As an Amazon Associate, Akermin earns from qualifying purchases. Product links on this page are affiliate links.
A thermal imaging device detects infrared radiation, the invisible heat energy every object gives off, and turns it into a picture where each pixel represents surface temperature. That lets it reveal warm and cold patterns: missing insulation, draughts, hot electrical connections, warm pipes in a floor, wet patches cooled by evaporation, overheating motors, and people or animals in the dark. It does not see through walls, glass or water, it does not detect gases or moisture directly, and shiny surfaces can fool it with reflections. Everything it shows is the temperature of the first surface it looks at.
What the detector is actually sensing
Every object warmer than absolute zero gives off infrared radiation, and the amount rises steeply with temperature. Handheld thermal cameras use a grid of tiny sensors called a microbolometer, tuned to long-wave infrared at roughly 8 to 14 micrometres, the band where objects at everyday temperatures emit most strongly and where air is fairly transparent. Each sensor element warms slightly when infrared reaches it, its electrical resistance changes, and the camera converts that into a temperature and a colour. Our explainer on how a thermal camera sees heat goes deeper into the electronics.
Two properties of the surface affect what the camera reads. Emissivity is how efficiently the surface radiates. Paint, wood, brick, skin and water radiate well, so the camera reads them accurately. Polished metal radiates poorly and instead reflects infrared from its surroundings like a mirror. Our page on emissivity in thermal imaging explains how to correct for it.
What a thermal camera can reveal, and what it cannot
| Target | Detects it? | How it shows up |
|---|---|---|
| Missing or slumped insulation | Yes, with a good indoor to outdoor temperature difference | Cold patches on inside walls and ceilings in winter |
| Draughts and air leaks | Yes | Cold streaks fanning out from gaps around windows, doors and skirting |
| Hot electrical connections and overloaded breakers | Yes, when the circuit is carrying load | One component noticeably warmer than identical neighbours |
| Hot water and heating pipes under floors | Yes, while hot water is flowing | Warm lines across the floor surface |
| Water leaks and damp | Indirectly | Cooler patches from evaporation, or warm trails from hot water leaks; must be confirmed with a moisture meter |
| People and animals | Yes, including in darkness | Warm shapes against a cooler background |
| Mice, birds or wasp nests in cavities | Sometimes | Warm spots on the wall or ceiling surface |
| Objects behind a solid wall | Only if they change the surface temperature | Studs, pipes and cables may show as faint lines |
| Anything behind glass | No | Glass blocks long-wave infrared; you see the glass surface and reflections |
| Gas leaks | No, with ordinary cameras | Specialised optical gas imaging cameras are needed |
The pattern in that table is the key point: a thermal camera detects differences in surface temperature. When a hidden problem changes the surface temperature, it can show up. When it does not, the camera sees nothing, which is covered in our page on whether thermal cameras see through walls.
Getting useful detections in practice
- Create a temperature difference. Insulation and draught checks work best when inside and outside differ by a large margin, such as a cold morning with the heating on.
- Add load or flow. Electrical faults appear only when current flows, and pipe runs only when hot water runs. Turn on appliances or the hot tap first.
- Stand at an angle to shiny surfaces. If a hot spot moves when you move, it is a reflection, often of you.
- Get close enough. Small targets need several pixels across them to measure correctly. Our guide to thermal camera resolution shows how resolution and distance interact.
- Set the span. Narrow the temperature range on the display so small differences show as distinct colours rather than one blur.
- Confirm with another tool. A moisture meter confirms damp, a clamp meter confirms electrical load, and a contact probe confirms an exact temperature.
How to check what you are seeing is real
A simple validation tells you whether readings make sense. Aim at a glass of ice water and at a mug of hot water side by side; the ice water should read near freezing and the hot water should read high and fall as it cools. Then touch a wall for a few seconds and image it; your handprint will glow briefly, which shows how sensitive the camera is to small changes. That sensitivity is described by the camera’s NETD figure, and lower values pick up finer differences.
Before deciding that a cold patch is damp or a warm spot is a fault, ask whether something ordinary explains it: a radiator on the other side of the wall, a sunlit area, furniture that blocked heat, or a reflection from a window.
Colour palettes can also mislead. The camera assigns colours to the temperature span on screen, so a patch that looks alarmingly white or red on auto-range might be only a degree warmer than its surroundings. Check the scale bar at the side of the image, or lock the span manually, before deciding anything is hot. A dramatic image on a narrow span and a dull image on a wide span can show exactly the same scene.
Distance and angle matter as well. Readings taken at a steep angle to a surface tend to read lower than the true temperature because less radiation reaches the lens and more is reflected. Stand as square on to the surface as you safely can, and move closer for small targets rather than relying on digital zoom, which enlarges pixels without adding detail.
Choosing a device for what you need to detect
Phone-attached cameras like the TopDon TC002C Duo suit draught hunting, radiator checks and spotting warm pipes. Standalone handhelds such as the MiLESEEY TR20 are easier to use on ladders and in lofts. For electrical and commercial building work, a professional imager such as the FLIR E6 Pro adds the reporting and image quality that clients expect. Whatever the device, it will not detect carbon monoxide, smoke, gas leaks or radon; those need dedicated detectors.
Safety matters around electrical findings. If a breaker, socket or connection looks clearly hotter than its neighbours, stop using that circuit and call a licensed electrician. Do not remove panel covers to get a better image unless you are qualified to work near live parts.
Try this first
Pick one real question, such as which room loses most heat or why one radiator stays cold, and wait for conditions that create a clear temperature difference. Image the area with a normal photo alongside each thermal shot, check reflections by changing angle, and confirm anything suspicious with a moisture meter or contact thermometer before acting on it.
Frequently Asked Questions
Can a thermal imaging device detect moisture?
Not directly. Wet materials often look cooler because water evaporates and cools the surface, so a thermal camera can point to suspect areas. A moisture meter is needed to confirm the material is actually wet.
Can thermal cameras see through clothing or walls?
No. They read the temperature of the outer surface. Clothing and walls may show faint patterns from what is behind them only when that changes the surface temperature.
Does a thermal camera work in complete darkness?
Yes. It detects heat given off by objects rather than reflected visible light, so it works the same day or night. Fog, heavy rain and steam reduce its range.
Can a thermal camera detect a gas leak?
Ordinary thermal cameras cannot see natural gas or refrigerant. Specialised optical gas imaging cameras tuned to particular gases exist for industry. For homes, use a gas detector and call the gas emergency line if you smell gas.
Why does glass look like a mirror on a thermal camera?
Glass is opaque to long-wave infrared and reflects it well, so you see reflected heat from the room and yourself rather than what is behind the window.