How to Fix the Carbon Monoxide Sensor on a Predator Generator

Your Predator generator keeps cutting out and the CO indicator is lit, or it will not stay running at all. Before you look for a way around the sensor, find out whether it is protecting you or genuinely broken.

As an Amazon Associate, Akermin earns from qualifying purchases. Product links on this page are affiliate links.

In most cases the carbon monoxide sensor is not broken: it has shut the engine down because exhaust gas is building up around the generator, usually from running it in a garage, under a porch, against a wall or with the wind blowing the exhaust back over the unit. Move the generator into open air, at least 20 feet from any building with the exhaust pointing away, let the area air out, and restart. If it still shuts off in wide open air, or the indicator shows a sensor fault, the module or its wiring needs inspection or warranty service, and the one thing you should never do is disconnect or bypass it.

What the CO shutoff on the generator actually does

Many recent Predator models carry a carbon monoxide shutoff system, marketed as CO SECURE. A small electrochemical or similar CO sensor sits in the generator housing and samples the air around the engine. When carbon monoxide around the unit climbs past a built-in limit, or rises quickly, the control module grounds the ignition and the engine stops. An indicator light on the panel tells you the stop was caused by CO rather than by low oil or an overload.

This feature exists because portable generators are one of the most common sources of fatal CO poisoning in homes. A gasoline engine produces a large amount of carbon monoxide, and in an enclosed or semi-enclosed space it can reach dangerous levels within minutes. Industry safety standards for portable generators now expect a CO shutoff for exactly this reason.

Two limits matter. The sensor only protects the space around the generator; it says nothing about the air inside your house, where exhaust can drift through windows, vents and door gaps. And it is not a measuring instrument with a readout; it is a trip switch. The difference between a trip device and a true meter is explained in the comparison of a carbon monoxide meter and a CO alarm.

Why the sensor keeps shutting the engine off

Cause How to recognise it Fix
Running in a garage, shed, carport or under an overhang Trips within minutes; any roof or three walls around the unit Move fully outdoors, never in an attached or open garage
Exhaust blowing back onto the unit Trips only on certain days or when the wind shifts Turn the generator so the muffler points downwind and away from walls
Too close to a wall, fence or vehicle Trips in still air; exhaust has nowhere to disperse Give it clear space on all sides, at least 20 feet from the house
Low spot, pit or enclosure Unit sits in a hollow, a box or a homemade rain shelter Use an open, level spot; only use covers designed for running generators
Engine running rich Black smoke, fuel smell, rough idle, choke left on Open the choke fully once warm; clean the air filter and carburetor
Sensor or wiring fault Trips in open air on a breezy day; fault pattern on the indicator Inspect the connector, then arrange warranty or shop service

The rich-running cause is easy to miss. A choke left partly closed, a clogged air filter or a carburetor with stale fuel varnish all raise the CO content of the exhaust, so a generator that used to run fine in the same spot can start tripping. Fixing the engine fixes the trips.

Step-by-step: clearing the shutdown safely

  1. Leave the area first. If the generator stopped in or near an enclosed space, step out into fresh air and ventilate the space before you go back. The shutoff means CO built up there.
  2. Read the indicator. Note whether the CO light is solid or flashing and whether the oil or overload light is also on. Your owner’s manual lists what each pattern means for your model, including the pattern that indicates a sensor fault rather than a CO trip.
  3. Relocate the generator. Put it on open, level ground at least 20 feet from the house, away from windows, doors and vents, with the exhaust pointing away from the building and from where people stand.
  4. Wait before restarting. Give the area several minutes to clear. Some models hold the shutdown state until the engine switch is cycled off and back on.
  5. Check the engine. Confirm the choke is fully open once the engine is warm, the air filter is clean, and the fuel is fresh. A rich mixture is a CO problem the sensor is right to catch.
  6. Inspect the sensor area. With the engine off and cool, look at the sensor housing and the vent openings near it for mud, spider webs, sawdust or water. Make sure the wiring connector to the module is seated and not corroded. Do not open sealed modules.
  7. Restart and watch. Run it in the new spot for a while. If it now runs normally, the cause was placement or the engine, not the sensor.

Checking whether the sensor is honest

If you want evidence rather than guesswork, a portable CO meter tells you what concentration the generator is actually sitting in. A pocket instrument such as the NIST-calibrated carbon monoxide meter, which reads 0 to 1000 ppm with 1 ppm resolution, can be placed a few feet from the generator, upwind of the exhaust and roughly where the unit’s own sensor sits. Keep it out of the direct exhaust stream, which is far more concentrated than the air the sensor samples.

  • If the meter shows high and rising readings near the generator before it trips, the sensor is working and the location is the problem.
  • If the meter stays near zero in open, moving air and the generator still trips repeatedly, suspect the sensor module or its wiring.
  • If the meter shows elevated CO inside the house while the generator runs outside, move the generator further away or change the exhaust direction immediately, and keep a CO alarm running indoors.

The guide on how to choose a carbon monoxide meter covers the features that matter for this kind of spot check, such as a peak reading and a fast response time.

When it is a real fault, and why bypassing it is a bad idea

The sensor module can fail. Water intrusion, a cracked housing after a fall, a broken wire, or a sensor at the end of its life can all cause trips in clean air or a fault indication. When that happens:

  • Use the warranty. Generators of this kind usually carry a manufacturer warranty, and the CO system is part of it. The retailer or an authorized service center can test the module and replace it if needed.
  • Use a small-engine shop if the warranty has ended. A replacement module is a modest part, and the shop can also check that the engine is not running rich.
  • Do not cut, unplug or jumper the sensor. Disabling it removes the only automatic protection the generator has, can void the warranty, and can create liability if someone is harmed.

Regardless of the sensor, never run a portable generator indoors, in a garage even with the door open, in a basement, or in a crawl space. Run working CO alarms with battery backup inside the home on every level and near sleeping areas while the generator is in use; the roundup of carbon monoxide detectors covers suitable options. If anyone develops headache, dizziness, nausea, confusion or sleepiness while a generator is running, get everyone into fresh air at once and call emergency services.

Try the open-air test today

Take the generator to the most open spot you have, point the exhaust downwind, open the choke fully once it is warm and let it run under a light load for half an hour. If it stays running, you have found your answer and should keep that setup; if it trips there, note the indicator pattern and take it in for warranty service with the sensor intact.

Frequently Asked Questions

Can I disable the CO sensor on my Predator generator?

It is physically possible on some models, but it is unsafe and not recommended. The sensor exists because generator exhaust kills people every year, and removing it can also void your warranty. Fix the placement, the engine tuning or the faulty module instead.

Why does my generator trip the CO sensor outside?

Outside does not always mean open air. Walls, fences, parked cars, a covered patio or a still day can trap exhaust around the unit, and wind can push the exhaust back over the sensor. A rich-running engine also makes more CO. If none of these apply, the sensor may be faulty.

How far from the house should a generator be?

Public safety guidance generally says at least 20 feet from the home, with the exhaust pointed away from windows, doors and vents. Further is better if you have the space. Distance alone does not guarantee safety, so keep CO alarms working inside.

Does the generator CO sensor protect the inside of my house?

No. It only senses the air around the generator and shuts the engine down when CO builds up there. Exhaust can still enter the house through openings, so you need separate CO alarms inside, on each level and near bedrooms.

Will a new spark plug or carburetor cleaning stop CO trips?

It can, if the engine was running rich. A clogged air filter, a partly closed choke or a gummed carburetor raises carbon monoxide in the exhaust. If tuning the engine does not help and the trips happen in open air, look at the sensor module.