Skip to content
AkerminMeasure. Monitor. Improve. Compare Products
Learning Center

How to Check Positive and Negative with a Multimeter

You have two unmarked wires, a power adapter, or a battery holder, and you need to know which side is positive before connecting something that cares. Or you are not sure your own meter's leads are set up the right way round.

As an Amazon Associate, Akermin earns from qualifying purchases. Product links on this page are affiliate links.

Plug the black lead into the COM jack and the red lead into the jack marked V, set the meter to DC volts, and touch the probes to the two points. If the display shows a plain number, the red probe is on the positive side and the black is on negative; if it shows a minus sign, the polarity is reversed, so the point under the black probe is positive. To confirm your meter is wired correctly, measure a battery whose markings you know. On a digital meter a reversed reading does no harm, but on an analog meter a reversed connection pushes the needle backwards against its stop.

How a meter decides what is positive

A digital multimeter measures the voltage of its red, or V, input relative to its COM input. COM is the meter’s reference, so it is treated as zero. If the red probe sits at a higher potential than the black one, the meter shows a positive number. If it sits lower, the meter shows the same magnitude with a minus sign in front. Nothing about the meter changes; the sign simply tells you which way round the probes are.

That is why the convention matters more than the colour of the leads. Black goes in COM, red goes in the V or V-ohm jack, which on most meters is also the jack for resistance, diode and continuity. A separate jack marked A or mA is for current only and must never be used for voltage. With that standard set-up, red means positive and black means negative whenever the display shows no minus sign.

Almost every modern digital meter is auto-polarity, meaning it shows the minus sign itself rather than refusing to read. If you are shopping for one, our guide to choosing a digital multimeter covers the jack layout, input protection and display features that make polarity checks easier.

Step by step: finding positive on an unknown DC source

  1. Check the leads are in the right jacks. Black in COM, red in V. Lead colours can be swapped by a previous user, so look at the jacks, not only the leads.
  2. Select DC volts. The symbol is a V with a straight line, often with a dashed line under it. On a manual-range meter, pick a range above the voltage you expect, for example 20 V for a 12 V adapter.
  3. Touch black to one point and red to the other. Hold the probes by their insulated grips, behind the finger guards.
  4. Read the sign. No minus sign means red is on positive. A minus sign means the point under the black probe is positive.
  5. Mark the positive wire with tape or a marker before you disconnect the probes, so the answer is not lost.
  6. Confirm once more by swapping the probes. The number should stay the same and the sign should flip. If the magnitude changes a lot, you may have a poor probe contact or an AC source.

This works for batteries, wall adapters, solar panels, car circuits, DC power supplies and low-voltage lighting. On a car battery, for example, red on the post marked + and black on the – post should read around 12 to 13 volts with no minus sign.

Checking your meter and leads are set up correctly

Before trusting a polarity answer on something important, prove the meter against a source you are sure of.

Test How Expected result
Known battery Red on the + end of a AA cell, black on the flat – end About 1.5 V or a little above for a fresh alkaline cell, no minus sign
Swap probes Same battery, probes reversed Same magnitude with a minus sign
Continuity of leads Continuity mode, touch the probe tips together Beep and close to zero ohms
Diode mode check Red on an LED’s longer leg, black on the shorter leg LED glows faintly or reads a forward voltage; reversed, it reads OL
Jack check Look where the black lead is plugged COM, never A or mA

If the battery test shows a minus sign with red on positive, the leads are in the wrong jacks or swapped at the probe end. If the lead check does not beep, a lead is broken inside, which can cause wrong or unstable results; our article on what continuity is and why meters beep explains this mode.

Polarity in diode and resistance modes

In diode, continuity and resistance modes the meter supplies its own small voltage through the leads. On almost every digital multimeter, the red lead is positive in these modes too. That is what lets you identify the anode and cathode of a diode or LED: with red on the anode and black on the cathode, the meter shows a forward voltage, often somewhere around 0.5 to 0.7 V for a silicon diode and higher for LEDs. Reversed, it shows OL.

Many older analog multimeters are the exception. In their ohms range, the internal battery is often connected so that the black, COM lead is the positive one. If you are using an analog meter to check a diode or a polarised capacitor, check the manual or test a diode with known markings first. Getting this wrong on an analog meter is a common reason people read diodes backwards.

Mistakes that give the wrong polarity, or damage something

  • Red lead in the current jack. Measuring voltage with the red lead in A or mA puts a near short across the source, blowing the meter’s fuse or, on unfused meters and high-energy sources, damaging the meter and causing a flash. Always check the jack first.
  • Measuring AC on DC volts. A mains or transformer AC output reads near zero or jumps around on DC, giving a meaningless sign. Household AC has no fixed positive and negative.
  • Floating or induced readings. An unconnected wire can show small random voltages of either sign, especially near mains cables. See why ghost voltage appears on a multimeter.
  • Analog meters connected backwards. The needle tries to move below zero; on sensitive ranges this can bend it. Tap the probes briefly first if you are unsure.
  • Assuming wire colours. Red and black wire colours on adapters and equipment are a convention, not a guarantee, and some cables use a striped or printed wire for positive instead. Always measure.

When the polarity check is a safety question

Polarity checks on low-voltage DC are safe for a beginner. Mains wiring is not a DC polarity question; household line and neutral are identified differently, with a properly rated tester and knowledge of the wiring, and work inside a consumer unit or socket should be left to a qualified electrician. On high-voltage DC, such as solar strings, electric vehicle packs or large battery banks, the voltage and available energy are dangerous even at the probe tips. Use a meter rated for the voltage and category, wear appropriate protection, and do not attempt it without training. A basic handheld meter such as the Klein Tools MM325 multimeter is fine for batteries, adapters and car circuits, but check its voltage and category rating before going anywhere near higher-energy sources.

Prove the meter on a AA cell first

Grab any AA battery, put red on the bump end and black on the flat end with the meter on DC volts, and confirm you see roughly 1.5 V with no minus sign. Once your meter passes that ten-second check, measure the unknown wires the same way and label the positive one with tape before you unplug anything.

Frequently Asked Questions

Which multimeter lead is positive?

With the standard set-up, the red lead in the V or V-ohm jack is positive and the black lead in COM is negative. Always check which jack each lead is plugged into rather than relying on colour alone.

What does a minus sign on my multimeter mean?

It means the point touched by the black probe is at a higher voltage than the point touched by the red probe. The polarity is reversed, but the magnitude is still correct.

Will reversing the probes damage my digital multimeter?

No. A digital meter simply shows a negative reading. Analog meters are different: reversed polarity drives the needle backwards and can damage the movement on sensitive ranges.

How do I find positive and negative on wires with no markings?

Connect the source so it is powered, set the meter to DC volts, and touch one probe to each wire. With no minus sign on the display, the wire under the red probe is positive.

Can a multimeter tell positive and negative on AC?

No, because AC reverses direction many times per second and has no fixed polarity. Identifying line and neutral on mains wiring is a separate task that should be done with suitable test equipment by someone qualified.