Start with the lights and sounds, then the number. A green light means powered and normal; a red light with a loud repeating alarm means it has detected carbon monoxide or combustible gas and you should leave and call for help from outside; an amber or yellow light with chirps usually means a fault, low battery or end of life. The display number is carbon monoxide in parts per million (ppm): zero is normal indoors, persistent single-digit or low double-digit readings mean a source worth finding, and readings in the tens and above mean ventilate and investigate now. Combustible gas is usually shown as an alarm or a percentage of the lower explosive limit, not as ppm.
Two gases, two sensors, one housing
A combination detector holds two separate sensors that work in different ways and watch for different dangers.
- Carbon monoxide is a toxic gas produced by incomplete burning in furnaces, boilers, water heaters, stoves, fireplaces, generators and vehicles. It has no smell. An electrochemical cell produces a small current proportional to its concentration, which is why the detector can display a number in ppm.
- Combustible or explosive gas means natural gas (mostly methane) or propane leaking from pipework, appliances or cylinders. It is detected by a heated catalytic or semiconductor sensor, and the danger is fire or explosion, not poisoning. Its alarm level is set well below the concentration at which the gas could ignite.
A plain CO alarm cannot detect natural gas or propane, and a plain gas detector cannot detect CO; the explanation of whether a CO detector detects natural gas covers why, and the comparison of a gas leak detector and a CO detector shows which homes need which. Check the label to be sure your unit has both sensors before relying on it for both.
Reading the lights, sounds and display
| What you see or hear | Usual meaning | What to do |
|---|---|---|
| Steady or blinking green light | Powered and working normally | Nothing |
| Red light, loud repeating pattern, often four beeps then a pause | Carbon monoxide alarm | Leave, call emergency services from outside |
| Red light with a different alarm pattern or a voice saying gas or explosive | Combustible gas alarm | Leave without touching switches; call the gas utility or emergency services from outside |
| Single chirp every minute or so | Low battery | Replace or charge the battery |
| Amber light, error code, or end-of-life chirp or message | Fault or sensor expired | Reset per manual; replace the unit if it persists |
| Number on display, no alarm | Measured CO in ppm below the alarm point | Note it; see the reading bands below |
| PEAK or memory value | Highest CO measured since last reset | Read it after any event, before you reset |
Patterns differ between makers, so the label on the back and the manual are the final word. Voice models help: some announce the gas type so you are not left guessing.
Not every display shows every reading. Many home alarms do not show values until CO reaches a few tens of ppm, to avoid alarming people about trivial levels. Low-level monitors are made to show smaller numbers: the Fast low level CO monitor displays from 10 ppm and sounds its buzzer at 25 ppm, while the Kidde Smart CO and air quality detector gives an earlier warning pattern at 30 to 70 ppm and a separate alarm from 70 ppm.
What the CO number means
Home CO alarms are deliberately time-weighted. In North America, under the UL 2034 standard, they must sound within about one to four hours at 70 ppm, within about 10 to 50 minutes at 150 ppm, and within a few minutes at 400 ppm. That is why a display can show a number for a while before the alarm sounds.
| Reading (ppm) | What it suggests | Action |
|---|---|---|
| 0 | Normal clean indoor air | None |
| 1 to 9, brief | Short spikes from cooking, a lit fireplace or traffic | Ventilate if it lingers |
| Above 9, recurring | A source is adding CO; outdoor air quality standards use 9 ppm over eight hours as a limit | Find the source; have appliances inspected |
| 35 and above | NIOSH’s recommended workplace exposure limit over a work shift is 35 ppm | Ventilate, turn off fuel-burning appliances, investigate now |
| 70 and above, sustained | Home alarm range | Leave, call emergency services |
| Any level with headache, dizziness, nausea, confusion | Possible CO poisoning | Leave immediately, seek medical help |
Professional meters work similarly but give more control. The Klein Tools ET110 CO meter, for instance, has low and high alarms at 35 and 200 ppm and a short-term exposure limit alarm, which suits technicians checking appliances. The difference between a meter and an alarm is set out in CO meter vs CO alarm.
Reading the combustible gas side
Explosive gas readings work differently. Natural gas and propane can only ignite when mixed with air within a certain range. The bottom of that range is the lower explosive limit (LEL): about 5 percent by volume for methane and about 2 percent for propane. Home gas alarms are designed to sound at a fraction of the LEL, commonly no more than a quarter of it, so you have warning well before an ignitable mixture forms.
- Some units show no number for gas, only an alarm. Others show a percentage of LEL, where 10 means one tenth of the way to the explosive limit, not 10 percent gas.
- Natural gas is lighter than air and collects high; propane is heavier and collects low. Detector placement should match the gas, as the manual explains.
- Utilities add a sulphur-smelling odorant to gas. If you smell rotten eggs, treat it as a leak even if the detector is silent.
On any gas alarm or smell: do not switch lights or appliances on or off, do not use phones inside, do not light anything. Leave the building, leave doors open as you go, and call the gas utility or emergency services from a safe distance outside.
Checking the detector itself is working
- Press test monthly. This confirms the horn, lights and electronics work. It does not prove the sensors still respond to gas.
- Check the date. Look for the manufacture or replace-by date on the back. CO sensors typically last seven to ten years; gas sensors have their own life listed in the manual.
- Watch for end-of-life signals, which sound different from a low battery.
- Keep it clear. Dust, paint, cleaning sprays and hairspray can foul sensors. Do not paint over or enclose the unit.
- Compare, if in doubt. If you suspect it is under-reading, a calibrated portable CO meter or the fire department’s instrument will tell you. Gas sensors can be checked by a gas utility technician.
A detector warns; it does not fix the source. Any confirmed CO or gas reading needs a licensed heating or gas technician to find and repair the cause before the appliance is used again.
Check your detector’s label now
Turn the detector over today and read three things on the label: which gases it detects, what each alarm pattern sounds like, and its replace-by date. Press the test button, note whether it has a peak memory, and save the manual’s signal table on your phone so you can identify any future alarm in seconds.
Frequently Asked Questions
What does PEAK mean on a CO detector?
It is the highest carbon monoxide concentration the unit has measured since it was last reset. Check it after any alarm or reading, and tell responders or your heating technician. Resetting clears it.
What is a dangerous CO level on my detector?
Readings that keep returning above a few ppm need investigating, sustained readings of 35 ppm and above need prompt action, and alarm-level readings around 70 ppm and above mean leave and call for help. Symptoms at any level mean get to fresh air.
Why does my CO detector show 0 all the time?
Clean indoor air should read zero, and many home alarms do not display anything below a few tens of ppm. Zero usually means no significant CO. Press test to confirm the unit is working, and check its expiry date.
Does a CO alarm detect gas leaks?
A CO-only alarm does not detect natural gas or propane. You need a combination unit with an explosive gas sensor, or a separate gas detector. Check the label for both gases.
What does LEL mean on a gas detector?
LEL is the lower explosive limit, the lowest gas concentration in air that can ignite. A reading in percent LEL shows how close the air is to that limit, so 10 percent LEL is one tenth of the way there.