Skip to content
AkerminMeasure. Monitor. Improve. Compare Products
Editorial desk

Environmental Monitoring Desk

Editorial desk

The Akermin Environmental Monitoring Desk researches hygrometers, weather stations, data loggers, sound and light meters. Every guide is written from manufacturer documentation, datasheets and published standards; Akermin does not run a test laboratory and never claims hands-on testing.

Areas of specialisation

hygrometers · weather stations · data loggers · sound and light meters

Covers

Environmental Monitoring

Guides

NDIR

How Accurate Is the Seneye PAR Meter?

The Seneye light reading is a good relative indicator at the device's own position, but its absolute PAR depends on calibration to the light spectrum and should be cross-checked with a quantum sensor before big changes.

Read More→
NDIR

How Accurate Is an EMF Detector?

A typical consumer EMF meter is good enough to locate sources and compare levels, but its absolute reading can be off by a wide margin depending on field type, frequency, axis count and how it is held.

Read More→
NDIR

How Accurate Is a Sling Psychrometer?

A sling psychrometer can be accurate to within a few percent relative humidity when used carefully, but small wet bulb errors from a dirty or dry wick, too little spinning or slow reading become large humidity errors, especially in cold or dry air.

Read More→
NDIR

How Accurate Is a K Type Thermocouple?

Standard type K thermocouple wire is accurate to about plus or minus 2.2 °C or 0.75 percent of reading, whichever is larger, with special-limits wire about twice as good, before adding instrument and installation errors.

Read More→
NDIR

How Accurate Is a Davis Cup Anemometer?

A Davis cup anemometer is accurate enough for weather monitoring when new and well sited, but mounting height, nearby obstacles, gust behaviour and bearing wear usually cause far larger differences than the sensor specification.

Read More→
NDIR

How Accurate Is a Barometric Altimeter?

A barometric altimeter is very sensitive to height changes over minutes, but because weather changes air pressure, its absolute altitude can drift by tens of metres within hours unless you recalibrate at a known elevation.

Read More→
NDIR

How Accurate Are Lux Meter Apps?

Lux meter apps are useful for comparing brighter and darker spots, but phone ambient light sensors are not designed as measuring instruments, so absolute readings can be off by tens of percent or more unless calibrated against a real meter.

Read More→
NDIR

How Accurate Are Humidity Sensors?

Consumer humidity sensors are typically accurate to plus or minus 2 to 5 percent relative humidity in the middle of their range, with larger error near very dry or very wet conditions and slow drift over time.

Read More→
NDIR

How a Differential Pressure Gauge Works

A differential pressure gauge has a high and a low pressure port feeding opposite sides of a diaphragm or sensor, so it displays only the difference between the two, which is how filter loading, duct pressure and gas pressures are checked.

Read More→