MM325 has the continuity and resistance functions you need, and its lead placement LEDs help you avoid testing with the red lead sitting in a current jack. If you want a voltage pen and outlet tester for checking whether power is present before you start, the KAIWEETS test kit bundles those with a meter.

Checking that the meter is telling the truth

A meter with a flat battery, a broken test lead or a blown internal fuse can make a good fuse look bad, or simply give confusing readings. Before you condemn a fuse, run two quick checks:

  • Short the leads together on continuity. No beep means the problem is the leads or the meter, not the fuse.
  • Test a fuse or a short piece of wire you know is good. If it reads near zero, the meter is fine and your original reading stands.

If readings jump or will not settle, the cause is usually poor contact on a dirty end cap or a tired lead. Clean the cap and press firmly; the article on why multimeter readings jump around covers the other common culprits.

One easy mistake: on the ohms setting, a meter connected across a fuse that is still in a circuit may read through the rest of the circuit. A blown fuse can then show a resistance instead of OL. Removing the fuse, or lifting one end, gives a clean answer.

When a fuse test turns into a safety job

A blown fuse is a symptom. Fuses open because something drew too much current: a shorted motor, a damaged cable, a failed component or a water leak. Replacing the fuse without finding the cause often means the new one blows straight away, and fitting a higher-rated fuse to stop that removes the protection the wiring depends on. Always use the same current rating, voltage rating and speed (fast-acting or time-delay).

Several situations are outside a meter test at home:

  • Cartridge fuses in a main switch, disconnect or service panel sit on circuits with very high fault energy. Testing or pulling them should be done by a licensed electrician with proper protective equipment and a meter rated for that location.
  • Microwave ovens contain a high-voltage capacitor that can hold a dangerous charge after unplugging. Leave fuse work inside them to someone trained to discharge it.
  • If a fuse in a plug or appliance blows repeatedly, or you smell burning or see scorch marks, stop using the appliance and have it inspected.

For home electrical tasks in general, choosing a multimeter for home electrical work explains which safety rating fits outlets and household circuits.

Test the fuse, then find out why it went

Pull the suspect fuse, short your leads to confirm the meter beeps, then put one probe on each end of the fuse. If it reads OL, replace it with the exact same rating and type, then check the device it protects for the fault that caused it before you switch back on.

Frequently Asked Questions

Can I test a fuse without removing it?

Yes, by measuring voltage across it with the circuit powered and the load switched on. Near zero volts means the fuse is intact, and full supply voltage across it means it is open. Only do this on low-voltage circuits or where you are trained and your meter is rated for the location.

What resistance should a good fuse have?

Most fuses read well under one ohm once you subtract the resistance of the test leads. Very small fuses rated in milliamps can read a few ohms because their element is so thin, and that is normal. Any open or OL reading means the fuse has blown.

Why does a blown fuse sometimes look fine?

The element can break right at the end cap or inside an opaque body where you cannot see it. Fuses can also fatigue and crack after repeated heating without visible damage. The meter test is the only reliable way to know.

Can I use the continuity beep on any meter?

Most digital meters beep below a threshold of a few tens of ohms, which is fine for fuses. If your meter has no beeper, use the lowest resistance range and look for a near-zero reading instead.

How do I test the fuse inside my multimeter?

Set the meter to ohms with the red lead in the V-ohm jack and touch the tip into the mA or 10 A jack. A low reading means that fuse is intact, and OL means it has blown and the current ranges will not work until it is replaced with the exact type in the manual.