Used correctly, a sling psychrometer typically gives relative humidity within a few percent, which is comparable to a good digital hygrometer. Its accuracy depends almost entirely on technique: the wet bulb wick must be clean and wet with distilled water, the instrument must be spun long enough for the wet bulb to reach its lowest temperature, and the thermometers must be read quickly and precisely. A wet bulb error of just half a degree Fahrenheit can shift the result by about two percentage points of humidity at room conditions, and more in cold or dry air. Below freezing, or in very dry air, its accuracy falls off and a calibrated electronic instrument is the better choice.
Why small temperature errors become big humidity errors
A sling psychrometer has two thermometers mounted side by side on a handle that you whirl through the air. One reads the dry bulb, ordinary air temperature. The other has a cotton wick soaked in water. As you spin it, water evaporates from the wick and cools it to the wet bulb temperature. The drier the air, the faster the evaporation and the lower the wet bulb reads.
Humidity is calculated from the difference between the two, the wet bulb depression, using a chart or slide rule. The key point is that the whole answer comes from a difference of a few degrees, so any error in either thermometer is a large share of that difference.
Worked example. Dry bulb 75 degrees F, wet bulb 65 degrees F, at sea level pressure. The depression is 10 degrees and the relative humidity is about 58 percent. If the wet bulb was actually read half a degree low, at 64.5 degrees, the calculated humidity drops to about 56 percent. If the wick was partly dry and read 66 degrees, the result rises to around 62 percent. A one degree wet bulb error has moved the answer by roughly four to five points.
Our step by step guide to using a psychrometer covers technique in full; the rest of this page focuses on what limits accuracy.
The main sources of error
| Error | Effect on humidity | How to avoid it |
|---|---|---|
| Wick dry or not fully wet | Reads too high | Soak thoroughly before every reading; refill reservoir |
| Dirty or mineral crusted wick | Reads too high | Replace the wick regularly; use distilled water only |
| Not spinning long enough | Reads too high | Spin, read, and repeat until the wet bulb stops falling |
| Reading too slowly after spinning | Reads too high, as the wet bulb warms | Read the wet bulb first, within seconds |
| Thermometers disagree when dry | Offset in every reading | Compare both dry before wetting; correct or replace |
| Body heat or breath near the bulbs | Unpredictable | Hold at arm’s length and do not breathe on it |
| Parallax when reading scales | Small but adds up | Read at eye level, square to the scale |
| Altitude not accounted for | Small error at high altitude | Use a chart or calculator corrected for barometric pressure |
| Air below freezing | Large and uncertain | Use an electronic sensor instead |
Notice that most errors make the reading too high. That is because nearly every mistake keeps the wet bulb warmer than it should be, which shrinks the depression and looks like moist air.
Getting the most accurate reading
- Check the thermometers dry. Before wetting the wick, spin the psychrometer and compare both readings. They should agree within the scale’s smallest division. Note any difference and correct for it.
- Wet the wick with distilled water. Tap water leaves minerals that slow evaporation over time. The wick should be saturated but not dripping.
- Spin at a steady pace in the air you want to measure. Stand away from heat sources, sunlight, and air from supply registers unless that is what you are measuring.
- Spin for the time the instructions recommend, then read the wet bulb. Read it immediately, before the dry bulb.
- Spin again and re-read. Repeat until two successive wet bulb readings agree. The lowest stable value is the correct wet bulb.
- Look up humidity and dew point. Use the instrument’s slide rule, a psychrometric chart or the method in calculating dew point from temperature and humidity.
A digital alternative removes most technique errors. A ERAY digital psychrometer reads temperature and humidity electronically and calculates wet bulb and dew point, while the YT606 wet bulb meter offers wet bulb as one of its display modes. These depend instead on the humidity sensor staying calibrated.
Checking a psychrometer against a reference
You can verify both types of instrument.
- Ice point check for the thermometers. Put both thermometer bulbs into a well stirred slurry of crushed ice and a little water. Both should read 32 degrees F or 0 degrees C. Any difference is an offset to apply.
- Side by side with a calibrated hygrometer. Measure in still, steady room air next to an instrument with a recent calibration. Take several sling readings and average them.
- Salt test for digital types. A saturated salt slurry in a sealed container holds the air at about 75 percent relative humidity. The method is explained in how to calibrate a hygrometer.
If thermometers fail the ice point check by more than their scale resolution, or a glass thermometer has a break in its liquid column, replace it. Do not try to repair a broken liquid in glass thermometer; if it contains mercury, follow local guidance for safe cleanup and disposal.
When a sling psychrometer is the wrong choice
The method works best between cool and warm room conditions and moderate humidity. It struggles in three situations:
- Below freezing, where the wick may be ice or supercooled water, and the charts differ.
- Very dry air, where the wet bulb depression is large and small errors still matter, and the wick dries out quickly.
- Small or enclosed spaces such as wall cavities, ducts or cabinets, where there is no room to spin the instrument.
For continuous monitoring, logging or these awkward cases, a calibrated electronic hygrometer is more practical. The dew point explainer covers why the value you calculate matters for condensation and mould risk.
Check it dry, then spin until it settles
Before your next reading, spin the psychrometer with a dry wick and confirm both thermometers agree, then soak the wick in distilled water and spin and read the wet bulb repeatedly until two readings match. Use that lowest stable value for the humidity calculation, and if the air is below freezing, switch to an electronic hygrometer instead.
Frequently Asked Questions
Is a sling psychrometer more accurate than a digital hygrometer?
With good technique, it can match a good digital hygrometer, and it does not drift the way electronic sensors can. In practice, technique errors make many sling readings less reliable than a well calibrated digital meter.
How long should I spin a sling psychrometer?
Follow the instrument's instructions, then keep spinning and reading until the wet bulb stops falling. Two consecutive equal wet bulb readings mean you have reached the true value.
Why is my sling psychrometer reading high humidity?
The most common cause is a wet bulb that is warmer than it should be, from a dry or dirty wick, too little spinning or reading too slowly. Rewet the wick with distilled water and repeat the readings.
Can I use tap water on the psychrometer wick?
It works short term, but minerals build up in the wick and slow evaporation, which makes readings too high over time. Distilled water keeps the wick working properly.
Does altitude affect sling psychrometer readings?
The thermometer readings are not affected, but the humidity calculated from them depends slightly on barometric pressure. At high altitude, use a chart or calculator that accounts for your pressure.