Skip to content
AkerminMeasure. Monitor. Improve. Compare Products
Learning Center

Can I Use a Multimeter to Test AA Batteries?

You have a drawer of loose AA batteries and no idea which ones are still good. A multimeter sorts them in a few minutes, as long as you know what the numbers mean for each battery chemistry.

As an Amazon Associate, Akermin earns from qualifying purchases. Product links on this page are affiliate links.

Set the meter to DC volts, on the 2 V or 20 V range or auto, touch red to the battery’s positive end and black to the flat negative end, and read the voltage. A fresh alkaline AA reads around 1.5 to 1.6 volts; about 1.3 V is getting weak, and below roughly 1.2 V it is close to useless in most devices. Rechargeable NiMH cells read lower when full, around 1.3 to 1.4 V, so judge them on their own scale, and for a cell that reads fine but fails in use, test it under a light load.

What the voltage tells you, by battery type

A battery’s voltage at rest depends on its chemistry and on how much charge is left, but the relationship differs a lot between chemistries. That is the main reason people misread their test.

AA type Fresh or full Partly used Nearly flat
Alkaline About 1.55 to 1.65 V About 1.3 to 1.45 V Below about 1.2 V
Zinc carbon (heavy duty) About 1.5 to 1.6 V About 1.3 to 1.4 V Below about 1.2 V
NiMH rechargeable About 1.3 to 1.4 V just off charge About 1.2 to 1.25 V for most of its run Below about 1.1 V
Lithium iron disulfide (primary lithium AA) About 1.7 to 1.8 V Stays high for most of its life Drops quickly near the end
Rechargeable lithium AA with built in regulator Steady 1.5 V Steady 1.5 V Cuts out suddenly

Alkalines decline gradually, so their voltage is a reasonable fuel gauge. NiMH cells sit around 1.2 V for most of their discharge, and lithium types hold their voltage until they are nearly empty, so for those the meter tells you only good or dead, not how much is left.

Testing a cell, step by step

  1. Plug the black lead into COM and the red into the V socket. Never use the A or mA socket for this.
  2. Turn the dial to DC volts, the V with a straight line or a dashed and solid line above it. Pick 2 V or 20 V on a manual-ranging meter.
  3. Hold the battery by its middle. Touch the red probe to the raised positive end and the black probe to the flat negative end.
  4. Read the display. A minus sign just means the probes are reversed; the number is still valid.
  5. Compare with the table for that chemistry, and sort into good, weak and recycle piles.

Some meters, the Klein Tools MM325 among them, have a dedicated battery test function. Where the manual says that mode applies a small load while measuring, it gives a better answer than plain DC volts. If you are choosing a meter for this kind of job, how to choose a digital multimeter explains which functions are worth having.

Why a cell can read 1.4 V and still not work

A multimeter on voltage draws almost no current, a tiny fraction of a milliamp, so it measures the battery’s open-circuit voltage. An old alkaline can still show a respectable voltage with nothing connected, yet its internal resistance has risen so much that the voltage collapses as soon as a toy motor or a flash asks for current. That is the cell that reads fine and then fails in the device.

A load test exposes it. Connect a resistor across the battery and measure the voltage while the current flows. A 10 ohm resistor on a 1.5 V cell draws about 150 milliamps and dissipates about a quarter of a watt, so use a resistor rated at half a watt or more, and keep the test to a few seconds. A healthy alkaline should stay well above 1.2 V under that load; a cell that drops to 1 V or below has little useful capacity left. The simplest load test of all is to measure the battery while it sits in the device and the device is switched on, using the probes on the battery contacts.

A worked example makes the difference clear. Two used alkalines both read 1.42 V on the bench. On the 10 ohm load, the first falls to 1.31 V and holds there; the second falls to 1.05 V and keeps sinking. Using Ohm’s law, the first cell’s internal resistance is roughly (1.42 minus 1.31) divided by about 0.13 A, under one ohm, which is healthy. The second works out at several ohms, which is why it will die in a digital camera within minutes even though its resting voltage looked identical.

Mistakes that give wrong or dangerous results

  • Using the current range. Putting the probes across a battery with the meter on amps creates a short circuit through the meter. It can blow the meter’s fuse, heat the cell and, on larger batteries, cause sparks. Some people use a brief short-circuit current test as a quick strength check; it is hard on the battery and the meter, and a load resistor tells you the same thing more safely.
  • Low meter battery. A weak battery inside the meter can make every reading slightly off or jumpy. If numbers wander, see why multimeter readings jump around.
  • Testing straight off the charger. NiMH cells read high just after charging and settle after an hour or so.
  • Judging lithium cells by voltage alone. Their flat discharge curve means a nearly spent cell can look nearly new.
  • Ignoring physical signs. White crystals, a damp end, swelling or a dented case mean the cell is leaking or damaged. Do not test or reuse it; bag it and take it to a battery recycling point.

Checking your meter, and what to do with the results

If you are unsure your meter reads correctly, test a brand new alkaline straight from the pack. It should read a little above 1.5 V, typically 1.6 V or so. A reading far from that, from two or three fresh cells, suggests the meter or its battery needs attention.

Once sorted, weak alkalines still have uses in low drain devices such as wall clocks and remote controls, which run happily down to around 1.2 V. Keep good cells for high drain devices. Do not mix old and new cells, or different chemistries, in the same device, because the weaker cell can be driven into reverse and leak. Recharge only batteries marked rechargeable; attempting to charge an alkaline can cause leakage or rupture. If you need a meter that will also handle household electrical checks, the list of multimeters for home and DIY is a useful place to start.

Sort the drawer in five minutes

Empty the battery drawer onto the bench, set the meter to DC volts, and test every AA against the table for its type; keep anything above 1.45 V for cameras and toys, put the 1.2 to 1.45 V cells in clocks and remotes, and recycle the rest.

Frequently Asked Questions

What voltage is a dead AA battery?

Most devices stop working when an alkaline AA falls to roughly 1.0 to 1.1 V under load, which usually shows as below about 1.2 V on an open-circuit test. Rechargeable NiMH cells are considered empty around 1.0 to 1.1 V.

Can I test AAA, C and D batteries the same way?

Yes. They are all 1.5 V nominal cells with the same chemistry options, so the voltages in the table apply. Larger cells need a lower value or higher wattage resistor for a meaningful load test.

Why does my rechargeable AA read only 1.2 volts?

That is normal for NiMH. Their nominal voltage is 1.2 V, and they sit close to it for most of their discharge, so 1.2 V does not mean they are flat.

Is a battery tester better than a multimeter?

A dedicated tester applies a load, which makes it better at spotting weak cells than a plain voltage reading. A multimeter with a load resistor, or with a battery test mode, does the same job.

Can I test a 9V battery with the same setting?

Yes, on DC volts with the 20 V range. A fresh 9V alkaline reads around 9.5 V, and it is getting weak below roughly 8 V.