As an Amazon Associate, Akermin earns from qualifying purchases. Product links on this page are affiliate links.
Look first for the radon result and its unit, either picocuries per litre (pCi/L) or becquerels per cubic metre (Bq/m³); 1 pCi/L equals 37 Bq/m³. Then check the test type and length, where in the house it was measured, and whether the report confirms closed-house conditions, because these decide how much the number can be trusted. For continuous monitor reports, use the average over the whole test, not the hourly peaks. A result at or above 4 pCi/L, about 148 Bq/m³, means follow-up testing or mitigation under US EPA guidance, and many agencies recommend acting from lower levels.
The parts of a typical report
| Section | What it tells you | What to check |
|---|---|---|
| Result | Average radon concentration over the test | Unit: pCi/L or Bq/m³ |
| Test type | Charcoal, alpha track, electret, or continuous monitor | Short-term or long-term |
| Test period | Start and end times and total hours or days | At least 48 hours for a short-term test |
| Location | Room and floor tested | Lowest lived-in level, not kitchen or bathroom |
| Conditions | Closed-house statement, weather notes | Windows closed 12 hours before and during short tests |
| Device and lab data | Serial number, calibration date, lab ID | Matches the device you used |
| Uncertainty or error | Range around the result | Wider for low results and short tests |
| Quality control | Duplicates, blanks, tamper flags | No flags or explained ones |
A lab report for a kit you placed yourself is usually one page with the result and a few lines of conditions. A professional continuous monitor report for a home sale is longer, with an hourly graph, temperature, humidity, pressure and tamper indicators.
Understanding the number
The result is an average concentration over the test period. Converting between units is simple: multiply pCi/L by 37 to get Bq/m³, or divide Bq/m³ by 37 to get pCi/L. So 2.7 pCi/L is about 100 Bq/m³, the WHO reference level, and 4.0 pCi/L is about 148 Bq/m³, the US EPA action level.
- Below 2 pCi/L (74 Bq/m³): low; retest after major changes to the house or heating, or every few years.
- 2 to 4 pCi/L (74 to 148 Bq/m³): the EPA suggests considering mitigation; in countries using 100 Bq/m³, the upper part of this band is already above the reference level.
- 4 pCi/L and above: follow-up testing and, if confirmed, mitigation.
Some results are reported as “less than” a value, for example <0.5 pCi/L. That means the level was below what the method can reliably detect, which is a good result.
Uncertainty appears as a plus or minus figure. A result of 3.6 plus or minus 0.6 pCi/L means the true average likely lies between 3.0 and 4.2, so it straddles the action level. Treat results near the line with a follow-up test rather than as a firm yes or no.
A worked example puts this together. A report shows 5.2 pCi/L from a three-day charcoal test in a finished basement, with closed-house conditions confirmed. Converted, that is about 192 Bq/m³, above both the EPA action level and the WHO reference level. The right next step is a follow-up test, not immediate panic and not a shrug. If a second short test averages with the first above 4 pCi/L, or a long-term test confirms it, the house needs mitigation. If the same report had shown 1.1 pCi/L, about 41 Bq/m³, a retest in winter would be all you need to plan.
Continuous monitor reports and hourly graphs
Professional continuous radon monitors log every hour. Reports show the hourly values on a graph, plus the overall average. The average is the result; individual hours often swing well above and below it as weather, heating and ventilation change. A peak of 9 pCi/L at four in the morning in a house averaging 3 pCi/L is normal behaviour, not a separate problem.
Read the graph for shape. A steady daily rhythm, higher at night and early morning, is typical. A sudden sustained drop part way through can mean a window was opened or the device moved; good monitors flag motion and power interruptions, and testers often discard the first few hours while the device equilibrates. The report should say how the average was calculated and whether any hours were excluded. How these monitors are used in property deals is covered in radon monitors for real estate inspections.
If you are reading your own consumer monitor, such as the RM-60 portable radon detector, the same logic applies: use the long-run average shown in its history view, not the current hourly figure, and allow several days before drawing conclusions.
Short-term, long-term and duplicate results
A short-term test covers two to ninety days, most often two to seven. A long-term test runs ninety days or more and gives a better estimate of the yearly average that drives health risk. The differences are explained in short-term versus long-term radon readings.
EPA guidance for homeowners runs roughly like this:
- If a first short-term test is below 4 pCi/L, retesting later is optional but useful, especially in a different season.
- If it is 4 pCi/L or higher, do a follow-up test. A long-term follow-up gives the better estimate; a second short-term test gives a quicker answer, and the higher the first result, the stronger the case for the quicker route.
- If a long-term follow-up is 4 or higher, or the average of two short-term tests is 4 or higher, fix the house.
Some reports show two side-by-side devices, called duplicates. Average them. If they differ a lot from each other, the report should note it, and a retest may be needed. Real estate tests are usually short-term because of timing, so a buyer may want a long-term test after moving in.
Red flags and what to do next
Question a report if the test lasted less than 48 hours, the location was a kitchen, bathroom, laundry or crawl space, closed-house conditions were not followed or not stated, the device serial number does not match, the lab received a kit late, or tamper flags are unexplained. Ask the lab or tester; reputable ones will explain or offer a retest.
If your confirmed result is high, contact a certified or licensed radon mitigation contractor where your country or state has a scheme. A sub-slab depressurisation system usually reduces levels substantially, and a test after installation confirms it worked. Radon is a long-term risk, not an emergency requiring you to leave home, but a confirmed high result should not be left for years. For background on why ongoing monitoring helps after mitigation, see what radon is and why long-term monitoring matters.
Circle three things on your report
Mark the result with its unit, the test length and the room tested. If the result is 4 pCi/L or more, or within its uncertainty of that line, book a follow-up test this week; if it is clearly low and the test was done properly, file the report and plan a retest after any major renovation.
Frequently Asked Questions
What is a normal radon level in a house?
Typical indoor averages in many countries are around 1 to 2 pCi/L, but individual homes vary widely. Outdoor air is usually much lower, often below 0.5 pCi/L.
My report shows a high peak but a low average. Should I worry?
The average is what matters for risk and for decisions. Hourly peaks are normal and reflect weather and ventilation changes.
Why did two tests in the same house give different results?
Radon varies with weather, season, heating and ventilation, and with the room tested. Differences of 20 to 30 percent between short tests are common.
Can a seller's radon test report be trusted?
It can, if done by a certified tester following closed-house protocol with tamper detection. Check the dates, location and conditions, and retest if anything looks off.
What unit should my radon report use?
The US uses pCi/L, and most other countries use Bq/m³. Both describe the same thing; multiply pCi/L by 37 to convert.