As an Amazon Associate, Akermin earns from qualifying purchases. Product links on this page are affiliate links.
On a rechargeable or serviceable monitor, press and hold the power button, usually the main or only button, and keep holding through the on-screen countdown until the display goes blank; letting go early cancels the shutdown. Many disposable single-gas H2S clip monitors have no off function at all: they are designed to run continuously for their whole life, and the only way to stop them is to let them expire or, on some models, put them in a hibernation case. If a unit that should turn off refuses, its settings may be locked to always-on by whoever manages the fleet.
First, work out which kind of monitor you are holding
Hydrogen sulfide monitors fall into two families, and the off procedure is completely different between them.
| Type | How to recognise it | Can it be turned off? |
|---|---|---|
| Disposable single-gas clip monitor | Small, sealed case, no charging port or battery door, often a countdown of months or days remaining on screen | Usually no. Runs continuously until end of life |
| Serviceable single-gas monitor | Replaceable battery or charging port, sensor can be replaced | Yes, long press of the power button |
| Multi-gas monitor (H2S plus O2, CO, LEL) | Larger, several gas readings on screen, charging contacts or USB port | Yes, long press, sometimes with a confirm step |
A disposable clip monitor is sold with a fixed operating life. The manufacturer seals in a battery sized to last that whole period with the unit always on, and removing the off switch prevents the most dangerous failure in gas detection: a worker forgetting to turn the monitor back on before entering a sewer, tank or well site. A monitor that cannot be off cannot be off by mistake. If yours shows a number of months or days on the display, that is usually remaining life, not a setting.
Multi-gas units like the MSA ALTAIR 4XR or a compact 4 gas monitor are rechargeable and are meant to be switched off and docked or charged between shifts.
Turning off a serviceable or multi-gas monitor
The exact button name varies, but the pattern is almost universal across brands.
- Move to clean air. Some units will not shut down while in alarm, and you should not shut one off while it is alarming anyway. If it is alarming, leave the area first.
- Acknowledge any alarm or warning on screen with a short press, if it lets you.
- Press and hold the power button. On single-button designs this is the only button. On multi-button designs it is usually marked with a power symbol or is the largest button.
- Keep holding through the countdown. Most monitors show a short countdown or a word like OFF or SHUTDOWN and beep each second. Release before it finishes and it stays on. This delay is deliberate, so a bump against your belt does not switch it off.
- Confirm if asked. Some models ask you to press a second button to confirm.
- Check the screen is blank and no LEDs flash. Some units flash a slow confidence beacon even when on, so blank means off.
- Dock or charge it. Many units turn on automatically or wake briefly when placed in a charger or a bump-test dock. That is normal.
If a short press does nothing, it is often working correctly, because a short press usually means acknowledge, backlight or show peak readings.
Why it will not turn off, and what each cause looks like
| Symptom | Likely cause | What to do |
|---|---|---|
| No response to a long press, display shows months or days | Disposable clip monitor with no off function | Store it, or use a hibernation case if the maker offers one |
| Countdown starts then aborts | Button released too early, or monitor in alarm | Hold longer in clean air |
| Message such as locked or always on | Fleet configuration set by safety manager to prevent shutdown | Ask the person who configures the monitors; it is intentional |
| Turns off then restarts in the charger | Charging or dock wakes it | Normal behaviour |
| Frozen screen, no buttons respond | Firmware hang or very low battery | Charge it; if it still freezes, send it for service |
On company-owned fleets, the always-on setting is common in confined-space and oil and gas work. Do not try to bypass it. Read the reasoning on why gas detector sensors do not last forever and you will see why disposables are built this way.
Storing a monitor that cannot be switched off
If you have a disposable clip monitor that you will not use for a while, you have a few honest options.
- Hibernation case. Some disposable designs can be put into a hibernation or storage mode with a special case or accessory, which pauses the life countdown. Check the manual for your exact model before assuming this exists.
- Put it somewhere it will not bother anyone. It will keep running and the battery will keep counting down. A sealed drawer does not hurt it, but do not store it near solvents, silicone sprays or cleaning chemicals, which can poison electrochemical sensors.
- Plan for the end date. When the remaining life runs out, the monitor stops and must be recycled through electronics recycling. It cannot be recharged or reset.
Never wrap a monitor in tape or foil to silence it. If it is chirping, it is telling you something: low life remaining, a missed bump test, or a real reading. Covering the sensor opening blocks gas from reaching it and turns a safety device into a dangerous one if someone later picks it up and wears it.
Before you turn it back on: bump test and safety limits
When a serviceable monitor comes back on, it runs a self-test and a warm-up. Wait for it to finish and show zero, or a stable low reading in clean air, before you rely on it. Many employers require a bump test before each day’s use, exposing the sensor to a known gas to prove it alarms. See why gas detectors need bump tests and calibration for the difference between the two.
Hydrogen sulfide is serious. At low concentrations it smells of rotten eggs, but at higher levels it deadens the sense of smell, so you cannot rely on your nose. Typical personal monitors have a low alarm around 10 ppm and a high alarm around 15 or 20 ppm, though the exact setpoints are configured by the employer. Concentrations in the hundreds of ppm can cause rapid collapse. If a monitor alarms, leave the area upwind and do not re-enter to retrieve anyone without proper breathing apparatus and rescue training. If you are seeing readings you do not trust, the causes of false gas detector readings are worth ruling out before blaming the sensor.
Turning a monitor off is fine at the end of a shift. Turning it off because it keeps alarming is not. Get it checked, calibrated or replaced instead.
If it still will not shut down
Look at the display for a remaining-life counter and check the label or manual for the words disposable or two-year; if you find either, the monitor is working as designed and simply runs until it expires. If it is a rechargeable unit that will not respond to a long hold in clean air, charge it fully and try again, then contact whoever services your fleet.
Frequently Asked Questions
Can I take the battery out of a disposable H2S monitor?
No. The battery is sealed inside, and opening the case destroys the unit's water and dust protection and its certification. Let it run to the end of its life and recycle it.
Does turning an H2S monitor off reset the peak reading?
On many monitors the peak or event log is stored in memory and survives a power cycle, so a supervisor can still see exposures. Check the manual if you need to clear or download the log.
Why does my monitor keep beeping once a minute?
A slow regular beep is usually a confidence signal showing the unit is on, or a reminder that a bump test or calibration is overdue. A fast, loud, continuous alarm is a gas alarm and means leave the area.
Will a monitor detect H2S while it is booting up?
Not reliably. During warm-up and self-test the sensor is stabilising, so wait until the startup sequence completes before entering any area where H2S may be present.
Is it safe to store an H2S monitor in a vehicle?
Short periods are usually fine, but very hot or freezing cabins can shorten sensor and battery life and may push the unit outside its rated operating temperature. A temperate indoor shelf is better.