Skip to content
AkerminMeasure. Monitor. Improve. Compare Products
Learning Center

How to Factory Reset a FLIR Camera

Your FLIR thermal camera is freezing, showing strange temperatures or carrying settings someone else changed, and you want it back to how it left the factory. Before you wipe it, it pays to know which kind of reset you actually need.

As an Amazon Associate, Akermin earns from qualifying purchases. Product links on this page are affiliate links.

On most FLIR handheld cameras, such as the E-series, the reset lives in the settings menu under device settings, where you can choose between restoring camera mode defaults, restoring all settings to factory default, or restarting the camera. Phone attachments like the FLIR One have no menu of their own, so you reset them by clearing or reinstalling the app and power-cycling the device. Copy your images off first, and try a simple restart before any full reset, because many freezes and odd readings clear without wiping anything.

Three levels of reset, and which one fixes what

People say “factory reset” for three quite different actions, and choosing the lightest one that works saves you from rebuilding your settings.

Reset type What it does What survives Use it when
Forced restart Powers the processor off and back on Everything Frozen screen, unresponsive buttons, Wi-Fi stuck
Camera mode or settings reset Returns emissivity, palette, span, units and measurement tools to defaults Images, date and language usually kept Readings look wrong after someone changed parameters
Full factory default Restores every user setting to how it shipped Calibration data stays in protected memory; images may or may not be kept depending on model Handing the camera on, persistent glitches, unknown history

A factory reset never changes the radiometric calibration. That is stored separately and can only be redone by a service centre with blackbody references. If your camera reads a known surface badly wrong even after a full reset, the reset was not the answer, and the later sections explain what to check instead.

Before you reset: save and note

  1. Back up images. Connect by USB or remove the SD card if the model uses one, and copy the image folder to a computer. Radiometric JPEGs carry the temperature data, so keep the originals, not screenshots.
  2. Write down custom settings. Emissivity values you use for common materials, reflected temperature, any custom alarms and Wi-Fi pairing details are all lost in a full reset.
  3. Charge the battery. A reset or firmware update that is interrupted by a flat battery can leave the camera in a worse state.
  4. Check the firmware version. Note it from the camera information page. Many known bugs are fixed by an update, which can be a better cure than a reset.

Where the reset is on common FLIR models

Menu names vary between firmware versions, so treat these paths as a guide and look for the closest wording on your screen.

  • E-series handhelds such as the FLIR E6 Pro and older Exx models. Open the main menu, go to Settings, then Device settings, then Reset options. You normally see choices to reset the default camera mode, reset device settings to factory default, and restart the camera. Pick the factory default option and confirm. The camera restarts by itself.
  • Spot-style imagers such as the TG series. These have a simpler menu. The reset, where present, is usually in the settings or system area at the bottom of the list, sometimes labelled factory reset or restore defaults.
  • FLIR One and other phone attachments. The camera holds very little configuration. Force close the FLIR app, clear its cache or reinstall it, charge the attachment fully, then reconnect. Depending on the app version, its settings screen may also offer a way to reset preferences.
  • Professional T-series and fixed cameras. These often add a reset in the camera web interface or desktop software, and fixed automation cameras may need a physical reset procedure from the manual because they sit on a network.

If the screen is frozen and you cannot reach any menu, hold the power button down for considerably longer than a normal press. On many handhelds a long hold forces a hard shutdown. Wait a few seconds and switch on again. If even that fails, removing and refitting the battery, on models with a removable pack, does the same job.

Checking readings after the reset

After a reset the camera returns to its default emissivity, usually a high value close to 0.95, and default reflected temperature. That is right for skin, painted walls, wood and most building materials, but wrong for bare metal. The theory is explained in what emissivity is in thermal imaging, and shiny surfaces have their own pitfalls covered in why shiny metal can mislead a thermal camera.

A quick sanity check needs no special kit:

  • Point the camera at a glass of iced water stirred well, with a piece of matt black tape or paper on the outside wall of the glass. After a minute the tape should read close to 0 C, within the camera’s stated tolerance, often a couple of degrees or a few percent.
  • Aim at your own forehead or palm from a short distance. Skin surface usually reads in the low to mid 30s C.
  • Compare a painted wall with a contact thermometer taped to it for a few minutes.

Allow the camera to warm up for several minutes first. Thermal cameras perform periodic shutter corrections, the soft click you hear, and readings settle once the internal temperature stabilises.

When a reset will not help

Some symptoms are hardware or calibration problems, and no menu option fixes them:

  • Readings off by the same large margin on every surface, even with correct emissivity. That suggests calibration drift and needs a service centre calibration.
  • Dead pixels, lines or a blotchy image that remain after a shutter correction. The detector or its electronics may be damaged.
  • The camera will not boot at all, loops at the logo, or will not charge. Try a different charger and cable first, then contact support.
  • Cracked or fogged lens. Germanium lenses are delicate. Moisture inside the housing is a seal failure.

If your unit is within warranty, opening it yourself usually voids cover, so contact the manufacturer before attempting any repair. For a camera used on electrical panels, a failed self-test or erratic readings is reason to stop using it for safety decisions until it has been checked, because an imager that reads cold over a hot connection gives false reassurance. A thermal camera only reads surface temperature, as explained in can a thermal camera see through walls, so it never replaces proper isolation and testing.

Start with the gentlest fix

Copy your images to a computer, try a forced restart, and only then use the factory default option in Device settings or the app. Finish by checking the camera against iced water and a painted wall, and if it is still wrong by the same margin everywhere, book a calibration rather than resetting again.

Frequently Asked Questions

Will a factory reset delete my thermal images?

It depends on the model and the exact reset chosen. Settings resets usually leave images in place, while some full resets or storage formats remove them. Always copy images off before you start.

Does a factory reset recalibrate the camera?

No. Radiometric calibration lives in protected memory and is not touched by a user reset. Only a calibration service with temperature references can correct calibration drift.

My FLIR One shows a blank or frozen image. What should I try?

Unplug it, force close the app, charge the attachment fully, and reconnect with the phone case removed so the connector seats properly. Reinstalling the app fixes many connection problems.

Why are temperatures wrong after a reset?

The reset restored default emissivity and reflected temperature, which may not match what you are measuring. Re-enter the correct emissivity for the surface, especially for metals, and the readings should return to normal.

Should I update the firmware instead of resetting?

If the problem is a known bug such as Wi-Fi drops or menu crashes, an update is often the better fix. Do it with a full battery and follow the manufacturer's instructions exactly.