END on the display of a First Alert carbon monoxide alarm is its end-of-life message: the built-in timer has reached the rated life of the electrochemical CO sensor, and the alarm can no longer be relied on to measure carbon monoxide. It will usually chirp at a regular interval as well. A new battery or a reset will not clear it, so replace the alarm as soon as possible and put a working CO alarm in its place the same day, especially near bedrooms and fuel-burning appliances.
Why a CO sensor has a fixed lifespan
Most home carbon monoxide alarms, including First Alert’s digital models, use an electrochemical sensor. Inside is a small cell with electrodes and an electrolyte. When CO molecules diffuse in, they are oxidised at one electrode, producing a tiny current proportional to the concentration. The alarm’s circuit converts that current to parts per million and decides when to sound.
The cell does not last forever. Its electrolyte slowly dries, the catalyst on the electrode loses activity, and exposure to solvents, cleaning products or very high humidity can age it faster. As it ages, the same CO concentration produces a smaller current, so the alarm reads low. Because there is no way for a homeowner to calibrate the cell against a known gas, manufacturers set a fixed service life and program the alarm to retire itself. Depending on the model that life is commonly seven or ten years from the date the alarm is powered up or manufactured, as stated on its label.
When the counter expires, the display shows END and the alarm chirps. The rest of the electronics are fine; it is the measurement you can no longer trust.
END compared with the other First Alert codes
| Display or sound | What it usually means | What to do |
|---|---|---|
| END, regular chirp | Sensor end of life | Replace the alarm |
| ERR or Err, chirp pattern | Self-test found a fault | Reset once; replace if it returns |
| LB or low-battery chirp | Battery or backup battery weak | Fit a fresh battery of the type on the label |
| A number in ppm | CO reading above the display threshold | Ventilate and investigate; if alarming, leave |
| Four beeps then a pause, repeated | CO alarm | Get everyone out and call for help |
| Peak value shown after a button press | Highest CO level stored since last reset | Note it for the gas engineer |
Some First Alert models let you silence the end-of-life chirp for a limited time with the button, so you can get a replacement without listening to it all night. That silence is temporary, and the alarm is still not protecting you during it.
Replacing the alarm without a gap in protection
- Confirm it is END, not a reading. Look at the display in good light. If you see a number or hear four beeps and a pause, treat it as a CO alarm, not end of life.
- Check the label. Note the model and manufacture date. If the alarm is far younger than its rated life, contact First Alert about warranty, as an early END could indicate a fault.
- Get a replacement for the same location. A plug-in alarm needs an outlet that is not switched or behind furniture; a battery model can go on a wall or shelf; hardwired units need a compatible harness.
- Fit the new alarm following its manual. CO mixes fairly evenly with room air, so manufacturers give a range of acceptable heights; follow the one in the instructions.
- Press test and confirm the alarm sounds and the display goes through its self-check.
- Write the install date on the new alarm and set a reminder for its replacement year.
- Dispose of the old unit according to local rules for electronics and batteries.
A plug-in digital model such as the First Alert plug-in CO alarm with digital display has battery backup and a peak-level memory according to its listing, which helps when you need to tell an engineer what level was reached. The First Alert plug-in carbon monoxide alarm review goes into it in more detail, and the Kidde 3rd Edition review covers a comparable plug-in alternative.
Checking the new alarm responds to CO
The test button checks the horn and circuit, not the sensor’s response to gas. A home user cannot safely produce a known CO concentration, and you should never use car exhaust or a smouldering fire to test an alarm. There are two practical ways to gain confidence instead.
- Canned test gas. Professional CO test gas and a hood are used by heating technicians to bump-test alarms. If you have an annual boiler or furnace service, ask the engineer to check your alarm.
- A second instrument. A handheld CO meter such as the Klein Tools ET110 CO meter lets you spot-check near appliances and compare readings when an alarm reports a low number. In clean indoor air both should read zero or close to it.
Alarms built to the main home standards are designed not to alarm at very low CO levels for short periods, so they will not show the small rises a low-level monitor can display. If someone in the home is especially vulnerable, a monitor that shows low concentrations, such as the Fast Low Level CO Monitor, adds visibility below the alarm thresholds.
If the old alarm had been showing readings
Before you throw away the old alarm, press the peak or menu button if it has one and note the highest reading stored. A non-zero peak shows that CO was present at some point, which is worth investigating even though the sensor has now retired.
Carbon monoxide comes from incomplete combustion. The usual home sources are gas or oil boilers and furnaces, water heaters, gas cookers, fireplaces and wood stoves, and engines running in or near the building, including generators and cars in attached garages. Signs of a problem include soot staining around appliances, a yellow or floppy gas flame instead of a crisp blue one, and condensation on windows near a heater.
If anyone has headaches, dizziness, nausea or confusion that improve when they leave the house, or if any CO alarm sounds its emergency pattern, leave immediately, call emergency services or your gas utility from outside, and do not go back in until the building is declared safe. Have fuel-burning appliances checked by a qualified, licensed gas engineer or heating technician.
Replace it today, then check the peak
Unplug or take down the alarm showing END, read its peak value and label date, and fit a new CO alarm in the same spot before tonight. Then book a service for any boiler, furnace or water heater that has not been checked recently, and mention the old alarm’s peak reading to the engineer.
Frequently Asked Questions
Can I reset END on a First Alert CO alarm?
No. END is triggered by the alarm's life timer, and resetting or changing the battery does not restart it. The only fix is a new alarm.
How long do First Alert CO alarms last?
It depends on the model; the rated life is printed on the label and in the manual, commonly seven or ten years. The END display appears when that period has passed.
Is it safe to keep using the alarm for a few days after END appears?
Treat it as not protecting you. The sensor may still respond, but its accuracy is no longer guaranteed. Replace it as soon as possible and use a working alarm in the meantime.
Why did my alarm show END much earlier than expected?
Exposure to solvents, cleaning sprays, extreme humidity or heat can shorten sensor life, and some alarms count from manufacture rather than installation. If it is well within its rated life, contact the manufacturer about warranty.
Do I need to replace my smoke alarms at the same time?
Only if they are also at end of life. Combination smoke and CO alarms retire both functions together, but separate smoke alarms have their own date on the label.