Skip to content
AkerminMeasure. Monitor. Improve. Compare Products
Learning Center

Does a Psychrometer Measure Humidity?

You have seen a psychrometer in an HVAC kit or a science lab and wonder whether it truly measures humidity or just temperature. It does both, in a clever indirect way, and knowing how it works helps you trust or question the result.

As an Amazon Associate, Akermin earns from qualifying purchases. Product links on this page are affiliate links.

A psychrometer does measure humidity, but indirectly. It reads two temperatures, a normal dry bulb and a wet bulb covered by a damp wick, and the gap between them depends on how quickly water can evaporate into the air. Drier air cools the wet bulb more, so a larger difference means lower humidity, and a table, chart or built-in calculator converts the pair into relative humidity and dew point.

Why a wet thermometer reveals how dry the air is

When water evaporates it takes heat with it. Wrap a thermometer bulb in a wick soaked with clean water and move air across it, and evaporation cools the bulb below the air temperature. How much it cools depends on how much more water vapor the air can accept. In dry air evaporation is fast and the wet bulb drops a long way. In humid air evaporation is slow and the wet bulb stays close to the dry bulb. At 100 percent relative humidity, nothing evaporates and the two readings match.

The difference between the two is called the wet bulb depression. Combined with the dry bulb temperature and, for best accuracy, the air pressure, it fixes the exact amount of water vapor in the air. From that, relative humidity and dew point follow. The physics has been understood for a very long time, which is why psychrometers have long served as a reference method for checking other humidity instruments.

The key requirement is airflow. A wet bulb sitting in still air surrounds itself with a pocket of moist air, evaporates less, and reads too high, which makes humidity look higher than it is. A sling psychrometer solves this by whirling the thermometers by hand. An aspirated psychrometer uses a small fan to pull air steadily across the wick.

A worked example with real numbers

Suppose a sling psychrometer at sea level reads a dry bulb of 25 degrees C and a wet bulb of 20 degrees C, a depression of 5 degrees.

  1. The saturation vapor pressure at the wet bulb temperature of 20 degrees C is about 2.34 kPa.
  2. The psychrometer equation subtracts a term for the cooling: roughly 0.067 kPa per degree of depression at sea level pressure, so 5 times 0.067 is about 0.34 kPa.
  3. Actual vapor pressure is therefore about 2.34 minus 0.34, which is 2.00 kPa.
  4. Saturation vapor pressure at the dry bulb temperature of 25 degrees C is about 3.17 kPa.
  5. Relative humidity is 2.00 divided by 3.17, which is about 63 percent.
  6. The temperature where saturation vapor pressure equals 2.00 kPa is about 17.5 degrees C, which is the dew point.

You do not need to do this by hand. Printed psychrometric tables and charts give the answer from the two readings, and digital units calculate it instantly. Our guide on calculating dew point from temperature and humidity explains the dew point step in more detail, and why dew point matters indoors explains what to do with it.

Psychrometer versus electronic hygrometer

Feature Sling or aspirated psychrometer Capacitive digital hygrometer
What it senses Two temperatures, humidity calculated Capacitance of a humidity-sensitive film
Drift over time Little, if thermometers are good and the wick is clean Sensors can drift, especially after high humidity or contamination
Speed A minute or two of slinging Continuous once settled
Best range Moderate to high humidity, above freezing Wide range, including low humidity
Common errors Dirty or dry wick, too little airflow, misreading thermometers Sensor offset, slow response after moving rooms
Logging No Often yes

One point surprises many buyers. Many handheld instruments sold as digital psychrometers have no wet wick at all. The YT606 temperature humidity meter, for example, uses a semiconductor humidity sensor, and units such as the ERAY digital psychrometer display wet bulb and dew point alongside relative humidity; meters of this kind typically calculate those values from an electronic sensor reading. They give the same outputs an HVAC technician expects from a psychrometer, but they are measuring humidity with a sensor, not with a wet wick. That is not a flaw, just a different method with different strengths.

Getting an accurate reading from a wet and dry bulb

  • Use distilled water on the wick. Minerals from tap water build up and slow evaporation.
  • Keep the wick clean and fully wet. Replace it when it discolors or stiffens. A dry patch makes the wet bulb read high.
  • Give it enough airflow. Sling briskly or let the aspirator run until the wet bulb stops falling, then read it immediately.
  • Read the wet bulb first, as it starts warming as soon as airflow stops.
  • Stay out of direct sun and away from your body heat and breath.
  • Take two or three readings and use the lowest stable wet bulb value.
  • Below freezing the wick ices over and the method gets awkward; electronic sensors are usually more practical then.

Our step-by-step guide on how to use a psychrometer walks through the slinging technique and reading the chart.

Using a psychrometer to check other humidity meters

Because a well-maintained psychrometer relies on temperature, which is easy to measure accurately, it is a handy cross-check for room hygrometers. Take a careful psychrometer reading in a stable room, then compare it with your digital hygrometer placed nearby for at least half an hour. A difference of a few percent is common and usually within the hygrometer’s specification. A large difference, especially one that stays after repeated checks, means the hygrometer needs an offset or replacement. The salt test in our guide on calibrating a hygrometer gives a second, independent check.

If the two thermometers on a psychrometer disagree when both are dry, the instrument itself is off. Check them side by side before wetting the wick; any difference adds directly to the depression and throws off the humidity result.

There is a practical HVAC use as well. Taking wet and dry bulb readings at the return grille and again at a supply register shows how much the air conditioner is cooling and drying the air. The wet bulb drop reflects the total heat the coil removes, and the dew point drop, worked out from each pair of readings, shows how much moisture it removes. Very little dew point drop across a running coil suggests it is doing mostly sensible cooling, which can point to airflow that is too high or a coil that is running warm. Technicians use those readings, together with refrigerant pressures and the manufacturer’s charging charts, to judge whether a system is working properly. A homeowner can take the same readings out of curiosity, but charging and refrigerant work need a licensed technician.

Finally, keep the psychrometer itself in good condition. Glass thermometers can develop a separated column of liquid after a knock, which makes them read wrong without any obvious sign; inspect the column before each use. On digital psychrometers, protect the sensor from dust and condensation, and store the unit in a dry case.

Take your first reading

Wet the wick with distilled water, check that both thermometers agree while dry, sling or aspirate until the wet bulb stops dropping, then look up the humidity from the depression and compare it with any hygrometer in the room to see how far that one has drifted.

Frequently Asked Questions

What is a good wet bulb depression?

There is no good or bad value; it simply reflects the humidity. A small depression of one or two degrees means very humid air, while a large one of ten degrees or more means dry air.

Why do I need air pressure for a psychrometer reading?

The cooling term in the psychrometer equation depends slightly on atmospheric pressure. At high altitude the result changes, so use tables or settings for your elevation when accuracy matters.

Can a psychrometer measure humidity in a duct?

Yes, if the airflow across the wick is sufficient and the thermometers can be placed in the air stream. HVAC technicians often take wet and dry bulb readings at supply and return to check cooling performance.

Is a sling psychrometer more accurate than a digital hygrometer?

A carefully used psychrometer can be very accurate and does not drift like an electronic sensor. In practice, user technique decides the result, so a good digital meter may be more consistent for casual use.

What does wet bulb temperature tell an HVAC technician?

It reflects the heat content of the air, which matters for sizing cooling, checking superheat targets on some systems, and judging whether a coil is removing moisture.