Skip to content
AkerminMeasure. Monitor. Improve. Compare Products
Learning Center

How Do I Know If My Multimeter Can Test Capacitors?

You have a suspect capacitor from an air conditioner, a power supply or a ceiling fan, and you are not sure the meter in your toolbox can check it. A quick look at the dial and the manual answers that.

As an Amazon Associate, Akermin earns from qualifying purchases. Product links on this page are affiliate links.

Look at the selector dial for a capacitance position: the symbol is two short parallel lines, one sometimes curved, or the letters F, nF, uF or CAP, and on some meters it shares a position with ohms or diode and is reached with a function button. If it is there, check the manual for the maximum capacitance, because many meters stop at a few hundred microfarads while others go far higher. A meter with no capacitance mode can still give a rough good or bad check on larger capacitors with the ohms range, but it cannot tell you the value.

Reading your dial and spec sheet

Capacitance is measured in farads, but the useful units for real parts are much smaller: picofarads (pF), nanofarads (nF) and microfarads (uF, sometimes written with the Greek mu or as MFD on motor capacitors). Meters label the function in a few ways.

What you see on the meter What it means
Capacitor symbol, two parallel lines, at its own dial position Dedicated capacitance mode
F, nF or uF printed near ohms, with a SELECT or FUNC button Capacitance shares a dial position; press the button until F appears on the display
A row of fixed ranges such as 2n, 20n, 200n, 2u, 20u Manual-ranging capacitance; pick the range just above the expected value
Input sockets labelled Cx or a small slot on the front Capacitance socket for leaded parts on older or budget meters
Only V, A, ohms, continuity and diode No capacitance function; use the ohms workaround or a dedicated tester

The manual’s specification table tells you the highest value it measures and its accuracy, often a few percent. If your meter’s spec stops at 100 or 200 uF and you need to check a large electrolytic, it will read overload. Pocket meters such as the ALLOSUN pocket multimeter list capacitance among their functions; others leave it out entirely, so the dial is the quickest check. If you are comparing models for this, how to choose a digital multimeter walks through which functions matter.

How the meter measures a capacitor

In capacitance mode the meter pushes a small known current into the capacitor and times how quickly the voltage across it rises, or it charges and discharges it repeatedly and measures the cycle. A bigger capacitor takes longer to charge, so the meter can calculate its value. That is why a large capacitor can take several seconds to give a reading, and why the display may count up before it settles.

Two consequences follow. The capacitor must be fully discharged first, or the stored charge confuses the timing and can damage the meter. And the part should be out of the circuit, or at least have one leg lifted, because other components in parallel change the charging time and the result.

Testing a capacitor, step by step

  1. Switch off and isolate the equipment. For an air conditioner or heat pump, turn off the disconnect and the breaker; for electronics, unplug it and wait.
  2. Discharge the capacitor. Use a resistor in the kilohm range, rated for a few watts, with insulated leads across the terminals for several seconds, then confirm with the meter on DC volts that it reads close to zero. Do not short large capacitors with a screwdriver; the spark can pit the terminals and throw molten metal.
  3. Note the rated value and tolerance printed on the case, for example 45 plus 5 uF with a tolerance of a few percent on a dual run capacitor.
  4. Remove at least one lead from the capacitor and label wires before you pull them.
  5. Set the meter to capacitance and connect the probes. Polarity matters only for electrolytic capacitors; put red on the positive lead.
  6. Wait for the reading to settle and compare it with the rating. On a dual run capacitor, measure between C and HERM, then between C and FAN.
  7. Look at the case too. A bulging top, leaking oil or electrolyte, or a cracked casing means replace it whatever the meter says.

No capacitance mode? The ohms workaround

With the capacitor discharged and disconnected, set the meter to a high ohms range and touch the probes to its leads. The meter’s test current starts to charge it, so a healthy capacitor shows a low resistance that climbs steadily toward overload. Reverse the probes after discharging again and you should see the same climb. A reading that stays near zero means the capacitor is shorted; an instant overload with no climb on a large capacitor means it is open. This only works on values large enough to watch, roughly the microfarad range and above, and it tells you nothing about the actual value. An analog meter shows the effect more clearly because the needle swings up and slowly falls back.

When the meter says good but the capacitor is not

A multimeter measures capacitance at a low voltage and a single low frequency. It does not measure equivalent series resistance (ESR), which is the internal resistance that rises as electrolytic capacitors age and dry out. A power supply capacitor can show the correct microfarads and still be the reason the supply fails, because its ESR has climbed. If you repair electronics, an ESR meter or a component tester is the better instrument for electrolytics. Likewise, a motor run capacitor can test close to its rating cold and fail under heat and full voltage; if the motor hums, starts slowly or trips on overload, replacement is a reasonable next step even with a marginal reading.

Typical tolerances: motor run capacitors are usually rated within a few percent, while general electrolytics are often plus or minus twenty percent. A reading outside the printed tolerance means replace it. Readings that drift or jump while you watch often come from poor probe contact or residual charge; why multimeter readings jump around covers the usual culprits.

Safety boundaries

Capacitors hold charge after power is removed, sometimes for a long time. Air conditioner capacitors sit beside mains-voltage contactors, and some equipment, such as microwave ovens and older televisions, contains capacitors charged to lethal voltages. Do not attempt those unless you are trained. For HVAC work, if you are not confident isolating the unit and verifying it is dead, call a licensed technician. Make sure the meter carries an appropriate CAT rating for the voltage checks around the job.

Check the dial, then the manual

Turn your meter’s dial slowly and look for the capacitor symbol or the letter F; if you find it, look up the top of its capacitance range in the manual before you pull the part, so you know the reading you get is one the meter can actually make.

Frequently Asked Questions

Why does my meter show OL in capacitance mode?

Either the capacitor is larger than the meter's maximum range, the range selected is too low on a manual meter, or the capacitor is shorted. Try a higher range, then check resistance across the discharged part to rule out a short.

Can I test a capacitor without removing it?

Sometimes, but the result is unreliable because resistors and other parts in parallel change the reading. On a simple HVAC circuit, disconnecting the wires from the capacitor terminals is enough; on a circuit board, lift one leg.

What does MFD mean on a capacitor?

MFD is an older way of writing microfarads, the same as uF. A capacitor marked 5 MFD should read about 5 uF on the meter.

Do I need a true RMS meter to test capacitors?

No. True RMS affects how a meter reads AC voltage and current with distorted waveforms. It has nothing to do with the capacitance function.

How long should a capacitance reading take?

Small values settle almost instantly. Large electrolytics can take several seconds or more because the meter has to charge them, so wait until the number stops changing.