As an Amazon Associate, Akermin earns from qualifying purchases. Product links on this page are affiliate links.
A proper quantum PAR meter does measure PPFD; that is exactly what its number is. PAR is the band of light plants use, from 400 to 700 nanometres, and PPFD is how many photons in that band land on a square metre each second, shown in micromoles per square metre per second. Be careful with cheaper devices sold as PAR meters, because some are lux meters that estimate PPFD with a fixed conversion factor, which can be badly wrong under LED grow lights. Use a true quantum sensor, take readings at canopy height across the growing area, and multiply by your light hours to get the daily light integral.
PAR, PPF, PPFD and DLI: one quantity at four levels
These terms describe the same light at different points between the lamp and the leaf.
| Term | Meaning | Unit | Who uses it |
|---|---|---|---|
| PAR | The waveband plants use for photosynthesis, 400 to 700 nm | A range, not a quantity | Everyone, often loosely |
| PPF | Total photons in that band emitted by a lamp each second | micromoles per second | Lamp makers; measured in a sphere |
| PPFD | Photons in that band landing on one square metre each second | micromoles per square metre per second | Growers; read with a PAR meter |
| DLI | Total photons landing on one square metre over a whole day | moles per square metre per day | Growers planning light hours |
So a PAR meter, more precisely called a quantum sensor, measures PPFD. PPF is to PPFD what lumens are to lux: one describes the source, the other describes the light arriving at a surface.
How a quantum sensor counts photons
Photosynthesis responds roughly to the number of photons absorbed, not to how bright light looks to the human eye. A quantum sensor uses a photodiode behind filters chosen so that its response is as even as possible across 400 to 700 nm, and drops off sharply outside that band. Every photon in the band counts roughly equally, whether it is blue, green or red.
A lux meter does the opposite. It is filtered to match the human eye, which is most sensitive to green and much less to deep red and blue, exactly the colours many grow lights emphasise. That is why a red and blue LED fixture can show a modest lux reading while delivering a high PPFD. The page on lux meters versus PAR meters covers this in depth.
Some instruments, often sold as PAR meters at low cost, contain a lux sensor and multiply by a conversion factor. For sunlight, a common rule of thumb is roughly 54 lux per micromole per square metre per second, but the factor changes with every light spectrum. Unless the device states that it uses a quantum sensor, assume its PPFD figure is an estimate. A dedicated sensor such as the Quantum PAR meter, which specifies the 400 to 700 nm band, measures PPFD directly.
A useful sense check is to take the meter outside. Direct midday sun in summer is commonly quoted at around 2,000 micromoles per square metre per second at the ground, an overcast day gives a small fraction of that, and a bright indoor room away from windows gives only a few tens at most. If your meter reads in those rough proportions outdoors and under a cloud, its scale is at least plausible. If it reads the same indoors and outdoors, or gives a full sun figure under a desk lamp, it is not measuring PPFD in any meaningful way, and its numbers should not guide your lighting.
Measuring PPFD across a grow area
- Turn off other lights and let the grow light warm up. LED output stabilises after some minutes. Measure in the conditions your plants actually see.
- Hold the sensor level at canopy height. Readings change quickly with distance from the lamp, so measure at the top of the plants, not at the pot rim.
- Keep your hands and body out of the light path. Use a sensor on a cable or stand where possible.
- Take a grid of readings. For a small tent, a grid of nine points, centre, edges and corners, gives a good picture. Write each value down.
- Calculate the average and look at the spread. The centre is usually brightest. Corners under a single lamp can be half the centre value or less.
- Adjust lamp height or position. Raising a lamp spreads light more evenly and lowers PPFD at the centre; lowering it concentrates light. Re-measure after each change.
Turning PPFD into daily light integral
PPFD is a rate. Plants respond to the total amount delivered over the day, the DLI. The conversion is straightforward:
DLI = PPFD x hours of light x 0.0036
The factor 0.0036 comes from 3,600 seconds per hour divided by 1,000,000 micromoles per mole.
Worked example. Your average PPFD at canopy height is 450 micromoles per square metre per second, and the light runs 16 hours a day. DLI equals 450 x 16 x 0.0036, which is 25.9 moles per square metre per day. If you shorten the photoperiod to 12 hours for flowering, DLI drops to 450 x 12 x 0.0036, which is 19.4. To keep the same DLI at 12 hours, PPFD would need to rise to about 600.
Different plants have very different needs. Leafy greens and seedlings generally do well with lower DLI, while fruiting crops typically want more. Use crop specific guidance from a reputable horticultural source for targets, and use the meter to check you are delivering them. For a broader comparison of instruments for growers, see choosing between a lux meter and a PAR meter for plants.
Errors that make PPFD readings wrong
- A lux sensor with a conversion factor. Under purple or red heavy LEDs the estimate can be off by a large margin.
- Poor spectral response at the edges. Inexpensive quantum sensors may under read deep red or blue. If your fixture has strong peaks near the ends of the band, results may read low.
- Far red light. Many modern fixtures include far red, beyond 700 nm. A standard PAR sensor ignores it by design; extended range sensors that include it report a different figure, sometimes called ePAR.
- Tilted sensor. A sensor not held level reads less light from overhead sources.
- Dirty diffuser. Dust, nutrient spray and fingerprints on the sensor head reduce readings. Wipe it gently with a soft cloth.
- Calibration drift. Sensors age. Compare with a second meter occasionally, and follow the maker’s recalibration advice.
If you want to compare current models, see our PAR meter picks.
Map your canopy this week
Raise the sensor to canopy height, take a nine point grid with the light on and the room otherwise dark, and write down the average PPFD. Multiply that average by your light hours and 0.0036 to get the DLI, then adjust lamp height or hours until it matches the target for your crop.
Frequently Asked Questions
Is PAR the same as PPFD?
Not exactly. PAR is the 400 to 700 nm band of light, while PPFD is the measured number of photons in that band arriving on a square metre every second.
Can I convert lux to PPFD?
Only approximately, using a factor that depends on the light spectrum. For sunlight a rough figure is about 54 lux per unit of PPFD, but LED grow lights can differ a lot, so a quantum sensor is more reliable.
Why does my PAR meter read differently from the lamp's PPFD chart?
Manufacturer charts are usually measured at specific heights in a reflective tent with the lamp fully warmed up. Differences in height, wall reflectivity, sensor quality and lamp settings all change the reading.
Does a phone app measure PPFD?
A phone light sensor is designed to match the human eye, like a lux meter, so any PPFD figure is a conversion estimate. Some apps support an add on diffuser, but a dedicated quantum sensor is still more trustworthy.
What PPFD is too much for plants?